- Home
- Library
- Lattice and Hamiltonian Field Theory
- Thermodynamics on the Lattice
- What Can Lattice Current Correlators Tell Us about Transport?
What Can Lattice Current Correlators Tell Us about Transport?
Two thermal media can have quite different conductivities and very similar Euclidean current correlators. The reason is that a Euclidean measurement averages the spectrum over frequency, while the direct-current conductivity depends on its slope at zero frequency. Resolving that slope requires more than a visually smooth correlator.
We construct two positive response spectra whose regular conductivities differ by a factor of four. Their Euclidean means are weakly distinguishable at a declared correlated precision. We also calculate a broad spectral average that those same data constrain directly, with an exact prospective variance. No random data are generated and no spectrum is fitted in this example.
Preparation: Thermal spectral representations and Kubo formulas and contact terms. The distinction between spatial screening and real-time response is developed in Thermal Screening Correlators.
Normalize the current before taking a transport limit
Consider one Hermitian physical spatial current component in dimensions. Let , with its charge normalization included, and subtract its equilibrium mean. At zero spatial momentum define
The site's convention is . For this diagonal physical channel, at positive frequency and . These statements are about a physical current in a positive Hilbert space; they do not automatically hold for arbitrary gauge-fixed fields or individual off-diagonal matrix entries.
A spatial vector potential changes both the state and the current operator. With the source and Fourier signs used here, the complete response can be written
where denotes the appropriately renormalized local current contact in this channel. At nonzero real frequency its regular dissipative part is
There is no sum over three spatial directions in our definition, hence no additional factor of three or six. A lattice local current must be normalized and improved as appropriate before its correlator can be used here; a multiplicative factor on the current gives on the two-point function. An exactly conserved discretized current has its own source-derived normalization and contact terms.
The direct-current limit takes the bulk, thermodynamic response limit before . A finite isolated box instead has discrete transitions. A possible ballistic term proportional to in is not fixed by the nonzero-frequency expression alone: the contact divided by matters. Our comparison explicitly assumes no ballistic delta function and a well-defined regular limit. It is a comparison of specified response spectra, not a derivation of relaxation from a microscopic Hamiltonian.
What the Euclidean correlator averages
At first keep a finite regulator. In energy eigenstates, the connected Wightman function has nonnegative transition weights. Detailed balance relates downward and upward transitions by . The commutator multiplies an upward weight by . Combining positive and negative nonzero transitions gives, for ,
Here denotes the Euclidean continuation of the physical current with its continuation factors fixed. The static term is a possible zero-energy Wightman weight, including transitions within degenerate energy blocks. It survives centering but cancels out of the commutator. It is distinct from the local response contact .
The two models below assume . Separated Euclidean times avoid local contact distributions at coincident points, but they do not prove that a static Wightman complement or a ballistic conductivity term is absent. The ultraviolet spectrum used below also requires a subtracted dispersion relation and local counterterms for ; an unsubtracted static integral over the full spectrum would diverge.
Meyer, §5.1, Eq. (269), PDF gives the separated-point kernel. His spectral function equals our and his retarded sign is opposite, so the displayed normalization has been translated. The complete thermal trace, current convention and contacts determine which correlator that relation describes.
For small frequency,
Thus low-frequency spectral weight contributes almost a constant in Euclidean time. Its distribution inside a narrow frequency interval affects the correlator only at higher order. This explains the loss of sensitivity, but a quantitative statement still needs the measurement covariance.
Two positive spectra with different slopes
For , prescribe
Extend oddly to negative frequency. The half Gaussian obeys . Both pieces are positive at . The dimensions are , , and in mass units, so and .
Choose , and compare with . The shared ultraviolet part behaves as at large frequency and does not contribute to the zero-frequency slope. The regular conductivities are
At they are and . These slopes belong to the two specified spectral models.
The comparison holds fixed the low-piece inverse-frequency moment:
This equality is imposed by our choice of . It is not a sum rule established for a physical current. For the convergent low piece alone, dispersion gives , so a contact would cancel its static vector-potential response. The shared ultraviolet piece requires its own renormalized subtraction; that low-piece identity does not define the full contact.
Evaluate the continuum kernel at nine distinct times on the reflected half interval:
These are possible lattice sampling locations, but the example does not compute a finite-spacing current or a corrected lattice kernel. The resulting Euclidean curves differ by at most relative to the narrower model. Their arithmetic means are and . The factor-four change in transport therefore produces a much smaller change in these Euclidean means.
Distinguishability depends on correlations and precision
Declare a prospective Gaussian distribution for one estimated correlator vector, with known covariance . This is a covariance of the mean, not the covariance of an individual simulation measurement. Set
The times are distinct but the proposed errors are correlated. The same covariance is used under both hypotheses. Let and be their calculated Euclidean means, and . Their squared Mahalanobis separation is
This compares the whole correlated vector. Treating nine small pointwise discrepancies as independent would be a different statistical experiment.
For these two fully specified Gaussian hypotheses and equal prior probabilities, the optimal classifier uses
Under model 1 its mean is and variance ; under model 2 the mean reverses sign. The common error probability is therefore
where is the standard normal cumulative distribution. This is a prospective discrimination calculation, not a goodness-of-fit result for an observed dataset. No draw or fit was performed.
Reducing every standard deviation by a factor of ten, while holding the means and correlation matrix fixed, gives and . The example thus shows weak discrimination at the stated precision, not exact nonuniqueness. Allowing additional unknown spectral structure would be a broader inverse problem and could change the conclusion about attainable transport accuracy.
