- Home
- Library
- Symmetry and Gauge Theory
- Currents, Background Fields, and Ward Identities
- Background Gauge Fields and Global Symmetry
Background Gauge Fields and Global Symmetry
A background field probes a current without becoming a quantum variable itself. The second derivative of the generating functional measures how that current responds. For a charged scalar, this response contains both a two-current correlation and a local term from the action's quadratic dependence on the background. Their cancellation in a pure-gauge direction is a useful Ward-identity test.
Preparation: Source Ward identities and contact terms. We keep fixed rather than integrate over it. Lorentzian quantities use ; the finite Euclidean example below uses .
Complete the background coupling
With , take
Writing and gives
Thus the current inserted by a background derivative is itself background dependent. The simultaneous transformations and leave the matter action invariant. Keeping only would preserve this only to the first relevant order, then spoil the second derivative.
Normalize by the fixed zero-background integral, not separately by at each background. Assume a common symmetry-preserving regulator and invariant boundary prescription. Direct differentiation of the normalized expectation yields
Here means the derivative-field product prescribed by differentiating the path integral. It is not assumed equal to canonical ordering of every time derivative; the scalar ordering contact illustrates the difference. At ,
The second term is often called a seagull contact. Both terms require the same regulator and, when divergent, mutually consistent local subtractions. Normal ordering the second term away while retaining an unsubtracted bubble does not define that same response. Bilal's §3.1, footnote3, explicitly distinguishes this scalar complication from linearly coupled fermion currents.
Background invariance constrains the response
With no charged scalar sources, invariance of gives
One further derivative implies
This is transversality of the complete response, including contacts. With charged sources present its right side is instead obtained by differentiating the charged-source identity on the preceding pages.
For comparison, a matrix background transforms infinitesimally as . Pairing its matrix current with under a trace and integrating by parts gives
This is background covariance, not a gauge-fixed non-Abelian Slavnov–Taylor derivation. An anomaly or noninvariant boundary data would modify the premise.
Making dynamical is an additional step: one supplies its action and integrates over gauge-equivalence classes with an appropriate quantization prescription. In the present calculation there is no photon propagator or integration over . Also, the coupling current here is distinct from a current defined by the alternative external-source term ; conventions §6.4 fixes that translation.
See the bubble cancel the contact
A Euclidean calculation makes the Gaussian determinant transparent. Define
For the weight , the second derivative of is the connected correlation of two action derivatives minus the mean second action derivative. Expanding at gives
All products and integrals use one prescription. Contracting with uses . If that prescription permits translation of the loop variable, the bubble becomes
In the second term set equal to the new integration variable. The displayed result cancels the contact exactly. A hard cutoff on a fixed momentum ball changes its boundary under this shift; dropping that change is not a valid proof of transversality.
In one Euclidean dimension both integrals converge ordinarily. For any real the bubble is and the contact is . Direct quadrature at confirms cancellation within for . This is a complete convergent example; it is not a four-dimensional renormalized loop evaluation.
An exact finite background
A circle with sites supplies a regulator that preserves local phases exactly. Set the link spacing and charge to one for this finite model, and use
with periodic indices and . If , then
The complex Gaussian integral is proportional to , so up to a fixed constant. Put , , and . Ordinary matrix differentiation gives the two terms
Let denote the link differences. Gauge invariance requires . For , and the nonuniform phases specified in the companion program, a chosen direction gives
The maximum entry of is . Independently differencing the determinant at steps gives maximum Hessian errors : the expected quadratic convergence.
Not every background is removable. The loop phase is invariant modulo . Moving the phases to a uniform link, the eigenvalues are
Their product determines the response plotted below. A pure-gauge change leaves fixed; changing can change .
Exact Gaussian response on a six-site circle with unit link spacing: for (solid) and (dashed), computed from the finite matrix eigenvalues. Local phase changes preserve , while its -periodic variation changes the determinant. No continuum extrapolation is used.
Summary
A background derivative inserts the complete coupling current. Differentiating again also differentiates that current, producing a necessary contact. The continuum contraction and the finite Gaussian determinant show how the contact restores the Ward identity; neither background covariance nor a time-ordered response makes the probe a dynamical or retarded field.
Exercises
- Add to the exponent of the finite Gaussian integral. Show how the source must transform and verify the source-dependent generating function.
Solution
Completing the square gives plus a fixed constant. Under and , the inverse becomes , and both terms are invariant. Holding fixed would describe a different physical source and would not imply a vanishing background divergence. Differentiating this simultaneous invariance gives the finite counterpart of the charged-source Ward identity.
- Put . Derive and use it to check the Hessian.
Solution
Let and . Each eigenvalue factors as . The roots of unity give
Multiplying produces , as claimed. Write . Since every changes by the same amount,
for every pair . Thus the Hessian annihilates all link variations with zero sum, including . This independent formula agrees with the trace expression within in the retained example.
References
- Bilal, A. Lectures on Anomalies (2008), arXiv:0802.0634, §3.1 Eq.(3.3) and footnote3; §3.2 for the non-chiral regulator qualification.
- QFT.org conventions §§5.1, 5.4 and 6.4, for Lorentzian/Euclidean source signs and charged-matter coupling.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.