- Home
- Library
- Thermal and Nonequilibrium Field Theory
- Thermal Transitions, Bubble Growth, and Cosmology
- Gauge Dependence and Physical Transition Criteria
Gauge Dependence and Physical Transition Criteria
Two people choose different gauges, minimize the same one-loop thermal potential, and obtain different transition points. Which calculation is wrong? The problem can be the minimization itself: solving a truncated potential exactly retains some higher-order terms while omitting others required by the gauge identity. We will exhibit this effect in a specified Abelian Higgs theory, calculate the gauge-independent first correction to coexistence, and measure the order of the spurious gauge dependence.
Preparation: Gauge-parameter independence, thermal potentials, and dimensional reduction. Gauge fixing determines field coordinates; a phase comparison requires free energies.
A model with two stable tree-level phases
Work with a noncompact Abelian Higgs theory in three Euclidean spatial dimensions, after hard thermal modes and the electric scalar have been matched out. Take one complex scalar of unit representation charge and
This polynomial is gauge invariant: its argument represents the radial background, not an added gauge-variant interaction. The dimensions are , , and . The negative quartic and positive sextic give a tree barrier. The coefficients are specified inputs of this static EFT; we assume other matched operators are small over the field range used. They are not being derived from the minimal four-dimensional Abelian Higgs model.
The dimensionless action defines a free-energy density of dimension three. Its contribution to the physical thermal density is , plus a hard identity coefficient common to the phases. A transition in below is therefore a transition in EFT parameter space. Obtaining a full-theory additionally requires the matching trajectory .
At tree level, and a nonzero minimum coexist at
Their radial curvatures are and , both positive. Thus a small-loop expansion around either phase is possible. The tree barrier lets us examine gauge consistency while both phases are already present at leading order.
Count the gauge, scalar and ghost determinants
Expand and use the background family with fixed ,
The minus sign in the Euclidean gauge condition cancels the mixing from . The background is held fixed when forming the Faddeev–Popov operator. The ghost is one complex Grassmann pair, not a physical thermal species.
Define the following squared masses:
The polynomial defines continuously at . Two spatial vector eigenvalues are transverse to momentum; their mass is . The longitudinal eigenvalue becomes after removing a field-independent normalization. Its one real-boson determinant and the complex ghost's minus two determinants leave minus one. Dimensional regularization then gives
Each mass denotes the positive square root in a stable neighborhood. This counting is the static counterpart of the scalar, vector and ghost trace logs in Patel–Ramsey-Musolf, §II.3, Eq.(24). The electric mode has already been integrated out; it must not be counted again as a third spatial polarization.
Between the minima, can be negative. We do not make this expression real by taking absolute values and then globally minimize it. All calculations below use the real neighborhoods of the two stable branches. The tree barrier is well defined, but its loop correction throughout the unstable interpolation is not supplied by this Gaussian formula.
Verify the Nielsen identity in this model
Write , where counts loops and is set to one after organizing the expansion. BRST invariance gives the homogeneous Nielsen identity
Its meaning is local in field space: changing the gauge shifts the field coordinate while leaving an exactly stationary value unchanged. It assumes a consistent gauge-fixed measure and renormalization, not an arbitrary truncation. The ordinary background is not itself an observable.
Here the first coefficient can be calculated explicitly. Differentiating the two unphysical masses gives
The second equality uses . It verifies the identity away from a stationary point as well as at one. A separate loop-integral representation is
Radial integration gives for the integral. The companion evaluates it directly and compares with a finite difference in of the determinant. This checks the ghost multiplicity and gauge dependence without assuming the closed-form Nielsen coefficient.
At a nonzero tree extremum, , so and their contributions cancel. At the symmetric extremum , the massless vector/ghost determinants are scaleless and . Both branch values of are gauge independent.
There is an important nonuniform limit. At the broken tree extremum, for . Its divergence as warns against interchanging the Landau-gauge limit, derivatives and an expansion near a massless Goldstone mode. We use finite positive of order one. Arbitrarily large can also spoil the assumed hierarchy. Neither limit is an improvement obtained for free.
Expand the stationary value, not just the potential
For a nondegenerate tree minimum at fixed parameters, stationarity determines
Expanding its free energy through the next two orders gives
At first order, evaluate at the tree minimum; the field shift does not contribute because . At second order, the shift term must accompany the complete . The cancellations follow from the same Nielsen identity order by order; see Patel–Ramsey-Musolf, §§II.5–III.1, Eqs.(33)–(43).
