- Home
- Library
- Thermal and Nonequilibrium Field Theory
- Superfluid, Magnetic, and Anomalous Transport
- Anomaly-Induced Transport
Anomaly-Induced Transport
A magnetic field can carry a current even when there is no electric field to dissipate energy. The identity of that current matters. In a massless Dirac gas at ordinary vector chemical potential, right-handed and left-handed particles travel oppositely along the field: their electric currents cancel, while their axial currents add.
We derive this chiral separation current from the lowest Landau levels, check its coefficient by a finite-temperature integral, and show how the same magnetic currents fit the anomaly and entropy equations. The worked equilibrium response has zero axial chemical potential and no equilibrium electric chiral-magnetic current.
Preparation: The chiral anomaly fixes the spectral-flow sign, and anomalous current definitions distinguishes consistent and covariant insertions. Local equilibrium supplies the first law and fluid conservation equations.
Fix the current before calculating its coefficient
Use a single massless Dirac fermion, with physical electric charge , a prescribed electromagnetic field, and vector chemical potential conjugate to the unit number . Define
The physical charge convention is : it is the site's representation parameter . Thus , and would be the Maxwell-source current if the field were dynamical. We use , , and .
Choose a regulator preserving the vector gauge symmetry. Equivalently, when introducing both vector and axial sources, fix the Bardeen counterterm so that the vector Ward identity is preserved. The resulting identities at zero axial background source are
This is the vector-preserving Dirac axial anomaly. It is not the consistent cubic gauge anomaly of one isolated Weyl field. A consistent current is a derivative of one regulated generating functional, while a covariant current includes the local Bardeen–Zumino improvement needed for covariant transformation. Source differentiation and the improvement must be done before setting an axial source to zero. In this vector-preserving prescription, the axial Bardeen–Zumino difference is proportional to the axial source times its field strength, so it vanishes when that source is zero: the axial current used here agrees with the consistent source insertion. See Landsteiner, §2.4 Eqs. (36a)–(36b), and §4 Eqs. (62)–(63). No factor-of-three replacement by a single-Weyl consistent anomaly is appropriate.
The distinction becomes consequential if an axial background potential is retained or an electric current is inferred from a global equilibrium functional. The normal-ordered bulk occupation currents used below do not, by themselves, specify all boundary and source-contact contributions in that different experiment.
Lowest Landau levels separate the two chiralities
Take a uniform and initially . The kinetic momentum is , so
The transverse ground state has spin , cancelling its orbital zero-point energy. The right Weyl Hamiltonian is and the left one is . Their lowest levels are therefore
For negative , spin and propagation directions reverse while the degeneracy is . Higher Landau levels come in paired spin/longitudinal branches; their contributions to the axial current cancel. This cancellation, including the finite-mass case, is exhibited in Metlitski–Zhitnitsky, §II.C, Eqs. (18)–(37).
On the lowest level, . After subtracting the vacuum, particles and antiparticles contribute the difference of Fermi functions. The two signs of longitudinal momentum give
There is no extra factor in : it is the unit axial current. The magnetic degeneracy already supplies the displayed charge factor. Evaluate the integrals separately:
and use . The result is
It is independent of for this free massless problem, including antiparticles. It changes sign with , or . At , the particle and antiparticle contributions cancel. Keeping only the particle term would incorrectly leave a contribution at zero chemical potential.
The coefficient agrees with Metlitski–Zhitnitsky, Eq. (38). Their convention is the same physical-charge convention chosen here. The Landau-level derivation is exact for the stated free gas in a prescribed uniform magnetic field. In the weak-field hydrodynamic expansion this supplies the term linear in .
A hydrostatic Ward-identity check
Now let a static electric potential vary slowly along a constant . In a region in electrochemical equilibrium at constant temperature,
The matter pressure gradient then balances the electric force: . Evaluate the local magnetic axial current:
This is precisely the axial Ward identity in a stationary state. Local anomaly production is balanced by a divergence of axial current, rather than by a changing axial density. Over a finite segment, the difference of the two endpoint axial currents equals the integrated anomaly. For a periodic potential the net integrated anomaly vanishes, as it must. This is a gradient expansion about local equilibrium; arbitrarily sharp electrostatic structures are outside it.
The example also explains why “anomalous” does not mean that the electric charge leaks out of the system. The vector Ward identity stays exact. The axial charge has an additional local source, and its flux compensates that source in this equilibrium configuration.
Why the entropy current needs an additional term
A naive entropy argument can mistakenly prohibit anomaly-induced transport. The problem is the assumption that the canonical entropy current contains every reversible contribution. We can check its repair explicitly in a restricted magnetic sector, without deriving the complete vortical constitutive theory.
