    A constant vector potential can be a pure gauge, yet a current-current commutator by itself can predict a nonzero current in response to it. The missing piece is that the measured current also depends on the vector potential. Differentiating that dependence produces the diamagnetic contact term.

    The same issue occurs in mechanics: a stress operator changes when the geometry or strain changes. We derive both responses, test electrical gauge invariance in a confined charged oscillator, and use a canonical dilation to check a mechanical contact independently.

    Preparation: Retarded response and source signs. We use GR=−iθ⟨[ , ]⟩G_R=-i\theta\langle[\ ,\ ]\rangle and the Fourier phase e+iωte^{+i\omega t}.

    Differentiate the Hamiltonian and the measured operator

    For a real source s(t)s(t), expand a Hamiltonian as

    H[s]=H0−sX+s22B+O(s3),X[s]=−∂H[s]∂s=X−sB+O(s2).H[s]=H_0-sX+\frac{s^2}{2}B+O(s^3),\qquad \mathcal X[s]=-\frac{\partial H[s]}{\partial s}=X-sB+O(s^2).

    Here X\mathcal X is the physical generalized force conjugate to ss. Its expectation changes through both the perturbed state and the explicit ss dependence. At linear order,

    δ⟨X(t)⟩=∫dt′ K(t−t′)s(t′),K(t)=−GRXX(t)−⟨B⟩0δ(t).\delta\langle\mathcal X(t)\rangle=\int dt'\,K(t-t')s(t'),\qquad K(t)=-G_R^{XX}(t)-\langle B\rangle_0\delta(t).

    The commutator uses the zero-source operator XX. The second term is local in time and is often called a contact or seagull term. It can be just as large as the commutator contribution. The formula follows by expanding the Hamiltonian and the observable; it does not require a diagrammatic convention for where to draw the contact.

    For multiple sources, replace BB by the matrix of second source derivatives. For local fields, these are functional derivatives and may contain spatial derivatives of delta functions. Source counterterms, the definition of a density, and metric factors must then be varied consistently as well.

    Electrical response in a specified charge convention

    Use the physical electric charge ee and the ordinary spatial vector potential A\mathbf A. With scalar potential φ\varphi, the fields are E=−∂tA−∇φ\mathbf E=-\partial_t\mathbf A-\boldsymbol\nabla\varphi and B=∇×A\mathbf B=\boldsymbol\nabla\times\mathbf A. This defines the charge and source signs locally; ee is not an undeclared gauge-representation label.

    For NN nonrelativistic particles in volume VV, with coordinate-dependent interactions and potentials, a spatially uniform Ax=AA_x=A gives

    H[A]=∑a=1N(pa,x−eA)2+pa,⊥22m+Vcoord,Ip=em∑a=1Npa,x.H[A]=\sum_{a=1}^N\frac{(p_{a,x}-eA)^2+\mathbf p_{a,\perp}^2}{2m}+V_{\rm coord},\qquad I_p=\frac{e}{m}\sum_{a=1}^N p_{a,x}.

    Define n=N/Vn=N/V and D=ne2/mD=ne^2/m. The spatially averaged physical current is

    j[A]=−1V∂H[A]∂A=IpV−DA.j[A]=-\frac1V\frac{\partial H[A]}{\partial A}=\frac{I_p}{V}-DA.

    The first term is the paramagnetic current; the second is the diamagnetic current. Define the volume-normalized correlator

    GRpp(t)=−iVθ(t)⟨[Ip(t),Ip(0)]⟩0.G_R^{pp}(t)=-\frac{i}{V}\theta(t)\langle[I_p(t),I_p(0)]\rangle_0.

    The complete response to AA and the conductivity are

    δ⟨j(z)⟩=K(z)A(z),K(z)=−GRpp(z)−D,σ(z)=K(z)iz=iz[D+GRpp(z)].\delta\langle j(z)\rangle=K(z)A(z),\qquad K(z)=-G_R^{pp}(z)-D,\qquad \sigma(z)=\frac{K(z)}{iz}=\frac{i}{z}\left[D+G_R^{pp}(z)\right].

    We used temporal gauge φ=0\varphi=0, so E(z)=izA(z)E(z)=izA(z), and take Im⁡z>0\operatorname{Im}z>0 before the real-frequency boundary. This is the full complex conductivity. For nonzero real frequency and a real local contact,

    Re⁡σ(ω)=−Im⁡GRpp(ω)ω.\operatorname{Re}\sigma(\omega)=-\frac{\operatorname{Im}G_R^{pp}(\omega)}{\omega}.

