Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Spectroscopy and Response in Quantum Matter

    A bright band in a photoemission image and a peak in a density-scattering spectrum need not represent the same excitation. Photoemission removes one particle; a density perturbation moves particles between states without changing their total number. Even for a free gas, the first measurement follows a single-particle dispersion while the second sees a continuum of particle–hole energies.

    We calculate both signals for the same gas, including a specified instrumental resolution. This makes several inference problems concrete: an observed width need not be a lifetime, intensity above the chemical potential need not mean thermal occupation, and a density spectrum is not a momentum-resolved single-particle spectral function.

    Preparation: Single-Particle Green Functions and Spectral Functions defines fermionic spectral weight. Density Response and Screening derives the free density continuum and its sum rules.

    Use the three-dimensional balanced spin-1/21/2 gas with ℏ=kB=1\hbar=k_B=1 and T=0T=0:

    εk=k22m,μ=EF=kF22m,n=kF33π2.\varepsilon_{\mathbf k}=\frac{k^2}{2m},\qquad \mu=E_F=\frac{k_F^2}{2m},\qquad n=\frac{k_F^3}{3\pi^2}.

    The computed probe examples have no interactions. The Coulomb RPA extension in the screening article is a separate model. Our photoemission image is an idealized cut through this continuum gas, not a quantitative model of a particular solid or its surface.

    One-particle removal and the frequency origin

    For one spin component, evolve the annihilation operator with K=H−μNK=H-\mu N. The retarded anticommutator propagator and spectral function are

    GR(k,t)=−iθ(t)⟨{ak(t),ak†(0)}⟩,A(k,ω)=−2Im⁡GR(k,ω).G_R(\mathbf k,t)=-i\theta(t)\langle\{a_{\mathbf k}(t),a^\dagger_{\mathbf k}(0)\}\rangle,\qquad A(\mathbf k,\omega)=-2\operatorname{Im}G_R(\mathbf k,\omega).

    With the time transform eiωte^{i\omega t}, the free result is

    ξk=εk−μ,GR(k,ω)=1ω−ξk+i0,A(k,ω)=2πδ(ω−ξk).\xi_{\mathbf k}=\varepsilon_{\mathbf k}-\mu,\qquad G_R(\mathbf k,\omega)=\frac{1}{\omega-\xi_{\mathbf k}+i0},\qquad A(\mathbf k,\omega)=2\pi\delta(\omega-\xi_{\mathbf k}).

    The equal-time anticommutator fixes ∫dω A/(2π)=1\int d\omega\,A/(2\pi)=1. Thermal equilibrium supplies the occupied weight,

    ⟨ak†(0)ak(t)⟩=∫dω2π e−iωtfF(ω)A(k,ω),fF(ω)=1eβω+1.\langle a^\dagger_{\mathbf k}(0)a_{\mathbf k}(t)\rangle =\int\frac{d\omega}{2\pi}\,e^{-i\omega t}f_F(\omega)A(\mathbf k,\omega),\qquad f_F(\omega)=\frac{1}{e^{\beta\omega}+1}.

    At zero temperature, fF(ω)=θ(−ω)f_F(\omega)=\theta(-\omega). The removal signal therefore has support on the occupied part of the parabola. The frequency is measured relative to μ\mu because the operator changes particle number. Under evolution with HH, the free pole would instead lie at εk\varepsilon_{\mathbf k}.

    To see where the measured weight comes from, model the weak probe by an operator that transfers a particle to an initially empty outgoing state. Its transition matrix element contains the dipole factor MM and a many-body removal matrix element. Summing over the unobserved final states gives the occupied spectral weight. In a sudden-approximation description with a specified outgoing channel, the ideal signal is thus

    Iideal(k,ω)=∣M(k,ω)∣2 fF(ω)A(k,ω)2π.I_{\rm ideal}(\mathbf k,\omega) =|M(\mathbf k,\omega)|^2\,f_F(\omega)\frac{A(\mathbf k,\omega)}{2\pi}.