Apply this to coexistence by expanding . Since the derivative of the tree free-energy difference with respect to is ,
The cancellation is explicit before choosing any gauge parameter. The field coordinate at coexistence instead has
Its gauge dependence is expected. A ratio made from and a temperature does not become gauge invariant simply because was calculated consistently.
Compare with numerical minimization of the truncated branches
Choose a reference mass and the dimensionless inputs
Then , , and
For comparison, solve the derivative of exactly within the broken stable neighborhood, and equate its value to the symmetric branch. At :
| Gauge parameter | Naive | Naive | Consistent through one loop |
|---|---|---|---|
All masses used on the solved branches have nonnegative squared values, with positive scalar masses. The computation does not continue through the unstable radial interval. The two prescriptions first differ beyond the one-loop accuracy of this calculation.
We can test the order of the mismatch. At a stationary point of the truncated potential,
Thus the unwanted gauge variation starts at when the expansion is regular. The spread in naive across the four gauges is , , and for . Dividing by approaches a nonzero constant. A small gauge spread is consequently a useful diagnostic of one missing class of terms, not an error bar on every omitted contribution.
When the barrier is generated by gauge fluctuations
The preceding expansion cannot be transplanted unchanged to a positive-quartic model whose broken minimum exists only because of gauge loops. For a four-dimensional radial field , a schematic radiative potential contains
Here is the radial quartic normalization in this separate gauge example. Balancing terms gives and . For the useful counting , the background is , the vector masses are , the scalar mass is , and the entire leading barrier is . The transverse gauge determinant must be included at leading order, not treated as a small displacement of a nonexistent tree minimum. This is the counting explained in Arnold–Espinosa, §2.2, Eq.(2.17) and Table 1, PDF.
The electric determinant also matters: at , its Debye mass and Higgs-induced mass are both . Its dependence is not uniformly represented by a small-field quartic Taylor expansion. It must be retained or matched with a controlled expansion appropriate to the field range. The cubic term gives the parametric field and barrier scales derived above.
Integrate out the genuinely heavier modes, construct the leading action in this new counting, and expand the remaining extrema and observables consistently. Terms promoted by infrared enhancement must accompany the reorganized Nielsen identities. If a scalar curvature vanishes, or non-Abelian magnetic fluctuations enter without a small ratio, a reduced theory can remain valid while its perturbative solution fails. The next article describes what to measure then.
Summary
In the specified Abelian Higgs EFT, the Goldstone, longitudinal and ghost determinants give an explicit Nielsen identity. Evaluating one-loop branch free energies at their tree extrema yields a gauge-independent shift of coexistence. Exact minimization of the truncated branches adds incomplete higher orders, producing the measured quadratic gauge variation. Gauge-dependent coordinates, missing higher-order uncertainty and radiatively reorganized counting are separate issues.
Exercises
1. Move the field without moving the free energy
At fixed on the broken tree branch, use the one-loop identity to find . What happens to through first order?
Solution
Differentiate at fixed tree parameters. Differentiating with respect to , then setting , gives . Therefore
The coordinate shifts although the free energy does not. Integrating between two finite positive gauges gives . The singular derivative near does not justify a uniform expansion of other quantities there.
2. Translate an EFT crossing into a temperature
Suppose matching supplies with , while the other EFT coefficients may be treated as constant over the small interval of interest. Find the first correction to the critical temperature. Explain what changes if the matching coefficients also vary appreciably.
Solution
The leading crossing is . Writing and expanding gives
This is a temperature prediction only after specifying the matching map. More generally write the tree branch difference as along the full map. Then , provided the denominator is nonzero. Derivatives of and any additional coefficients enter that total derivative. A tangential crossing requires a different expansion. Multiplication by to form the physical free energy does not change this first-order root formula because at the leading crossing.
References
- P. Arnold and O. Espinosa, “The Effective Potential and First-Order Phase Transitions: Beyond Leading-Order,” Physical Review D 47, 3546 (1993), erratum 50, 6662 (1994); arXiv:hep-ph/9212235v2, PDF, §2.2, printed pp.7–10, Eqs.(2.15)–(2.18) and Table 1. These passages establish electric resummation and radiative-barrier counting. Their coefficient is for the radial quartic used in the final section.
- H. H. Patel and M. J. Ramsey-Musolf, “Baryon Washout, Electroweak Phase Transition, and Perturbation Theory,” Journal of High Energy Physics 07 (2011), 029, arXiv:1101.4665v2, §§II.3, II.5–II.6 and III.1, Eqs.(24), (33)–(43). We use their potential identity . The three-dimensional sextic model, explicit integral and numerical comparison above are calculated here rather than taken from their Standard Model examples.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.