A model can reproduce a spectrum accurately while leaving a plasma property undetermined. It can also return a sharply constrained parameter that compensates for missing physics. The two problems are different: the first is an identifiability problem inside a model, while the second concerns whether the model describes the observable being fitted.
We will demonstrate both with synthetic particle spectra from the chapter's expanding massless gas. The calculation fits a temperature and an effective volume with explicit correlated errors, checks the result by eliminating one parameter analytically, and then changes the particle-conversion prescription. No experimental data are fitted, and none of the numbers is an extraction of QCD transport.
Preparation: The Bjorken forward evolution, the particle conversion calculation, Gaussian likelihoods and linear algebra. The toy gas has degeneracy , Boltzmann statistics and zero chemical potential.
Write the forward model before choosing a fitting method
For a homogeneous Bjorken patch converted at temperature , the equilibrium spectrum is
Here is the proper volume per unit spacetime rapidity. The spectrum is a yield per momentum rapidity and per transverse-momentum area, with dimension minus two. A differential spectrum at a selected momentum is not a yield integrated over a finite bin; the synthetic observations below are explicitly point values.
The forward calculation supplies the conversion time by solving the cooling equation. Its stated parameters are
At the chosen conversion temperature, it gives
The volume has been converted using . It equals approximately . Keeping these units explicit prevents a volume conversion error from masquerading as a fitted multiplicity normalization.
In a realistic collision analysis, the analogous forward map includes fluctuating initial conditions, transport, the equation of state, particle conversion, hadronic evolution and an experimental measurement definition. Bernhard et al., arXiv:1605.03954v2, §§II–III provide a concrete published multistage calibration. Their physical model and their uncertainty prescription are not the toy model used here. We retain the same logical separation between inputs, predictions and statistical comparison.
State the correlated error model
Choose twelve equally spaced momenta from to . Denote the logarithm of the spectrum in fixed units by , and its synthetic observed value by . We fit
The spectrum reference unit is , so is dimensionless. The choice of reference units shifts logarithms by constants without changing predictions.
Let the noise contain an independent component, a common normalization shift and a correlated tilt:
All , and are independent standard normal variables. Choose
These are standard deviations in log space, approximately fractional errors for small fluctuations. Exponentiating produces positive synthetic spectra. This is a declared log-normal measurement model, not a Poisson counting model.
Marginalizing the two common shifts gives the covariance
The normalization error moves all points together. The tilt correlates points on the same side of the mean momentum and anticorrelates opposite sides. Neither effect can be represented correctly by attaching unrelated error bars to the twelve points.
For a fixed covariance, the Gaussian log likelihood is
The last two terms do not affect this fit because the covariance is parameter independent. They cannot generally be dropped when comparing parameter-dependent covariance models. Bayesian inference multiplies this likelihood by a stated prior; a least-squares optimum alone is not a posterior distribution. Bernhard et al., §III.3, Eqs. (28)–(30) illustrate that separation and explicitly discuss the limits of their chosen covariance ansatz.
Recover the identifiable parameters
The companion generates one noisy realization with a fixed random seed and minimizes the quadratic likelihood. It obtains
There are twelve observations and two fitted parameters. This one realization is a recovery demonstration, not a test of repeated-sample interval coverage. The complete synthetic observations, covariance and seed are saved in examples/thermal/hot-qcd/fluid-inference/results.json.
For local uncertainty estimates define the response matrix . The Bessel derivative identity gives
The superscript distinguishes the dimensionless momentum from the observed log spectrum. The local Fisher matrix and covariance are
They describe the locally linearized specified likelihood. They do not include unknown model errors, uncertain experimental covariance, or broad-prior effects. The analytic Jacobian independently agrees with the covariance obtained from numerical fit derivatives.
For the noiseless central spectrum, the sensitivity to the assumed covariance is:
| Error model | Local relative error in | Local relative error in |
|---|---|---|
| Full correlated covariance | 3.143% | 0.226% |
| Same marginal errors, correlations discarded | 2.535% | 0.580% |
| Independent component only | 0.413% | 0.094% |
Discarding correlations does not move every uncertainty in the same direction. A common normalization shift is degenerate with volume but largely cancels from shape ratios. Replacing it by independent errors spuriously averages down the normalization uncertainty and adds noise to the slope determination. Removing the common uncertainties entirely makes both estimates overconfident in this example.
A separate solution checks the numerical optimizer. At fixed temperature write
where is the predicted log spectrum at the reference volume. Differentiating the quadratic likelihood with respect to the common amplitude gives
Substituting this expression leaves a one-dimensional temperature minimization. It agrees with the two-parameter fit within in temperature and fractionally in volume. This one-dimensional minimization checks the two-parameter optimization independently.
A precise spectrum need not determine the viscosity
Suppose the area and conversion temperature are known. The equilibrium spectrum then measures the conversion time, but it does not separately measure the initial temperature and viscosity ratio. Rearranging the analytic cooling solution at that time gives an exact curve of indistinguishable inputs:
For the central spectrum, an ideal evolution starting at has the same conversion time and equilibrium spectrum as the viscous evolution starting at . A more precise measurement of that same spectrum cannot distinguish the two.
The finite-difference Jacobian of the full map from to twelve log spectra has rank one: every change acts through the same volume normalization. In the program, the ratio of its smaller to larger noise-weighted singular value is about , consistent with differentiation roundoff. The analytic relation proves the degeneracy; that small numerical ratio is only a check.