    That last expression alone does not specify a zero-frequency delta function. Dividing a constant contact by iziz produces such a distribution. Bradlyn, Goldstein and Read, §I, Eqs. (1.9)–(1.12), PDF emphasizes this distinction. Their charge is set to one; restoring e2e^2 and using the commutator definition above gives the displayed formula.

    For a lattice band or a Hamiltonian with more general momentum dependence, DD is replaced by V−1⟨∂A2H⟩V^{-1}\langle\partial_A^2H\rangle. It need not equal ne2/mne^2/m, and can depend on the state. The physical source derivative remains the starting point. The transverse current of a clean electron system uses this variation to separate normal-state Drude weight from static magnetic stiffness.

    A confined oscillator tests pure-gauge cancellation

    Consider independent charged oscillators of density nn, each confined on the line by mΩ2q2/2m\Omega^2q^2/2. For a constant AA, the unitary operator UA=eieAqU_A=e^{ieAq} obeys

    UApUA†=p−eA,H[A]=UAH[0]UA†.U_ApU_A^\dagger=p-eA,\qquad H[A]=U_AH[0]U_A^\dagger.

    The confining potential is unchanged and the wavefunctions remain in the same Hilbert-space domain. Every energy level and the equilibrium free energy are independent of constant AA. There can be no equilibrium current response to it.

    Now calculate the response. Since p(t)=p(0)cos⁡Ωt−mΩq(0)sin⁡Ωtp(t)=p(0)\cos\Omega t-m\Omega q(0)\sin\Omega t, the physical paramagnetic susceptibility is

    −GRpp(z)=DΩ2Ω2−z2.-G_R^{pp}(z)=\frac{D\Omega^2}{\Omega^2-z^2}.

    Combining it with the contact gives

    K(z)=Dz2Ω2−z2,σ(z)=−iDzΩ2−z2,K(0)=0.K(z)=\frac{Dz^2}{\Omega^2-z^2},\qquad \sigma(z)=-\frac{iDz}{\Omega^2-z^2},\qquad K(0)=0.

    The cancellation −GRpp(0)=D-G_R^{pp}(0)=D is the gauge-invariance check. Omitting the contact would give K(0)=DK(0)=D, a current induced by a pure gauge. The correct conductivity describes polarization at finite frequency: using the force equation m(q¨+Ω2q)=eEm(\ddot q+\Omega^2q)=eE and j=neq˙j=ne\dot q gives precisely the same σ\sigma.

    This argument has a boundary condition. On a ring of circumference LL, UA(q+L)=eieALUA(q)U_A(q+L)=e^{ieAL}U_A(q) generally changes the boundary twist. A constant AA then represents an observable flux unless eAL∈2πZeAL\in2\pi\mathbb Z. Its free-energy curvature need not vanish. Gauge invariance is not an instruction to cancel every static current response irrespective of geometry. The distinction also appears in Watanabe and Oshikawa, §II.2; their vector potential is the negative of ours, while their physical electric field and current agree.

    Take the transport limit deliberately

    Even within the oscillator kernels, removing confinement and taking zero frequency do not commute:

    lim⁡Ω→0lim⁡z→0K(z)=0,lim⁡z→0lim⁡Ω→0K(z)=−D.\lim_{\Omega\to0}\lim_{z\to0}K(z)=0,\qquad \lim_{z\to0}\lim_{\Omega\to0}K(z)=-D.

    The first limit probes the static polarization of a confined system. The second first permits uniform acceleration. In that order,

    σ(z)=iDz,Re⁡σ(ω)=πDδ(ω).\sigma(z)=\frac{iD}{z},\qquad \operatorname{Re}\sigma(\omega)=\pi D\delta(\omega).

    The unconfined limit is a limit of the response kernels; a free particle on the entire line does not itself have a finite canonical partition function. An actual bulk transport calculation additionally specifies the thermodynamic limit and boundary conditions before its low-frequency limit. At finite spatial momentum, longitudinal static and uniform limits can differ through conservation-law poles, as in diffusion. A static longitudinal pure gauge must be removed together with its scalar-potential transformation; a time-varying uniform vector potential creates an electric field and is a different experiment.

