Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Z2 Spin Liquids and Deconfinement

    A fractionalized particle is not simply one auxiliary fermion removed from a mean-field band. It must be a physical excitation of a constrained system, and separating it from its partner must not require an energy that grows without bound. A particularly direct test is interference: a gauge charge acquires a minus sign when it goes around a Z2\mathbb Z_2 flux, or vison.

    Here we derive the constraints and strings in a local gauge model, then insert a vison into a four-site interferometer and solve the physical spectrum and time evolution exactly. The two-dimensional model explains deconfinement. The small ring calculates its charge–flux interference algebra; it does not by itself establish a thermodynamic phase.

    Preparation: Partons and Physical Constraints distinguishes an auxiliary state from its projection. The toric code supplies the electric and magnetic string algebra. We use ℏ=1\hbar=1 and lattice spacing one, with all couplings below carrying units of energy.

    A local model with physical endpoints

    Put a link qubit on each edge of a square lattice, with Pauli operators Xij,ZijX_{ij},Z_{ij}. At each vertex introduce a hard-core boson bib_i, with ni=0,1n_i=0,1. Bosons on distinct sites commute. For now they carry only emergent gauge charge, not an assigned physical spin or electromagnetic charge. Define

    Ai=∏ℓ∋iXℓ,Bp=∏ℓ∈∂pZℓ,Gi=(−1)ni+bibgAi.A_i=\prod_{\ell\ni i}X_\ell,\qquad B_p=\prod_{\ell\in\partial p}Z_\ell,\qquad G_i=(-1)^{n_i+b_i^{\mathrm{bg}}}A_i.

    The fixed integer bibg∈{0,1}b_i^{\mathrm{bg}}\in\{0,1\} denotes a background gauge charge; it is not the boson operator bib_i. Physical states obey Gi=1G_i=1. Conjugation by GiG_i changes the sign of bib_i and of every incident ZijZ_{ij}, so the combination bi†Zijbjb_i^\dagger Z_{ij}b_j is invariant. A gauge-invariant Hamiltonian is

    H=Δ∑ini−K∑pBp−h∑ℓXℓ−t∑⟨ij⟩(bi†Zijbj+bj†Zijbi),H=\Delta\sum_i n_i-K\sum_pB_p-h\sum_\ell X_\ell -t\sum_{\langle ij\rangle}(b_i^\dagger Z_{ij}b_j+b_j^\dagger Z_{ij}b_i),

    where Δ,K>0\Delta,K>0 and t,h≥0t,h\ge0. Each term commutes with every GiG_i. This number-conserving matter model is a specified effective example, not a derivation of a particular microscopic spin Hamiltonian.

    On a closed lattice each link appears twice in the product of all stars. Consequently

    ∏iGi=(−1)Nb+Nbg,Nb=∑ini,Nbg=∑ibibg.\prod_iG_i=(-1)^{N_b+N_{\mathrm{bg}}},\qquad N_b=\sum_i n_i,\qquad N_{\mathrm{bg}}=\sum_i b_i^{\mathrm{bg}}.

    A physical sector must have even total gauge-charge parity. A single mobile charge is allowed only with a compensating charge or appropriate boundary conditions. This will matter in the ring calculation.

    An open product of ZZ operators alone changes Gauss's law at its endpoints. With dynamical matter, the pair creator must include those endpoints:

    Eij(γ)=bi†(∏ℓ∈γZℓ)bj†.\mathcal E_{ij}(\gamma)=b_i^\dagger\left(\prod_{\ell\in\gamma}Z_\ell\right)b_j^\dagger.

    It commutes with all GiG_i and creates two charges when its endpoint sites are empty. Replacing one creation operator by an annihilation operator gives dressed charge transport. By comparison, a dual-lattice string

    M(γ∗)=∏ℓ crossed by γ∗Xℓ\mathcal M(\gamma^*)=\prod_{\ell\text{ crossed by }\gamma^*}X_\ell

    commutes with the Gauss constraints and flips BpB_p at its two bulk endpoints. Those endpoints are visons. A string ending at a suitable physical boundary can insert only one bulk vison; it does not violate the even-flux constraint on a closed torus.

    Deconfinement at a controlled point

    Set the background charges to zero and take t=h=0t=h=0. On the physical space, Gauss's law fixes

    ni=1−Ai2.n_i=\frac{1-A_i}{2}.

    Indeed each assignment of link XX eigenvalues fixes exactly one matter occupation configuration. This identifies the physical space with the link-qubit Hilbert space. The Hamiltonian becomes

    H=ΔNs2−Δ2∑iAi−K∑pBp.H=\frac{\Delta N_s}{2}-\frac\Delta2\sum_iA_i-K\sum_pB_p.

