- Home
- Library
- Condensed-Matter Field Theory
- Elasticity, Phonons, and Electrons in a Crystal
- Measuring Phonons with the Dynamic Structure Factor
Measuring Phonons with the Dynamic Structure Factor
A transverse peak disappears from a neutron spectrum. Rotating the momentum transfer into a neighboring Brillouin zone brings it back at the same energy. Which part of the experiment changed? The crystal momentum fixes the mode, while the full momentum transferred by the neutron selects the component of its displacement that the nucleus can reveal.
Preparation. Use the in-plane normal coordinates of the finite square monatomic sheet. The spectroscopy article defines the unsymmetrized density spectrum per volume. Here the number of primitive cells replaces the volume and the density carries the coherent nuclear scattering length . We use , the center of mass fixed, and an inversion-symmetric harmonic crystal.
Derive the one-phonon lines
For a spin-independent nuclear probe the amplitude is
The connected correlation removes the mean elastic amplitude. Define the frequency so is energy gained by the sample,
To first order in displacement and for at an allowed nonzero reduced wavevector, the lattice sum picks out just one Fourier coordinate,
Here for a reciprocal vector . The factor cancels the per-cell normalization in the intensity. The time dependence of contains a lowering operator at and a raising operator at . Their thermal contractions are and , respectively, with .
Restoring all same-site Gaussian contractions in the density exponent multiplies the intensity by , where . The term linear in the remaining two-time covariance gives the coherent one-phonon lines
Setting is consistent at leading order in the small displacement expansion. Keeping it gives the one-phonon sector of the harmonic Gaussian result, alongside higher-phonon sectors. Use a finite sheet for the absolute Debye–Waller factor. In the ideal unpinned two-dimensional thermodynamic limit, thermal long-wavelength displacements make its exponent size dependent. The formulas here concern resolved in-plane lines of a finite specimen.
The integrated peak area remains meaningful after convolution with a normalized resolution function if the full line is collected and neighboring lines can be separated. Measured counts also include the outgoing-to-incoming neutron wave-number ratio, acceptance, backgrounds and resolution. A fit to peak height alone needs a model of the line shape. Berk, §3.5.1, Eqs. (105)–(110)
Change the reciprocal vector and predict the peak areas
Choose , axial , diagonal and in a periodic sample with a multiple of six cells along . The exact frequencies are , . Compare with at . The table gives the positive-frequency areas divided by , separately at each momentum transfer.
| Momentum transfer | Transverse | Longitudinal |
|---|---|---|
The first geometry gives , so the transverse mode contributes no one-phonon nuclear amplitude. In the second geometry the same mode has . Its creation area is because and . The longitudinal areas instead change by . Dividing away the known Debye–Waller factor is essential when comparing different zones.
At a fixed the annihilation-to-creation area ratio for either branch is . In the transverse channel at the negative-frequency reduced area is therefore . Reversing the energy transfer at fixed geometry tests the temperature factor. Changing geometry at fixed energy tests the polarization.
A moment that checks the normalization
Taking a signed frequency moment cancels the Bose factors. Completeness of the two in-plane polarizations gives, for this in-plane ,
For unconstrained nuclei the full density has first moment for a kinetic energy quadratic in nuclear momenta and a position-dependent potential. In the bulk the complementary weight resides in higher-phonon sectors. Removing center-of-mass motion first in a finite sample also removes the sample recoil. At finite resolution a missing branch should first be tested by changing while holding fixed. To change the pole itself, change the restoring force, as in the bond response of the half-filled chain.
Exercises
1. Infer a temperature. At a geometry where a branch is visible its reduced integrated areas are and for energy transfer meV. What is ?
Solution
Detailed balance gives meV. The unknown common nuclear intensity factor cancels. The two measured windows must be corrected for any different kinematic or efficiency factors and must cover the same branch.
2. Can higher efficiency recover an extinct mode? A weak line at appears at nominal . Give a test for finite angular acceptance.
Solution
For held along , an error in the transverse projection of the scattering vector enters the one-phonon amplitude linearly, hence its area quadratically. More generally the distribution of accepted also changes the eigenvector. Average over the calibrated acceptance, then narrow the acceptance and compare with the finite signal at . A line that persists at exactly zero projection requires another contribution, such as unresolved modes or multiphonon intensity.
References
- N. F. Berk, “Outline of Neutron Scattering Formalism,” §3.5.1, Eqs. (105)–(110). Eq. (108) includes continuum momentum delta functions. Here discrete crystal momenta and per-cell normalization replace them with the reciprocal-vector selection rule. Journal of Research of NIST
- The Phonopy developers document the coherent creation amplitude, with basis phases, site masses and scattering lengths needed for a multicomponent experimental sample. Dynamic structure factor, Theory
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.