A spectral average directly determined by the data
A finite set of Euclidean values can determine some broad spectral functionals without determining the pointwise slope. To exhibit one, use fixed coefficients and define . Then
The original kernel diverges at zero frequency. The weight on is instead smooth there. Its integral can be evaluated exactly: expand the kernel in positive exponential images, integrate , and sum the resulting inverse squares. This gives
The positive normalized resolution obeys . Therefore the estimator
has expectation and variance
This is an exact linear relation for the declared kernel and the assumed absence of . The general connection between linear estimators, their resolution and data covariance is discussed by Meyer, §5.3, Eqs. (275)–(281), PDF. Our equal-weight functional is chosen explicitly; it is not a reconstruction algorithm selected from the data.
At the stated times, . The broad mean and its prospective standard deviation are:
| Prospective SD divided by | ||
|---|---|---|
| 0.1 | 1.18557398 | 0.00573658 |
| 0.4 | 1.18114386 | 0.00573658 |
The uncertainty is about half a percent, but is a broad average, not . Its weight samples frequencies of order and higher as well as the narrow peak. It is neither a universal physical sum rule nor evidence that the transport slope has half-percent accuracy. If were unknown, the same estimator would also contain and would require that extra input.
The figure displays the three distinct objects: the low-frequency spectrum, the small Euclidean separation measured in units of the declared marginal errors, and the broad positive resolution. The middle curve is a difference of two theoretical means; its units do not make it a random residual.
Deterministic spectral comparison at and . Top: the low-frequency region of for the two widths. Middle: the Euclidean mean difference divided by each prospective marginal standard deviation; the full correlated comparison gives . Bottom: the unit-normalized resolution on . No sampled data or fitted spectrum is shown.
The nine current-correlator means and their covariance are available for this calculation. Each row of correlators corresponds to one listed peak width, and the times in parameters.tau run across the columns. The file sets : the means are in units of and the covariance in units of . Use the same nine times in both the forward kernel and the error propagation. The resolution calculation in Computational QFT measures the frequency interval providing half the kernel area and the change in the quoted error if correlations are discarded.
Numerical controls and what they establish
The companion evaluates the low Gaussian contribution as an expectation of with a half-normal weight. Gauss–Hermite orders 32 and 64 differ by less than at the nine times. Independent adaptive integration in the standardized Gaussian variable agrees within . The zero-frequency value is implemented explicitly, avoiding .
At , put . The small-width expansion has leading term
The checked terms through use the Gaussian moments . The maximum discrepancy after that term is for and for . The comparison tests the small-width asymptotics.
For the ultraviolet part, positivity and bound the omitted integral above by
The largest bound over the selected times is at and at . The observed cutoff change is below the first bound. Numerical integration also verifies the resolution normalization and reconstructs directly from the spectrum. Reflection symmetry, the shared low inverse-frequency moment and positivity of the declared covariance supply further checks.
These controls test quadrature, factors of , the Kubo normalization and error propagation for the specified model. In a lattice calculation one must also control current renormalization, continuum and volume limits, covariance estimation, contact/static terms and the dependence on spectral assumptions.
Exercises
1. How much precision separates the two models?
Multiply every prospective standard deviation by , leaving the means and correlation coefficients fixed. Derive the equal-prior error probability and the largest that gives an error below for these two simple hypotheses.
Solution
The covariance becomes , so . Thus
Since , the requirement is . The marginal errors must be reduced to about of their original values, assuming all other ingredients of these two hypotheses remain known. This says nothing about unknown contact terms or additional spectral parameters; it is a statement about the declared simple comparison.
2. A time difference rejects the leading narrow-peak moment
At , form for . Find the leading low-Gaussian contribution for small , and write its variance in terms of the two-point covariance. Does this difference directly estimate ?
Solution
The term cancels, as does the common term. The expansion therefore gives
The corresponding weight on is , which vanishes at zero frequency. A static complement cancels as well. For measurements with the midpoint,
The low contribution tends to zero as , whereas the model conductivity grows as . A time difference can expose width-dependent curvature only with sufficient precision and control of the ultraviolet contribution. It is not a direct slope estimator. Taking also requires revisiting the assumed regular transport limit rather than replacing a narrow peak by an ordinary finite function at zero frequency.
Summary
Euclidean data constrain kernel-weighted spectral integrals. A regular transport coefficient depends on a zero-frequency limit with a specified current, contact convention and order of limits. The two positive models demonstrate quantitatively how a factor-four slope change can remain weakly distinguishable at a fixed correlated precision. The same measurements determine a broad normalized average of with an exactly propagated prospective error.
The model, deterministic quadratures and checks are in transport_inverse.py, with selected output transport-results.json, under examples/lattice-hamiltonian/thermal-lattice/. plot_transport.py generates the original figure. The covariance is prospective; there is no simulation history, generated noise or fitted result behind the comparison.
References
- Harvey B. Meyer, Transport Properties of the Quark-Gluon Plasma — A Lattice QCD Perspective, European Physical Journal A 47, 86 (2011), arXiv:1104.3708v2, PDF. §2.3, Eq. (41), and §§5.1–5.3, Eqs. (268)–(281): spectral conventions, Euclidean kernel, inverse-problem limitations and linear resolution methods. His is our , with the opposite retarded sign. The Gaussian spectra, prospective covariance and numerical comparison here are independently specified.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.