    Weak current relaxation replaces the ballistic pole by a finite-width transport peak only after a dynamical approximation has been justified. The momentum-relaxation calculation derives that mechanism from the slow variables. A self-energy width for an individual excitation does not, by itself, determine the transport relaxation rate.

    Mechanical response has the same second derivative

    Let ss be a chosen dimensionless strain parameter. The extensive force conjugate to it is T[s]=−∂sH[s]\mathcal T[s]=-\partial_sH[s]. Its response kernel per reference volume is

    KT(z)=−1VGRT0T0(z)−1V⟨∂s2H⟩0,T0=−∂sH∣0.K_{\mathcal T}(z)=-\frac1V G_R^{T_0T_0}(z)-\frac1V\langle\partial_s^2H\rangle_0,\qquad T_0=-\left.\partial_sH\right|_0.

    In this equation GRT0T0G_R^{T_0T_0} is the extensive commutator, without the 1/V1/V already included in the electrical definition. A geometric stress density can have further explicit variations from its volume factor and index positions. Those belong to the specified measured operator, not to an optional correction added after extracting transport.

    For a one-coordinate test with reference volume set to one, choose the canonical dilation

    H[s]=e−2sp22m+e2smΩ2q22.H[s]=e^{-2s}\frac{p^2}{2m}+e^{2s}\frac{m\Omega^2q^2}{2}.

    This is a unitary squeezing of the harmonic Hamiltonian. Its frequency and spectrum remain Ω\Omega and En=Ω(n+1/2)E_n=\Omega(n+1/2). With H0=K0+V0H_0=K_0+V_0,

    T0=2(K0−V0),∂s2H∣0=4H0.T_0=2(K_0-V_0),\qquad \left.\partial_s^2H\right|_0=4H_0.

    Write Eˉ=⟨H0⟩=Ωcoth⁡(βΩ/2)/2\bar E=\langle H_0\rangle=\Omega\coth(\beta\Omega/2)/2. The oscillator ladder operators give T0=−Ω(a2+(a†)2)T_0=-\Omega(a^2+(a^\dagger)^2), so it excites transitions at 2Ω2\Omega rather than Ω\Omega. Direct evaluation yields

    −GRT0T0(z)=16Ω2Eˉ4Ω2−z2,KT(z)=4Eˉz24Ω2−z2.-G_R^{T_0T_0}(z)=\frac{16\Omega^2\bar E}{4\Omega^2-z^2},\qquad K_{\mathcal T}(z)=\frac{4\bar E z^2}{4\Omega^2-z^2}.

    The static commutator response 4Eˉ4\bar E is canceled by the contact −4Eˉ-4\bar E. This agrees with the unchanged free energy. Dropping the contact would falsely assign a static restoring force to this isospectral deformation.

    This single oscillator is a check of mechanical source variation, not a viscous fluid. For an actual strain channel whose conjugate force includes a dissipative term −ηs˙-\eta\dot s, the response contains +iωη+i\omega\eta in our Fourier convention. One must first remove the channel's equilibrium elastic response, fix strain normalization, and account for conserved-density mixing before taking that slope. These steps are developed for viscosity. Bradlyn, Goldstein and Read derive the analogous stress contact from strain variation in §I, Eqs. (1.13)–(1.16), and §III.1. Their strain-rate response is distinct from the strain response KTK_{\mathcal T} used here.

    Two numerical cancellations with a cutoff check

    The companion in examples/thermal/linear-response/response-contacts-sumrules/ uses m=1.4m=1.4, Ω=0.9\Omega=0.9, β=0.8\beta=0.8, e=0.8e=0.8 and n=0.7n=0.7. A thermal Lehmann calculation gives the electrical paramagnetic static response 0.320.32, canceled by −D=−0.32-D=-0.32. The mechanical terms approach ±5.21415650006\pm5.21415650006.

    At 20, 32 and 48 basis states, the residual mechanical responses are approximately −0.0100-0.0100, −4.48×10−5-4.48\times10^{-5} and −2.21×10−8-2.21\times10^{-8}. At 72 states, the residual is below 2×10−132\times10^{-13}. The electrical cancellation converges as well, and the full complex-frequency current response agrees with the force-equation result.

    Separately, diagonalizing the finite-source Hamiltonians and differentiating their ground-state energies gives curvatures below 2×10−122\times10^{-12} for the tested source steps, consistent with unitary equivalence. The finite-basis residuals explain why a contact must not be tuned to cancel an unconverged commutator: the source-coupled Hamiltonian fixes its coefficient.