    An overall flux and detector efficiency have been absorbed into the intensity unit. A vanishing matrix element can hide spectral weight; it does not prove that the state is absent. Final-state scattering, surface sensitivity, background counts, and the relation between measured emission angle and bulk momentum require additional modeling in a real material.

    Damascelli, arXiv:cond-mat/0307085v1, §§IV–V, Eqs. (20), (22), (25)–(27) (PDF) develops the occupied-weight and resolution formulas. Its spectral function is normalized to unit frequency integral, so it equals A/(2π)A/(2\pi) in our convention.

    A calculated photoemission image

    Choose a line through momentum space, ky=kz=0k_y=k_z=0, and write k=kxk=k_x. We set M=1M=1 along this line and assume that the transverse momenta are selected exactly. The following convolution is therefore over the one-dimensional cut measure dk′dk', not over d3k′d^3k' or a three-dimensional density of states.

    For either momentum or energy resolution, define a normalized Gaussian

    Rσ(x)=e−x2/(2σ2)2πσ,∫−∞∞dx Rσ(x)=1.R_\sigma(x)=\frac{e^{-x^2/(2\sigma^2)}}{\sqrt{2\pi}\sigma},\qquad \int_{-\infty}^{\infty}dx\,R_\sigma(x)=1.

    Convolve the physical occupied intensity:

    Iobs(k,ω)=∫dk′ dω′ Rσk(k−k′)RσE(ω−ω′)Iideal(k′,ω′).I_{\rm obs}(k,\omega) =\int dk'\,d\omega'\, R_{\sigma_k}(k-k')R_{\sigma_E}(\omega-\omega') I_{\rm ideal}(k',\omega').

    For the zero-temperature free gas, the delta function does the energy integral:

    Iobs(k,ω)=∫−kFkFdk′ Rσk(k−k′)RσE ⁣(ω−k′2−kF22m).\boxed{I_{\rm obs}(k,\omega) =\int_{-k_F}^{k_F}dk'\, R_{\sigma_k}(k-k')R_{\sigma_E}\!\left(\omega-\frac{k'^2-k_F^2}{2m}\right).}

    Multiplying a broadened AA by a sharp Fermi function afterward would be a different operation and would incorrectly erase measured leakage across ω=0\omega=0. The detector broadens already emitted particles.

    The numerical example uses m=kF=1m=k_F=1, so EF=1/2E_F=1/2, with

    σk=0.06kF,σE=0.05EF.\sigma_k=0.06k_F,\qquad \sigma_E=0.05E_F.

    All momentum and energy integrals in the normalization statements extend over the complete measured axes. Gaussian resolution preserves the total cut weight and its energy first moment:

    ∫dk dω Iobs=2kF,∫dk dω ωIobs=∫−kFkFdk′ ξk′=−2kF33m.\int dk\,d\omega\,I_{\rm obs}=2k_F,\qquad \int dk\,d\omega\,\omega I_{\rm obs} =\int_{-k_F}^{k_F}dk'\,\xi_{k'}=-\frac{2k_F^3}{3m}.

    It does not preserve the intensity at each momentum. In the calculation, 1.01364%1.01364\% of the total signal is recorded at positive measured energy, and 2.39365%2.39365\% at measured ∣k∣>kF|k|>k_F. Both effects arise in an exactly zero-temperature, infinite-lifetime gas.

    At the cut k=0.6kFk=0.6k_F, the normalized energy distribution has

    ⟨ω⟩=−0.3182000000,Var⁡(ω)=0.0019274800(m=kF=1).\langle\omega\rangle=-0.3182000000,\qquad \operatorname{Var}(\omega)=0.0019274800 \quad (m=k_F=1).

    Its mean differs from ξk=−0.32\xi_k=-0.32, and its width exceeds σE\sigma_E. Momentum resolution mixes different points on the curved dispersion. Exercise 1 derives both effects without fitting a linewidth.

