Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Gauge-Parameter Independence

    A gauge-fixed propagator can change when ξ\xi changes even though a physical prediction does not. The cancellation occurs in the complete observable, and it can require an unphysical scalar exchange as well as the vector exchange.

    We derive the restricted BRST argument, check conserved-source exchange, and calculate a broken-phase example in which both pieces are indispensable. This page supplies the gauge-independence preparation for the Goldstone equivalence theorem; that theorem needs additional high-energy and external-state reasoning.

    What the BRST argument actually proves

    Use the nilpotent BRST differential and gauge-fixing fermion. Keep ss fixed and take a family Sξ=Sinv+sΨξS_\xi=S_{\rm inv}+s\Psi_\xi. Let O\mathcal O be an even, ξ\xi-independent, BRST-closed insertion, sO=0s\mathcal O=0. In the normalized Lorentzian integral,

    ∂ξ⟨O⟩ξ=i⟨O s(∂ξΨξ)⟩ξ,c.\partial_\xi\langle\mathcal O\rangle_\xi =i\langle\mathcal O\,s(\partial_\xi\Psi_\xi)\rangle_{\xi,c}.

    The connected subscript includes the subtraction from differentiating ZξZ_\xi. If ⟨sX⟩ξ=0\langle sX\rangle_\xi=0 holds, then

    O s(∂ξΨξ)=s(O ∂ξΨξ),⟨s(∂ξΨξ)⟩ξ=0,\begin{aligned} \mathcal O\,s(\partial_\xi\Psi_\xi) &=s(\mathcal O\,\partial_\xi\Psi_\xi),\\ \langle s(\partial_\xi\Psi_\xi)\rangle_\xi&=0, \end{aligned}

    and the derivative vanishes.

    The assumptions are substantive: the measure and renormalization must respect the BRST identity, the integration domain must have no unaccounted BRST boundary, and the observable and its boundary data must remain fixed. If the observable definition itself depends on ξ\xi, its explicit derivative must also be included. The general gauge-fermion variation and its integration-by-parts proof are given in Fuster, Henneaux and Maas, §8, Eqs.(8.9)–(8.15).

    For physical scattering this argument must be combined with the state quotient, external-leg normalization and any necessary infrared prescription. It is not a statement that arbitrary off-shell Green functions are independent of ξ\xi.

    Conserved sources remove the photon gauge term

    For free Maxwell theory the covariant propagator is

    Dμν(ξ)(p)=−iημνp2+i0+i(1−ξ)pμpν(p2+i0)2.D_{\mu\nu}^{(\xi)}(p) =\frac{-i\eta_{\mu\nu}}{p^2+i0} +i(1-\xi)\frac{p_\mu p_\nu}{(p^2+i0)^2}.

    The numerator and boundary value together define the tensor distribution; no separate infrared extension of a scalar double pole is being assumed. For two conserved source factors, p⋅J=p⋅J′=0p\cdot J=p\cdot J'=0,

    JμDμν(ξ)J′ν=−i J⋅J′p2+i0.J^\mu D_{\mu\nu}^{(\xi)}J'^\nu =\frac{-i\,J\cdot J'}{p^2+i0}.

    The result is independent of ξ\xi. For nonconserved sources the longitudinal term remains, as it should: A⋅JA\cdot J alone is not a gauge-invariant probe. Boundary flux must be included when conservation is obtained by integration by parts on a finite region.

    This is a free exchange kernel. A complete interacting amplitude also contains the vertex, self-energy and other diagrams required at the chosen perturbative order.

    Derive the broken-phase propagators

    Use the Abelian Higgs action with

    Linv=−14F2+∣DΦ∣2−λ(∣Φ∣2−v2/2)2,Dμ=∂μ−igAμ,Φ=v+h+iχ2,m=gv,Mh2=2λv2.\begin{aligned} \mathcal L_{\rm inv} &=-\frac14F^2+|D\Phi|^2 -\lambda(|\Phi|^2-v^2/2)^2,\\ D_\mu&=\partial_\mu-igA_\mu,\qquad \Phi=\frac{v+h+i\chi}{\sqrt2},\\ m&=gv,\qquad M_h^2=2\lambda v^2. \end{aligned}

    Work perturbatively around v>0v>0, with the vacuum condition and parameters fixed consistently. The quadratic scalar kinetic term contains

    12(∂h)2+12(∂χ)2−mA⋅∂χ+12m2A2.\frac12(\partial h)^2 +\frac12(\partial\chi)^2 -mA\cdot\partial\chi+\frac12m^2A^2.