    This is precisely the toric-code Hamiltonian, up to a constant, with Je=Δ/2J_e=\Delta/2 and Jm=KJ_m=K. The identification is an exact constrained-Hilbert-space map, not a mean-field approximation.

    The endpoint energies follow immediately. Acting with Eij\mathcal E_{ij} on the empty-matter ground state costs 2Δ2\Delta, independent of the length of γ\gamma. A bulk vison pair costs 4K4K, independent of the length of its dual string. Separating a pair therefore adds no string tension at this point. The topological excitations are deconfined despite the impossibility of creating a single isolated bulk charge with a local operator.

    The phase extends beyond this one soluble point. For the toric-code commuting-projector Hamiltonian, sufficiently weak local bounded perturbations preserve a separated ground-state sector and its topological structure. This uses the locality and topological-order hypotheses of Bravyi, Hastings and Michalakis, arXiv:1001.0344v1, Theorem 1 and §§2.2–2.3 (PDF), rather than an extrapolation of a four-site spectrum. String operators away from the soluble point must generally be dressed by the perturbation.

    For contrast, freeze two charges and set K=t=0K=t=0 at positive hh. Minimizing the electric term requires a path of links with X=−1X=-1 connecting the charges. If their shortest lattice separation is dd, the minimum excess energy is

    Epair(d)=2Δ+2hd.E_{\mathrm{pair}}(d)=2\Delta+2hd.

    This is an exact static-charge confinement limit. It is not the potential between arbitrary screened probes when additional dynamical charge pairs may be produced. With dynamical fundamental matter, a Wilson area/perimeter label by itself is not a universal phase diagnostic.

    The classic gauge-theory discussion in Senthil and Fisher, arXiv:cond-mat/9910224v2, §III.1, Eqs. (88)–(91) and pp. 12–13 (PDF) derives the charge–vison statistical sign and the pure-gauge confinement distinction. Their coupling KK belongs to a Euclidean spacetime action. Our KK is a Hamiltonian energy, so no numerical phase boundary is transferred between them.

    The minus sign around a vison

    For a closed direct-lattice contour CC, define the spatial Wilson loop

    W(C)=∏ℓ∈CZℓ.W(C)=\prod_{\ell\in C}Z_\ell.

    On a contractible loop, internal links cancel in the product of enclosed plaquettes:

    W(C)=∏p inside CBp.W(C)=\prod_{p\text{ inside }C}B_p.

    Thus the loop is −1-1 when it encloses an odd number of visons. Ordered gauge-invariant hops of one charge around CC multiply to this loop on the subspace with that charge at the starting site. A direct electric string and a dual magnetic string anticommute when they cross once, since ZX=−XZZX=-XZ on that one link. The interference phase is therefore π\pi.

    In the untwisted toric-code order, the electric particle ee and vison mm are bosons separately, with mutual braiding phase −1-1. Their composite is a fermion:

    ϵ=e×m,θϵ=θeθmMe,m=−1.\epsilon=e\times m,\qquad \theta_\epsilon=\theta_e\theta_m M_{e,m}=-1.

    The hard-core bosonic matter above realizes the ee particle. A fermionic Abrikosov spinon in this same topological order can instead realize ϵ\epsilon, with the remaining bosonic particle obtained by attaching a vison. Calling either excitation a spinon requires an additional physical spin assignment. Our spinless gauge model does not automatically realize a spin-½ magnet per unit cell; that question belongs to symmetry fractionalization.

    Solve a vison interferometer without extra gauge states

    Take four sites labeled j=0,1,2,3j=0,1,2,3 around one ring, with link jj joining jj to j+1j+1 modulo four. Keep exactly one mobile boson and put one fixed background charge at site zero. The constraints are

    Gj=(−1)nj+δj0Xj−1Xj=1,W=Z0Z1Z2Z3.G_j=(-1)^{n_j+\delta_{j0}}X_{j-1}X_j=1, \qquad W=Z_0Z_1Z_2Z_3.

    The fixed-number unconstrained space has dimension 4×24=644\times2^4=64. Since the product of the four GjG_j is the identity in this sector, three constraints are independent. The physical dimension is eight, not 64. It contains four charge-position states in each of the two Wilson sectors.

    The calculation uses the full projector

    P=∏j=031+Gj2.P=\prod_{j=0}^3\frac{1+G_j}{2}.