    Density scattering and the structure factor

    A weak density probe couples to nqn_{\mathbf q}, which preserves total particle number. Its frequency is an energy transfer and is independent of whether the density operator is evolved with HH or KK. For a homogeneous system, define the connected, unsymmetrized structure factor per volume by

    S(q,ω)=12πV∫dt eiωt⟨δnq(t)δn−q(0)⟩.S(q,\omega)=\frac{1}{2\pi\mathcal V}\int dt\,e^{i\omega t} \langle\delta n_{\mathbf q}(t)\delta n_{-\mathbf q}(0)\rangle.

    This definition includes both spins and one explicit 1/(2π)1/(2\pi). Its frequency integral is the equal-time connected density variance per volume. The Lehmann representation is

    S(q,ω)=1V∑a,bpa∣⟨b∣δn−q∣a⟩∣2δ(ω−Eb+Ea).S(q,\omega)=\frac{1}{\mathcal V}\sum_{a,b}p_a |\langle b|\delta n_{-\mathbf q}|a\rangle|^2 \delta(\omega-E_b+E_a).

    For positive ω\omega, the probe can supply energy to the system. Interchanging aa and bb gives detailed balance in an equilibrium, inversion-symmetric gas. The commutator spectral function and fluctuation–dissipation relation are

    S(q,−ω)=e−βωS(q,ω),ρnn(q,ω)=−2Im⁡χ0(q,ω),S(q,-\omega)=e^{-\beta\omega}S(q,\omega),\qquad \rho_{nn}(q,\omega)=-2\operatorname{Im}\chi_0(q,\omega), S(q,ω)=−Im⁡χ0(q,ω)π(1−e−βω).\boxed{S(q,\omega)= \frac{-\operatorname{Im}\chi_0(q,\omega)} {\pi(1-e^{-\beta\omega})}.}

    The retarded function here has the site's −iθ-i\theta commutator sign. Its negative imaginary part at positive frequency makes SS positive. It is essential to distinguish this unsymmetrized spectrum from the symmetrized noise spectrum; their thermal factors differ.

    At T=0T=0 and ω>0\omega>0, the phase-space integral from the screening article gives

    S0(q,ω)=m4π2q[kF2−pmin⁡2]+,pmin⁡2=max⁡{(mωq−q2)2, kF2−2mω, 0}.S_0(q,\omega)=\frac{m}{4\pi^2q}[k_F^2-p_{\min}^2]_+,\qquad p_{\min}^2=\max\left\{\left(\frac{m\omega}{q}-\frac q2\right)^2,\ k_F^2-2m\omega,\ 0\right\}.

    Here [y]+=max⁡(y,0)[y]_+=\max(y,0), and S0S_0 vanishes at negative frequency. Its continuum extends from ω−=max⁡(0,q2/(2m)−qvF)\omega_-=\max(0,q^2/(2m)-qv_F) to ω+=q2/(2m)+qvF\omega_+=q^2/(2m)+qv_F. A density probe moves an occupied particle to an empty state, so many initial momenta contribute at each qq. That is why this signal is broad even though every single-particle excitation has zero intrinsic width.

    Two useful normalizations are

    1n∫dω S0(q,ω)={3q4kF−q316kF3,q≤2kF,1,q≥2kF,1n∫dω ωS0(q,ω)=q22m.\frac{1}{n}\int d\omega\,S_0(q,\omega) = \begin{cases} \dfrac{3q}{4k_F}-\dfrac{q^3}{16k_F^3},&q\leq2k_F,\\[4pt] 1,&q\geq2k_F, \end{cases} \qquad \frac{1}{n}\int d\omega\,\omega S_0(q,\omega)=\frac{q^2}{2m}.

    The first measures the fraction of the Fermi sphere that can be scattered into empty states. The second is the density ff-sum rule. They test different aspects of the signal.

