Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Edge Modes and Gluing Gauge Regions

    Cutting a gauge system creates two copies of a boundary, but it must not create two independent electric fluxes in the reassembled system. Boundary frame variables give one way to describe the pieces before imposing their matching constraint. We will construct that extension and then glue two radial Maxwell regions back into the original shell.

    Preparation: Boundary generators and open Wilson lines. All fluxes use the outward normal of the region they belong to. The kinetic normalization is one, and Ω=∫δAi∧δEi\Omega=\int\delta A_i\wedge\delta E_i.

    A frame can make a regional gauge action null

    Let RR be a spatial region with boundary SS. On the Gauss constraint surface, an ordinary gauge transformation has

    ΩR(Rα,δ)=∮SαδEn.\Omega_R(R_\alpha,\delta)=\oint_S\alpha\delta E_n.

    If boundary flux can vary, transformations with nonzero boundary values are generally not null. One may retain them as physical boundary symmetries, as in the shell. An alternative description introduces a boundary frame φ\varphi and extends the two-form by

    ΩRext=ΩR−∮Sδφ∧δe,e=En∣S.\Omega_R^{\rm ext} =\Omega_R-\oint_S\delta\varphi\wedge\delta e, \qquad e=E_n|_S.

    The equality e=Ene=E_n can either be built into this expression or imposed as a matching constraint after introducing an independent boundary momentum. The frame transforms as

    Rαφ=α∣S,Rαe=0.R_\alpha\varphi=\alpha|_S, \qquad R_\alpha e=0.

    Its contribution is −∮αδe-\oint\alpha\delta e, exactly canceling the bulk contraction. Thus the simultaneous bulk and frame gauge action is null on the constraint surface, including at the boundary. This is a different, enlarged description of the regional data; it is not a proof that the old nonzero charge was absent.

    There remains an independent frame transformation

    Δβφ=−β,ΔβA=ΔβE=0.\Delta_\beta\varphi=-\beta, \qquad \Delta_\beta A=\Delta_\beta E=0.

    For field-independent β\beta,

    ιΔβΩRext=δ∮Sβe.\iota_{\Delta_\beta}\Omega_R^{\rm ext} =\delta\oint_S\beta e.

    The electric flux is now the generator of the relative frame symmetry. The null gauge transformation and the physical frame shift are distinct vectors. Donnelly and Freidel, §§2.4–2.5, develops this separation and the corresponding gluing construction.

    Dress an endpoint relative to the frame

    Use the site's convention D=∂−iqAD=\partial-iqA, ψ↦eiqαψ\psi\mapsto e^{iq\alpha}\psi. A transporter from an interior point xx to a boundary point bb obeys

    U(b,x)=exp⁡(iq∫xbA),U(b,x)↦eiqα(b)U(b,x)e−iqα(x).U(b,x)=\exp\left(iq\int_x^b A\right), \qquad U(b,x)\mapsto e^{iq\alpha(b)}U(b,x)e^{-iq\alpha(x)}.

    The frame-dressed endpoint observable is

    Ψb(x)=e−iqφ(b)U(b,x)ψ(x).\Psi_b(x)=e^{-iq\varphi(b)}U(b,x)\psi(x).

    All phases cancel under the simultaneous gauge action. Under the independent frame shift, however,

    ΔβΨb=iqβ(b)Ψb.\Delta_\beta\Psi_b=iq\beta(b)\Psi_b.

    It is gauge invariant and carries a surface-frame charge. Gauge invariance therefore does not mean insensitivity to every boundary symmetry.

    These formulas describe classical variables and regulated quantum expressions. They do not by themselves construct a pointlike charged Hilbert-space operator: the ultraviolet and long-range dressing questions in charged dressings still apply. Nor does adjoining φ\varphi supply a propagating boundary particle. Propagation requires a physical boundary Hamiltonian and boundary conditions, as supplied explicitly in the Chern–Simons example.

    Cut the shell into two radial regions

    Cut Rin<r<RoutR_{\rm in}<r<R_{\rm out} at RmR_m. Let LL denote the inner region and RR the outer one. Their radial variables are

    aL=∫RinRmAr dr,ΦL=4πr2Erin L,aR=∫RmRoutAr dr,ΦR=4πr2Erin R.\begin{aligned} a_L&=\int_{R_{\rm in}}^{R_m}A_r\,\mathrm dr, &\Phi_L&=4\pi r^2E_r\quad\text{in }L,\\ a_R&=\int_{R_m}^{R_{\rm out}}A_r\,\mathrm dr, &\Phi_R&=4\pi r^2E_r\quad\text{in }R. \end{aligned}

    Before gluing, their product phase space has

    ΩL×R=δaL∧δΦL+δaR∧δΦR.\Omega_{L\times R} =\delta a_L\wedge\delta\Phi_L +\delta a_R\wedge\delta\Phi_R.

    This is a kinematic construction on a time slice; the artificial cut is not assigned a physical material wall or an independently fixed potential. A gauge parameter equal to cc at the cut and zero at the two physical walls acts as

    δcaL=c,δcaR=−c.\delta_c a_L=c,\qquad \delta_c a_R=-c.