    Starting from a charge at site jj and a link configuration with Z0=Z1=Z2=1{Z_0=Z_1=Z_2=1}, Z3=WZ_3=W, projection and normalization give an orthonormal basis ∣j,W⟩|j,W\rangle. The program verifies that these eight vectors resolve PP, so gauge-equivalent configurations have not been counted as extra levels.

    Set h=0h=0 and omit the constant one-particle energy Δ\Delta. In this basis the Hamiltonian is ordinary hopping with a boundary sign:

    HW=−t∑j=02(∣j+1⟩⟨j∣+h.c.)−tW(∣0⟩⟨3∣+h.c.)−KW.H_W=-t\sum_{j=0}^{2}(|j+1\rangle\langle j|+\mathrm{h.c.}) -tW(|0\rangle\langle3|+\mathrm{h.c.})-KW.

    A change of gauge moves the negative link but cannot change its product WW. With φ+=0\varphi_+=0 and φ−=π\varphi_-=\pi, the four levels are

    En,W=−2tcos⁡ ⁣(2πn+φW4)−KW,n=0,1,2,3.E_{n,W}=-2t\cos\!\left(\frac{2\pi n+\varphi_W}{4}\right)-KW,\qquad n=0,1,2,3.

    For t=1t=1 and K=0.7K=0.7, direct diagonalization of the constrained 64-state construction gives:

    Flux sectorPhysical energies, including multiplicities
    W=+1{W=+1}−2.7, −0.7, −0.7, 1.3-2.7,\ -0.7,\ -0.7,\ 1.3
    W=−1{W=-1}−0.7142135624-0.7142135624 twice; 2.11421356242.1142135624 twice

    The largest difference from the twisted-ring formula is below 3×10−15{3\times10^{-15}}. A five-site ring with different hopping, magnetic coupling and background location gives five states per flux sector and the corresponding shifted-momentum spectrum. These are exact finite-system checks, with no continuum or thermodynamic extrapolation.

    The operator X3X_3 commutes with all constraints and anticommutes with WW. It inserts the ring's vison. In a two-dimensional bulk this operation is the endpoint of a dual string; the other endpoint lies outside the interferometer. On the ring, it maps the localized state ∣0,+⟩|0,+\rangle into ∣0,−⟩|0,-\rangle.

    Now let the charge evolve for real time ss and measure the gauge-invariant occupation of the opposite site. Diagonalizing the two four-state hopping matrices gives

    P2,+(s)=sin⁡4(ts),P2,−(s)=0.P_{2,+}(s)=\sin^4(ts),\qquad P_{2,-}(s)=0.

    For zero flux the amplitude is [cos⁡(2ts)−1]/2[\cos(2ts)-1]/2. For π\pi flux, the two equal-length paths to site two cancel. Equivalently, the W=−1{W=-1} kinetic matrix obeys Hkin2=2t21H_{\mathrm{kin}}^2=2t^2\mathbf1, while both the identity and HkinH_{\mathrm{kin}} have zero matrix element from zero to two. The constant −KW-KW affects only an overall time-dependent phase.

    The figure compares this prediction with evolution in the explicitly projected space. Its exact destructive node requires equal hopping paths; the Wilson sign remains meaningful when their amplitudes differ.

    A vison shifts the four ring energies and suppresses arrival at the opposite site through destructive interference.

    An exactly constrained four-site charge interferometer. Left: kinetic energies in the two flux sectors, with degeneracies labeled; the constant −KW-KW is omitted. Right: opposite-site arrival probability from an initially localized charge, with hopping setting the time unit. Curves are analytic; markers come from matrix evolution in the projected Hilbert space. This finite ring measures charge–vison interference and is not a thermodynamic phase diagram.

    Across 71 times, matrix evolution agrees with the probabilities to below 9×10−16{9\times10^{-16}}. As a separate integration check, fourth-order Runge–Kutta evolution to s=1.1s=1.1 has state-vector errors 2.35×10−4{2.35\times10^{-4}}, 1.47×10−5{1.47\times10^{-5}}, 9.19×10−7{9.19\times10^{-7}} and 5.74×10−8{5.74\times10^{-8}} at 8, 16, 32 and 64 steps. The factor of about sixteen under step halving checks the time evolution, not a larger-system phase claim.

    Fluctuating flux and paired partons

    Turning on hh preserves Gauss's law but mixes the bare Wilson sectors. In the same four-site example the ground-state expectation ⟨W⟩\langle W\rangle is 11, 0.9926130.992613, 0.8911480.891148 and 0.5508210.550821 at h=0h=0, 0.050.05, 0.20.2 and 0.50.5, respectively. A noninteger expectation is a superposition of flux sectors, not a fractional eigenvalue of WW and not by itself evidence of confinement.