    Choose Fξ=∂⋅A+ξmχF_\xi=\partial\cdot A+\xi m\chi. Expanding −Fξ2/(2ξ)-F_\xi^2/(2\xi) and integrating the mixed term by parts cancels −mA⋅∂χ-mA\cdot\partial\chi. The resulting quadratic action is

    L2=−14F2+12m2A2−12ξ(∂⋅A)2+12(∂h)2−12Mh2h2+12(∂χ)2−12ξm2χ2.\begin{aligned} \mathcal L_2={}&-\frac14F^2+\frac12m^2A^2 -\frac1{2\xi}(\partial\cdot A)^2\\ &+\frac12(\partial h)^2-\frac12M_h^2h^2 +\frac12(\partial\chi)^2-\frac12\xi m^2\chi^2. \end{aligned}

    For ξ>0\xi>0 the vacuum inverses have ordinary positive unphysical mass squared. Decompose away from p2=0p^2=0 into PT=η−pp/p2P^{\rm T}=\eta-pp/p^2 and PL=pp/p2P^{\rm L}=pp/p^2. The vector quadratic operator is

    K=(m2−p2)PT+(m2−p2/ξ)PL.K=(m^2-p^2)P^{\rm T} +(m^2-p^2/\xi)P^{\rm L}.

    Its inverse times ii gives

    Dμν(ξ)(p)=−ip2−m2+i0[ημν−(1−ξ)pμpνp2−ξm2+i0],Dχ(p)=ip2−ξm2+i0,Dh(p)=ip2−Mh2+i0.\begin{aligned} D^{(\xi)}_{\mu\nu}(p) &=\frac{-i}{p^2-m^2+i0} \left[\eta_{\mu\nu} -\frac{(1-\xi)p_\mu p_\nu}{p^2-\xi m^2+i0}\right],\\ D_\chi(p)&=\frac{i}{p^2-\xi m^2+i0}, \qquad D_h(p)=\frac{i}{p^2-M_h^2+i0}. \end{aligned}

    These are understood as analytic functions continued with the common Feynman prescription, rather than unrelated finite-ϵ\epsilon substitutions during algebraic cancellations. The ghost action has the same unphysical mass ξm2\xi m^2 and the interaction −ξgm cˉhc-\xi gm\,\bar c h c.

    A gauge-invariant probe needs both exchanges

    In a patch where Φ≠0\Phi\ne0, write Φ=∣Φ∣eiθ\Phi=|\Phi|e^{i\theta}. Since θ↦θ+gα\theta\mapsto\theta+g\alpha,

    Bμ=Aμ−1g∂μθB_\mu=A_\mu-\frac1g\partial_\mu\theta

    is gauge invariant. Its linearization about the chosen vacuum is

    Bμ=Aμ−1m∂μχ+O(two fluctuation fields).B_\mu=A_\mu-\frac1m\partial_\mu\chi +O(\hbox{two fluctuation fields}).

    Couple a classical probe by JμBμJ^\mu B_\mu. At linear order, integration by parts gives J⋅A+KχJ\cdot A+K\chi, where

    K=∂⋅Jm.K=\frac{\partial\cdot J}{m}.

    Indeed δ(J⋅A+Kχ)=(−∂⋅J+mK)α\delta(J\cdot A+K\chi)=(-\partial\cdot J+mK)\alpha after integration by parts. Thus JJ need not itself be conserved, but its scalar source is fixed. The nonlinear completion using θ\theta supplies the additional terms needed beyond this quadratic calculation.

    The Gaussian source-exchange kernel is

    DμνB=Dμν(ξ)+pμpνm2Dχ.\mathcal D^B_{\mu\nu} =D^{(\xi)}_{\mu\nu} +\frac{p_\mu p_\nu}{m^2}D_\chi.