    It has generator c(ΦL−ΦR)c(\Phi_L-\Phi_R). The signs have a geometric meaning: the outward interface flux of LL is eL=ΦLe_L=\Phi_L, while that of RR is eR=−ΦRe_R=-\Phi_R. In the absence of a charged sheet, Gauss matching is

    μ=eL+eR=ΦL−ΦR=0.\mu=e_L+e_R=\Phi_L-\Phi_R=0.

    The artificial-interface transformation becomes null only after this constraint is imposed and its tangent variations respected.

    Restrict, then quotient

    Pull back the product form to ΦL=ΦR=Φ\Phi_L=\Phi_R=\Phi:

    ΩL×R∣μ=0=δ(aL+aR)∧δΦ.\left.\Omega_{L\times R}\right|_{\mu=0} =\delta(a_L+a_R)\wedge\delta\Phi.

    Its kernel consists of the relative shifts (δaL,δaR,δΦ)=(c,−c,0)(\delta a_L,\delta a_R,\delta\Phi)=(c,-c,0). Quotienting that direction leaves

    a=aL+aR,Ωglued=δa∧δΦ,a=a_L+a_R, \qquad \Omega_{\rm glued}=\delta a\wedge\delta\Phi,

    precisely the uncut shell. This is symplectic reduction: restriction to the moment-map constraint is followed by identifying its gauge orbit. Doing only one step leaves either mismatched flux or an unphysical null coordinate.

    The Wilson factors agree as well:

    UL=eiqaL,UR=eiqaR,Utotal=URUL=eiqa.U_L=e^{iqa_L},\qquad U_R=e^{iqa_R}, \qquad U_{\rm total}=U_RU_L=e^{iqa}.

    The cut phases are opposite and cancel. There is no surviving extra interface observable in this radial model.

    For general Maxwell fields, matching normal electric flux is necessary but insufficient. The tangential connection must match up to the chosen boundary frames, and the remaining field data must satisfy the desired regularity and dynamics across the cut. The radial sector makes this extra condition automatic because its tangential connection vanishes. A real charged sheet would instead change the flux constraint and require its own degrees of freedom.

    A compact quantum regulator illustrates the projection

    A finite compact-U(1)U(1) link model has integer electric-flux labels. In a product basis ∣m⟩L⊗∣n⟩R|m\rangle_L\otimes|n\rangle_R, the interface transformation acts by eiα(m−n)e^{i\alpha(m-n)}. Averaging over the compact group gives

    ∫02πdα2πeiα(m−n)=δmn.\int_0^{2\pi}\frac{\mathrm d\alpha}{2\pi} e^{i\alpha(m-n)}=\delta_{mn}.

    Only matched fluxes survive. Choices of regional observable algebra, boundary conditions and ultraviolet regulator still matter.

    Summary

    Boundary frames can move the electric-flux generator from a nonnull bulk gauge action to an independent frame symmetry. Gluing then matches the two outward fluxes and quotients the artificial interface action. The explicit shell reduction recovers the original canonical pair and Wilson line, without adding propagating matter at the cut.

    Exercises

    1. Glue three concentric radial regions. Find the two constraints and show that exactly one canonical pair remains.
    Solution

    Start with Ω=∑j=13δaj∧δΦj\Omega=\sum_{j=1}^3\delta a_j\wedge\delta\Phi_j. The two constraints are Φ1−Φ2=0\Phi_1-\Phi_2=0 and Φ2−Φ3=0\Phi_2-\Phi_3=0. On their common surface, all fluxes equal Φ\Phi and

    Ω=δ(a1+a2+a3)∧δΦ.\Omega=\delta(a_1+a_2+a_3)\wedge\delta\Phi.

    The two interface directions are (1,−1,0)(1,-1,0) and (0,1,−1)(0,1,-1) in the aja_j coordinates. Their quotient leaves a=a1+a2+a3a=a_1+a_2+a_3 and Φ\Phi. The product of the three transporter factors is eiqae^{iqa}, independently of the order in which the two reductions are performed.

    1. In the compact link model, impose a fixed interface charge s∈Zs\in\mathbb Z so that the matching equation is m−n=sm-n=s. Construct the projector and identify the role of a charged interface state.
    Solution

    The projector is

    Ps=∫02πdα2πeiα(m−n−s)=δm−n,s.P_s=\int_0^{2\pi}\frac{\mathrm d\alpha}{2\pi} e^{i\alpha(m-n-s)}=\delta_{m-n,s}.

    The factor e−iαse^{-i\alpha s} is the transformation of the interface state needed to cancel the two regional phases in these orientation conventions. Omitting that state and still allowing m≠nm\ne n would violate the original neutral gluing constraint. The fixed integer ss labels this regulator's interface representation; its relation to a physical source-charge sign follows the declared orientation and coupling, rather than an automatic identification with the matter label qq.

    References

    • William Donnelly and Laurent Freidel, Local subsystems in gauge theory and gravity, arXiv:1601.04744v2 (2016), §§2.4–2.5, Eqs.(51)–(62): boundary frames, surface symmetries and gluing by reduction.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.