    In an infinite two-dimensional system, gapped visons and a stable topological ground-state sector make the deconfined phase meaningful. Its microscopic local loop expectation need not remain exactly one. At nonzero temperature, thermally excited visons introduce another scale; the zero-temperature topological-order conclusion should not be replaced by a claim of an indefinitely stable two-dimensional thermal memory.

    How can a parton ansatz lead to this structure? In an effective U(1)U(1) gauge description, a spinon pair field has gauge charge two: Φ↦e2iαΦ{\Phi\mapsto e^{2i\alpha}\Phi} when f↦eiαff\mapsto e^{i\alpha}f. In a gauge-fixed paired saddle, the transformations preserving its phase are α=0,π\alpha=0,\pi. This motivates a residual Z2\mathbb Z_2 gauge description. The exact local redundancy has not spontaneously broken: a gauge-variant expectation is not a physical order parameter. One must still check the ansatz's full IGG, the gap and dynamics of gauge flux, and the physical symmetry action. Pairing by itself does not prove deconfinement or rule out confinement and conventional order.

    Summary

    Gauss's law forces charge creation and transport to include gauge strings. At a controlled two-dimensional point the constrained matter model maps exactly to the toric code: electric and vison pairs have separation-independent energies, and one crossing gives the mutual sign −1-1. The projected ring turns that sign into a shifted spectrum and an explicitly calculated interference signal. The bare parton label, the exact finite-system diagnostic and the thermodynamic phase remain distinct statements.

    The full matrices, projection, time-step checks and figure generator are in examples/condensed-matter/spin-liquids/partons-z2/.

    Exercises

    1. A vison costs more than its bare magnetic energy

    Keep the mobile charge equilibrated within a fixed Wilson sector of the four-site ring. Calculate the free-energy difference F−−F+F_--F_+ at temperature TT, including the magnetic term. Find its low- and high-temperature limits for positive tt.

    Solution

    Summing the four physical states in each sector gives

    Z+=eK/T[2+2cosh⁡(2t/T)],Z−=4e−K/Tcosh⁡(2t/T).Z_+=e^{K/T}[2+2\cosh(2t/T)],\qquad Z_-=4e^{-K/T}\cosh(\sqrt2t/T).

    Hence

    F−−F+=2K−Tlog⁡ ⁣[4cosh⁡(2t/T)2+2cosh⁡(2t/T)].F_--F_+=2K-T\log\!\left[\frac{4\cosh(\sqrt2t/T)}{2+2\cosh(2t/T)}\right].

    At low temperature the no-vison kinetic ground energy is −2t-2t and the vison kinetic ground energy is −2t-\sqrt2t, with multiplicities one and two. Thus

    F−−F+=2K+(2−2)t−Tlog⁡2+o(T).F_--F_+=2K+(2-\sqrt2)t-T\log2+o(T).

    At high temperature, expansion of the two traces gives

    F−−F+=2K+t46T3+O(t6/T5).F_--F_+=2K+\frac{t^4}{6T^3}+O(t^6/T^5).

    The bare flux cost is 2K2K; the probe's kinetic response adds a separate contribution. In particular, the low-temperature difference is not a pure vison gap of the empty two-dimensional system.

    2. Does the interference zero survive unequal paths?

    In the W=−1{W=-1} ring replace the hopping on link zero by t+δtt+\delta t, leaving the other three equal to tt. Compute the leading short-time arrival probability at site two. Does its nonzero value remove the charge–vison statistical phase?

    Solution

    There are two two-hop paths. In the gauge with the negative link between three and zero,

    ⟨2∣Hkin2∣0⟩=t(t+δt)−t2=t δt.\langle2|H_{\mathrm{kin}}^2|0\rangle=t(t+\delta t)-t^2=t\,\delta t.

    The zeroth- and first-order transition amplitudes vanish, so expansion of the evolution operator gives

    ⟨2∣e−iHkins∣0⟩=−12t δt s2+O(s4),P2(s)=14t2(δt)2s4+O(s6).\langle2|e^{-iH_{\mathrm{kin}}s}|0\rangle=-\frac12t\,\delta t\,s^2+O(s^4), \qquad P_2(s)=\frac14t^2(\delta t)^2s^4+O(s^6).

    Odd powers in this matrix element vanish because the hopping graph is bipartite. The two amplitudes still have the relative Wilson sign −1-1, but unequal magnitudes no longer cancel. Exact extinction at a detector is a property of the symmetric interferometer; mutual charge–vison statistics does not require that tuning.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.