    From a moving potential to a measured Bragg rate

    Apply a weak traveling potential

    H′(t)=U0∫d3x cos⁡(q⋅x−ωt)n(x)=U02(e−iωtn−q+eiωtnq).H'(t)=U_0\int d^3x\,\cos(\mathbf q\cdot\mathbf x-\omega t)n(\mathbf x) =\frac{U_0}{2}\left(e^{-i\omega t}n_{-\mathbf q}+e^{i\omega t}n_{\mathbf q}\right).

    The first term supplies energy ω\omega and momentum q\mathbf q. Fermi's golden rule gives the absorption-event rate per volume,

    ΓabsV=πU022S(q,ω).\frac{\Gamma_{\rm abs}}{\mathcal V}=\frac{\pi U_0^2}{2}S(q,\omega).

    The opposite process contributes negative momentum. The net momentum-transfer rate is therefore

    1VdPdt=πU022 q [S(q,ω)−S(q,−ω)].\frac{1}{\mathcal V}\frac{d\mathbf P}{dt} =\frac{\pi U_0^2}{2}\,\mathbf q \,[S(q,\omega)-S(q,-\omega)].

    At zero temperature and positive drive frequency, the second spectrum vanishes. At finite temperature, measuring net momentum is not identical to measuring the positive-frequency event rate. This distinction follows from the operator coupling, independently of whether the gas is Bose or Fermi.

    The traveling-potential and golden-rule construction appears in Stamper-Kurn et al., arXiv:cond-mat/9906035v2, p. 1, paragraphs beginning “In optical Bragg spectroscopy” and “The response” (PDF). Their structure factor is per particle, namely S/nS/n here, and their two-photon Rabi frequency is U0/2U_0/2 with ℏ=1\hbar=1. Their experiment concerns a Bose condensate; the Fermi-gas continuum calculated here is a different state.

    Our synthetic density measurement reports the per-particle spectrum with Gaussian energy resolution:

    Sobs(q,ω)=1n∫dω′ RσB(ω−ω′)S0(q,ω′),σB=0.06EF.\mathcal S_{\rm obs}(q,\omega) =\frac{1}{n}\int d\omega'\,R_{\sigma_B}(\omega-\omega')S_0(q,\omega'), \qquad \sigma_B=0.06E_F.

    We assume a sufficiently long, weak pulse for the golden-rule spectrum and specify the Gaussian as the instrument response. A finite pulse would supply its own Fourier window. The displayed Gaussian does not represent a collision rate or a many-body decay width.

    Calculated photoemission intensity along a momentum cut follows the occupied free-particle parabola with Gaussian smearing. Two density spectra show broad particle–hole continua, with solid curves for instrument resolution and dotted curves for the ideal spectra.

    Two probes of the same zero-temperature free gas. The left panel is a one-spin, one-dimensional momentum cut with unit matrix element. The right panel includes both spins and is normalized per particle. Instrumental widths are stated in the text; neither panel introduces an intrinsic lifetime.

    For the numerical units m=kF=1m=k_F=1, direct integration gives:

    q/kFq/k_FIdeal interval [ω−,ω+][\omega_-,\omega_+]∫dω Sobs\int d\omega\,\mathcal S_{\rm obs}∫dω ωSobs\int d\omega\,\omega\mathcal S_{\rm obs}
    0.6[0, 0.78][0,\ 0.78]0.43650000.1800000
    1.5[0, 2.625][0,\ 2.625]0.91406251.1250000
    2.6[0.78, 5.98][0.78,\ 5.98]1.00000003.3800000

    Normalized, centered resolution preserves both moments when the measured energy integral includes its negative tail. At q=0.6kFq=0.6k_F, the integrated negative-energy signal is 0.00056250.0005625 per particle. This is instrumental leakage; the underlying zero-temperature gas cannot emit positive energy. Discarding the negative measured tail would spoil the moment tests.