The figure contrasts the forward cooling histories with the family of inputs yielding the same output. Each history ends at its own conversion time. Points along the inverse-model curve remain subject to the gradient and pressure checks of the fluid approximation.
Left: the declared massless-gas histories, with the common initial state and . Right: the exact degeneracy at the viscous benchmark's fixed conversion time. The line traces histories that the equilibrium readout cannot distinguish.
If the viscosity were independently known to equal its input value, the fitted volume would determine the initial temperature.
Converting volume to time gives . This recovery is conditional. A narrow prior on viscosity could produce a similar-looking initial-temperature constraint, but the prior would be supplying the missing information.
Flow harmonics, other collision systems, early-time electromagnetic emission or a shear-sensitive distribution can add different sensitivities. Whether they break a particular degeneracy is a calculation of the enlarged response matrix, not a consequence of merely adding more observable names. An uncertain area would introduce a further normalization degeneracy.
Fit the wrong particle-conversion model
The equilibrium readout discards the residual shear of the viscous fluid. To test that assumption, generate a second, noiseless synthetic spectrum using the first-order shear correction derived in particlization. For the axisymmetric stress, define and . The corrected spectrum is
For the first-order Bjorken stress,
This correction preserves the appropriate local energy matching and encodes the residual shear to the retained order. The underlying polynomial correction is not uniformly small or positive at arbitrarily large local momenta. We use it only as a specified first-order spectral diagnostic over the stated finite momentum range, not as an exact positive distribution everywhere.
At the twelve selected momenta its integrated fractional correction ranges from to . The total multiplicity correction vanishes when the formal first-order spectrum is integrated over all transverse momenta, but its shape changes. Fitting these noiseless corrected points with the isotropic spectrum and the same assumed covariance gives
The temperature moves by about 1.46%, more than six times the wrong model's local temperature error, while the volume moves by about minus 4.57%. A quadratic residual of this size with ten residual dimensions would not constitute overwhelming evidence against the model in a noisy realization. Here it is a deterministic mismatch diagnostic, so it is not itself a random chi-square draw or a coverage calculation. Fitting the same points with their generating corrected shape, holding and fixed in the correction while allowing to follow the fitted temperature, recovers the input volume and temperature to numerical precision.
The mechanism is transparent after linearization. If the omitted physics changes the log spectrum by , then
This component is absorbed into biased fitted parameters. Only the remainder orthogonal to the model's response directions contributes to the minimized residual. A small residual can therefore coexist with a large bias along a well-measured direction. Varying physically motivated conversion prescriptions and checking observables withheld from the fit address a different question from refining the optimizer.
What a larger inference calculation must add
A serious collision analysis must specify centrality selection, particle species, acceptance, event fluctuations and the covariance of the reported measurements. It must propagate uncertainty from initial conditions, the equation of state, transport and conversion rather than varying a preferred parameter in isolation. Those uncertainties can be correlated across momenta and systems.
If an expensive forward model is replaced by an emulator, interpolation uncertainty also enters the likelihood. Validation requires held-out forward calculations, not only agreement at training points. Bernhard et al., §III.2 give an example of such validation. The present analytic spectrum is fast enough to fit directly, so no emulator error or validation claim is introduced.
Model discrepancy should be specified with enough structure to represent plausible missing physics, while recognizing that a very flexible discrepancy can remove parameter identifiability. Posterior checks, sensitivity to priors and alternative model assumptions complement numerical convergence; none can be replaced by a single best-fit curve.
Summary
The synthetic calculation recovers the parameters that the spectrum actually measures, demonstrates an exact initial-temperature–viscosity degeneracy, and shows a calculable bias from omitting shear at conversion. Correlated uncertainties determine which spectral directions are well measured. Precision within a specified model and confidence in that model are separate conclusions.
Exercises
A normalization error that does not average away
Suppose the temperature is known and the only unknown is the log volume. For log-spectrum points with covariance , find the variance of the fitted log volume. Compare it with treating the same diagonal errors as independent.
Solution
Subtract the known spectral shape. The mean of the remaining points estimates the log volume. Its independent noise variance is , while the common shift contributes without averaging down. Thus
The same result follows from . If one discards correlations but keeps each marginal variance, the reported result instead becomes . As the number of points increases, that incorrect estimate tends to zero while the actual normalization uncertainty has a nonzero floor.
A missing effect that leaves no residual
Let an omitted small correction to the log spectrum be for a fixed two-component vector . Determine the leading fitted parameter bias and the minimized mismatch residual. What would fitting an independent observable accomplish?
Solution
With full-rank response for the two identifiable parameters,
The leading residual is , so the fit absorbs the entire omitted effect. This is an exact statement within the linearized model, even at arbitrarily high precision. A new observable helps if its missing-physics shift is not the shift predicted by the same parameter displacement. If it has the same degeneracy, more points only repeat the ambiguity. Establishing which case holds requires calculating its forward response and uncertainty.
References
- J. E. Bernhard, J. S. Moreland, S. A. Bass, J. Liu and U. Heinz, Applying Bayesian parameter estimation to relativistic heavy-ion collisions: simultaneous characterization of the initial state and quark-gluon plasma medium, Physical Review C 94, 024907 (2016), arXiv:1605.03954v2. §II for the multistage forward model; §III.2 for emulation and held-out validation; §III.3, Eqs. (28)–(30), for likelihood, prior and uncertainty assumptions. The synthetic covariance and analytic model on this page are separately defined.