    One can see the cancellation before doing any source contraction:

    Dμν(ξ)=−ip2−m2(ημν−pμpνm2)−ipμpνm2(p2−ξm2),DμνB=−ip2−m2(ημν−pμpνm2).\begin{aligned} D^{(\xi)}_{\mu\nu} ={}&\frac{-i}{p^2-m^2} \left(\eta_{\mu\nu}-\frac{p_\mu p_\nu}{m^2}\right) -\frac{i p_\mu p_\nu}{m^2(p^2-\xi m^2)},\\ \mathcal D^B_{\mu\nu} ={}&\frac{-i}{p^2-m^2} \left(\eta_{\mu\nu}-\frac{p_\mu p_\nu}{m^2}\right). \end{aligned}

    The vacuum boundary values are restored after the rational cancellation. The pole at p2=ξm2p^2=\xi m^2 disappears; the physical massive-vector pole remains. For arbitrary probe vectors,

    JμDμνBJ′ν=−ip2−m2+i0[J⋅J′−(p⋅J)(p⋅J′)m2].J^\mu\mathcal D^B_{\mu\nu}J'^\nu =\frac{-i}{p^2-m^2+i0} \left[J\cdot J'-\frac{(p\cdot J)(p\cdot J')}{m^2}\right].

    This is a tree-level broken-phase cancellation for a specified invariant probe, not merely an assertion about a conserved current. The retained program inverts the quadratic vector matrix and adds the scalar exchange at several ξ\xi, including nonconserved probes. Omitting the scalar term leaves an explicitly varying result.

    Because the probe contains time derivatives, DB\mathcal D^B denotes the covariant source-derived kernel. A canonical TT product of constrained Proca components differs by an equal-time contact; the distinction is derived on the Proca page. It is not legitimate to replace one ordering by the other silently.

    What can still depend on the gauge parameter?

    The elementary AAAA propagator above depends on ξ\xi off shell. A fixed mean value of the gauge-variant Cartesian field hh is likewise not a BRST-invariant observable, so the argument does not make the off-shell effective potential gauge independent. The location of a minimum in such field coordinates can move when ξ\xi changes.

    Values of physical observables at consistently treated stationary solutions, physical poles and amplitudes require the appropriate identities and complete perturbative order. A curvature of a gauge-dependent potential is not automatically a pole mass. Mixing orders, varying an external-state convention, or dropping ghost/Goldstone diagrams can spoil a cancellation without disproving the identity.

    Finally, restricting a nonperturbative integral to a region with a field-space boundary demands a new boundary analysis. The local perturbative BRST proof does not settle the global gauge-fixing problem.

    Summary

    BRST-exact changes of gauge fixing leave fixed BRST-closed observables unchanged under stated measure and domain assumptions. In a broken phase, an invariant source can couple to both the vector and the would-be Goldstone; their unphysical poles cancel in the complete kernel.

    Exercises

    1. Vary the correct gauge fermion. For Fξ=∂⋅A+ξmχF_\xi=\partial\cdot A+\xi m\chi, compute ∂ξΨξ\partial_\xi\Psi_\xi with mm fixed.

    Solution

    From Ψξ=∫cˉ(Fξ+ξb/2)\Psi_\xi=\int\bar c(F_\xi+\xi b/2),

    ∂ξΨξ=∫d4x cˉ(mχ+b/2).\partial_\xi\Psi_\xi=\int d^4x\,\bar c(m\chi+b/2).

    Therefore ∂ξS=s(∂ξΨ)\partial_\xi S=s(\partial_\xi\Psi) includes the variation of the scalar gauge condition as well as the auxiliary Gaussian. Keeping only cˉb/2\bar cb/2 would be incomplete.

    2. Test a purely longitudinal probe off shell. Set Jμ=J′μ=pμJ^\mu=J'^\mu=p^\mu, with p2≠m2,ξm2p^2\ne m^2,\xi m^2. Compare vector-only and complete exchange.

    Solution

    The vector-only answer is −iξp2/(p2−ξm2)-i\xi p^2/(p^2-\xi m^2). The scalar source contributes i(p2)2/[m2(p2−ξm2)]i(p^2)^2/[m^2(p^2-\xi m^2)]. Their sum is

    ip2m2,\frac{i p^2}{m^2},

    independent of ξ\xi. It has no massive pole because a pure-gradient source does not excite the on-shell transverse massive-vector residue. The remaining polynomial is a contact contribution to this source response.

    References

    • A. Fuster, M. Henneaux and A. Maas, BRST-Antifield Quantization: A Short Review, §§6–8: gauge-fermion dependence, measure conditions and exact insertions. The quadratic Higgs source cancellation is derived directly above.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.