    The reproducible calculation in examples/condensed-matter/many-body-fields/response-probes/ checks the convolution against separate adaptive integration. At q=2.6kFq=2.6k_F, 128, 256 and 512 quadrature nodes give maximum sampled pointwise errors of 7.12×10−37.12\times10^{-3}, 1.46×10−81.46\times10^{-8} and 2.61×10−152.61\times10^{-15}. Integrated moments can already look accurate while the local line shape is unresolved. Both checks are needed.

    What tunneling and neutrons couple to

    Tunneling generally measures a local electron-removal/addition spectrum rather than a density commutator. For a weak local transfer amplitude between a tip and the sample, the forward and reverse golden-rule rates give, up to a positive apparatus factor,

    I(V)∝∫dω νtip(ω−eV)νsample(r,ω)[fF(ω−eV)−fF(ω)].I(V)\propto\int d\omega\,\nu_{\rm tip}(\omega-eV)\nu_{\rm sample}(\mathbf r,\omega) [f_F(\omega-eV)-f_F(\omega)].

    Here e>0e>0, the tip chemical potential is higher by eVeV, and both densities of states include the relevant local tunneling matrix elements. With a constant tip density of states and an energy-independent transfer amplitude, zero-temperature differentiation gives dI/dV∝νsample(r,eV)dI/dV\propto\nu_{\rm sample}(\mathbf r,eV). A structured tip or nonlocal tunneling amplitude invalidates that simple identification.

    For the free gas, the local density of states per spin is the momentum integral of A/(2π)A/(2\pi):

    νsample(ω)=∫d3k(2π)3A(k,ω)2π=m2m(ω+μ)2π2 θ(ω+μ).\nu_{\rm sample}(\omega)=\int\frac{d^3k}{(2\pi)^3}\frac{A(\mathbf k,\omega)}{2\pi} =\frac{m\sqrt{2m(\omega+\mu)}}{2\pi^2}\,\theta(\omega+\mu).

    Thus even this elementary tunneling spectrum has a different shape from a cut through the photoemission parabola. Momentum integration has changed the question.

    Magnetic neutron scattering instead couples to magnetization. Its cross section contains the spin structure-factor tensor contracted with the projector transverse to momentum transfer,

    ∑α,β(δαβ−Q^αQ^β) Sspinαβ(Q,ω),\sum_{\alpha,\beta} (\delta_{\alpha\beta}-\widehat Q_\alpha\widehat Q_\beta)\, S_{\rm spin}^{\alpha\beta}(\mathbf Q,\omega),

    as well as magnetic form factors and neutron kinematics. Nuclear scattering can probe atomic positions and phonons through a different coupling. Neither measurement is generically the electron-density SS calculated above. Before interpreting any peak as a particle, spin mode, or collective charge mode, identify the operator to which the apparatus couples.

    A coherent nuclear probe of a monatomic crystal couples to the displacement projected along the full scattering vector. Keeping the reduced momentum fixed while changing reciprocal zones can extinguish a transverse phonon and recover it at the same energy. This gives an operator-specific test alongside the magnetic projector above.

    For the magnetic cross section and its per-unit-cell spin normalization, see Xu, Xu, and Tranquada, arXiv:1305.5521v1, Eqs. (3)–(4) (PDF). Their negative time-transform phase accompanies the opposite assignment of the time argument. Reversing the integration variable and using time and spatial translation invariance gives our positive-phase convention without interchanging the spin indices.

    Summary

    The free gas has a delta-function one-particle spectral function and a broad density continuum. Photoemission selects occupied single-particle weight and multiplies it by a matrix element; Bragg scattering measures a density transition spectrum, or its absorption–emission difference when momentum transfer is recorded. Tunneling integrates a local single-particle spectrum, while magnetic neutron scattering selects spin correlations.

    Our two explicit signals separate those operator choices from instrumental resolution. Their sum rules survive normalized convolution over complete measured axes, but apparent widths and leakage can change strongly. A response model, its occupation factors, and its measurement convolution must all be specified before an observed line shape can be assigned a microscopic lifetime.