    Summary

    A Kubo calculation varies both state and measured operator. Minimal electric coupling gives K=−GRpp−DK=-G_R^{pp}-D and σ=K/(iz)\sigma=K/(iz). The oscillator has pure-gauge cancellation; removing confinement first produces a ballistic pole. Mechanical strain obeys the same second-derivative rule, with geometric factors fixed by the stress definition.

    Exercises

    1. Compare two gauges for the same pulse. For a smooth, spatially uniform electric pulse, take E=−A˙E=-\dot A with AA initially zero. Show that Hℓ=H0−eE(t)qH_\ell=H_0-eE(t)q and Hv=(p−eA(t))2/(2m)+mΩ2q2/2H_v=(p-eA(t))^2/(2m)+m\Omega^2q^2/2 give the same physical current. Identify the extra term in a time-dependent unitary transformation.

    Solution

    Set ψv=UAψℓ\psi_v=U_A\psi_\ell with UA=eieAqU_A=e^{ieAq}. The transformed Schrödinger equation has Hamiltonian

    UAHℓUA†+iU˙AUA†=Hv−eEq−eA˙q=Hv.U_AH_\ell U_A^\dagger+i\dot U_AU_A^\dagger=H_v-eEq-e\dot A q=H_v.

    The two scalar terms cancel because E=−A˙E=-\dot A. Moreover UA†(p−eA)UA=pU_A^\dagger(p-eA)U_A=p, so ⟨e(p−eA)/m⟩v=⟨ep/m⟩ℓ\langle e(p-eA)/m\rangle_v=\langle ep/m\rangle_\ell. Omitting iU˙AUA†i\dot U_AU_A^\dagger would compare different electric fields; omitting the −e2A/m-e^2A/m current term would compare different observables. The equality holds for the full quantum evolution, not only to first order in the pulse.

    2. A response made entirely of a contact. A particle is confined in a one-dimensional box of length L=L0(1+s)L=L_0(1+s). In fixed dimensionless coordinates the Hamiltonian is H[s]=(1+s)−2H0H[s]=(1+s)^{-2}H_0. Find the response of T=−∂sH\mathcal T=-\partial_sH to a slow change of ss with level populations held fixed. Compare it with the response at fixed temperature after equilibration.

    Solution

    At s=0s=0, T0=2H0T_0=2H_0 and ∂s2H=6H0\partial_s^2H=6H_0. Since T0T_0 commutes with H0H_0, its retarded commutator vanishes. Fixed populations therefore give

    KT(0)=−6⟨H0⟩.K_{\mathcal T}(0)=-6\langle H_0\rangle.

    This is precisely the derivative of ⟨T[s]⟩=2(1+s)−3⟨H0⟩\langle\mathcal T[s]\rangle=2(1+s)^{-3}\langle H_0\rangle at fixed populations. At fixed temperature, the occupations depend on En(s)=En(0)/(1+s)2E_n(s)=E_n(0)/(1+s)^2. Their derivative contributes 4βVar⁡(H0)4\beta\operatorname{Var}(H_0), giving

    d⟨T⟩ds∣T=−6⟨H0⟩+4βVar⁡(H0).\left.\frac{d\langle\mathcal T\rangle}{ds}\right|_T=-6\langle H_0\rangle+4\beta\operatorname{Var}(H_0).

    The first term is a genuine contact response and the second requires thermal population rearrangement. Neither is a viscous loss coefficient. The physical force on the wall is T/L0\mathcal T/L_0, since the source was the dimensionless fractional length change.

    References

    • Bradlyn, Barry, Moshe Goldstein, and N. Read. “Kubo Formulas for Viscosity: Hall Viscosity, Ward Identities, and the Relation with Conductivity,” Physical Review B 86, 245309 (2012). Version 2 PDF, §I, Eqs. (1.9)–(1.16), printed pp.3–4; §III.1, stress variation and contact terms. Their electrical charge is one; their mechanical transport kernel responds to strain rate.
    • Watanabe, Haruki, and Masaki Oshikawa. “Generalized ff-Sum Rules and Kohn Formulas on Non-linear Conductivities,” Physical Review B 102, 165137 (2020). arXiv:2003.10390v3, §II.2, discussion after Eq. (21), on open and periodic boundaries. They use E=+A˙E=+\dot A and j=+V−1∂AHj=+V^{-1}\partial_AH; setting their AA to minus ours aligns the physical fields and currents.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.