    Exercises

    1. A resolution width without a decay rate

    Consider a cut well inside the occupied interval, so that the momentum Gaussian can be extended over the real line with negligible error. Let k′=k+δkk'=k+\delta k, with δk\delta k Gaussian of variance σk2\sigma_k^2, and add an independent Gaussian energy error of variance σE2\sigma_E^2. Derive the mean and variance of the measured energy. Evaluate them at the numerical cut used above.

    Solution

    The measured energy is

    ω=ξk+kmδk+δk22m+δE.\omega=\xi_k+\frac{k}{m}\delta k+\frac{\delta k^2}{2m}+\delta E.

    Use ⟨δk⟩=⟨δk3⟩=0\langle\delta k\rangle=\langle\delta k^3\rangle=0, ⟨δk2⟩=σk2\langle\delta k^2\rangle=\sigma_k^2, and ⟨δk4⟩=3σk4\langle\delta k^4\rangle=3\sigma_k^4. The mean and variance are

    ⟨ω⟩=ξk+σk22m,Var⁡(ω)=σE2+k2σk2m2+σk42m2.\langle\omega\rangle=\xi_k+\frac{\sigma_k^2}{2m},\qquad \operatorname{Var}(\omega)=\sigma_E^2+\frac{k^2\sigma_k^2}{m^2}+\frac{\sigma_k^4}{2m^2}.

    The mixed covariance of the linear and quadratic momentum terms vanishes by symmetry. At m=kF=1m=k_F=1, k=0.6k=0.6, σk=0.06\sigma_k=0.06, and σE=0.025\sigma_E=0.025, these formulas give −0.3182-0.3182 and 0.001927480.00192748. The exact occupied-interval convolution agrees to about 10−1210^{-12} in the variance because this cut lies far from its endpoints.

    The width is entirely instrumental: the spectral function before convolution is a delta function. Near kFk_F, the occupied-interval truncation matters and these untruncated Gaussian formulas must be replaced by the full integral.

    2. What a thermal Bragg measurement determines

    At finite temperature, suppose a homogeneous inversion-symmetric system has a positive-frequency structure factor S(q,ω)S(q,\omega). Express its negative-frequency spectrum and net Bragg momentum-transfer rate in terms of S(q,ω)S(q,\omega). Does Gaussian broadening preserve the pointwise detailed-balance ratio?

    Solution

    In the Lehmann sum, exchange the initial and final states. On the delta-function support their thermal probabilities satisfy pb=e−βωpap_b=e^{-\beta\omega}p_a. Inversion symmetry removes the reversal of q\mathbf q, giving

    S(q,−ω)=e−βωS(q,ω),1VdPdt=πU022 q (1−e−βω)S(q,ω).S(q,-\omega)=e^{-\beta\omega}S(q,\omega),\qquad \frac{1}{\mathcal V}\frac{d\mathbf P}{dt} =\frac{\pi U_0^2}{2}\,\mathbf q\,(1-e^{-\beta\omega})S(q,\omega).

    The measured net transfer vanishes in the zero-frequency limit for a regular SS; it is the difference of forward and reverse rates. Dividing by the thermal factor is justified only with the stated equilibrium assumptions and a controlled treatment of the small-frequency limit.

    For an even Gaussian kernel, the broadened negative spectrum satisfies

    Sobs(−ω)=∫dω′ RσB(ω−ω′) e−βω′S(ω′).S_{\rm obs}(-\omega)=\int d\omega'\, R_{\sigma_B}(\omega-\omega')\,e^{-\beta\omega'}S(\omega').

    The factor inside the integral is e−βω′e^{-\beta\omega'}, not e−βωe^{-\beta\omega}. It generally cannot be pulled out, so pointwise detailed balance is not preserved by convolution. This is consistent with the negative measured tail of the zero-temperature example. Compare a resolution-convolved theoretical spectrum with the data; do not infer a temperature from an uncorrected ratio of adjacent broadened tails.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.