Introduce local chiral occupation parameters and at a common . Here is a local population imbalance, not a prescribed axial gauge potential. With chirality-changing processes or , it is not an exactly conserved equilibrium chemical potential; use it only on time scales for which a local description of the imbalance is justified.
For one chiral lowest-level branch, the excess number integral is . Its energy integral is
For instance, differentiating with respect to gives the number integral, while its value at zero chemical potential fixes the integration constant. Each chiral branch has degeneracy and longitudinal density of states . Subtracting the left-moving energy flux from the right-moving one cancels the two terms. Define . The magnetic bulk contributions are
These are written in the occupation, or thermodynamic, rest frame. It is not the Landau frame when . They specify local reversible bulk contributions for the prepared populations, not a conclusion about a globally equilibrated electric circuit. In particular, the equilibrium calculation above has and zero vector and energy currents.
Let be the densities conjugate to . To isolate the magnetic part of the entropy identity, work in a local rest-frame sector with fixed , no velocity gradients, and gradients only along . The relevant equations are
Using gives
Both cancellations are necessary. The gradient terms cancel by the product rule, and electric work cancels the chemical energy cost of axial production. Omitting the anomalous energy current would leave indefinite-sign gradient terms. Omitting the anomaly would leave indefinite-sign electric work.
The canonical magnetic entropy flux would instead be
It needs the improvement
This result also follows microscopically: the entropy integral of a massless chiral branch is , independent of its chemical potential, so equal-temperature right- and left-moving entropy fluxes cancel. The companion verifies both energy and entropy integrals numerically.
The calculation is a local adiabaticity check for the magnetic sector, not a solution of arbitrary fluid profiles: momentum balance, acceleration and vorticity require the remaining constitutive terms. The general entropy-current construction includes magnetic and vortical improvements, as derived in Son–Surówka, Eqs. (8)–(18). Their mostly-plus tensor formulas must be translated with the field, chirality and current definitions; the three-vector balance above fixes our signs directly. Entropy constraints alone also do not determine every possible thermal/vortical coefficient without further microscopic or anomaly information.
A reproducible response calculation and its limits
Take , and . The massless result is at every positive temperature. The companion examples/thermal/hydrodynamics/extended-fluids/ compares adaptive integration with finite-length, antiperiodic longitudinal momentum sums, increases the box size, and checks reversal of . At , the number-integral error decreases from at length to at and below at . It also checks the magnetic energy/entropy balance and a sinusoidal hydrostatic potential with a refined spatial derivative.
A fermion mass provides a useful counterexample to unrestricted temperature independence. The same lowest-level calculation gives
For , this generally depends on . The Ward identity also acquires ; one cannot retain only the massless anomaly and reuse the massless hydrostatic cancellation. Axial relaxation, boundaries, interactions and dynamical electromagnetic backreaction require separate calculations. An anomaly coefficient is protected information about a Ward identity; it does not automatically protect every transport coefficient in every thermodynamic regime.
Summary
Lowest Landau levels give a free massless Dirac gas the axial magnetic response while its equilibrium electric current vanishes at . Electrochemical equilibrium makes the spatial divergence of this axial current reproduce the anomaly. In a local magnetic transport sector, the associated energy current and an entropy-current improvement cancel the apparently indefinite-sign entropy production.
Exercises
1. A massive threshold. Evaluate the axial magnetic current at for arbitrary real and . Determine how it approaches the massless result.
Solution
For , only particles with are occupied. For , the corresponding antiparticle contribution has the opposite sign. For , there is no finite-density occupation. Therefore
The value at threshold is zero independently of the convention for . At fixed nonzero and small , . At fixed mass, the current instead turns on with a square-root threshold. These orders of limits differ near .
2. Change to the Landau frame. Given the local magnetic currents with a small , find the first-order velocity change that removes the energy current. What happens to the axial response at ?
Solution
At first derivative order, the velocity shift moves the energy flux into convection, where . The nonconvective currents become
The total physical currents are unchanged because the new convective contributions add back and . At in the parity-symmetric Dirac gas, and the energy current vanishes, so the axial magnetic coefficient is unchanged. At general imbalance, quoting a coefficient without its fluid frame would confuse a nonconvective coefficient with the full current.
References
- K. Landsteiner, Notes on Anomaly Induced Transport, arXiv:1610.04413v4, §2.4 Eqs. (36a)–(36b) and §4 Eqs. (62)–(63) in the HTML edition: current improvements in the vector-preserving prescription and their absence for the chiral separation response. The PDF numbers these equations (2.36a)–(2.36b), (4.62)–(4.63).
- M. A. Metlitski and A. R. Zhitnitsky, Anomalous Axion Interactions and Topological Currents in Dense Matter, arXiv:hep-ph/0505072v1, §II.C, printed pp. 4–7, Eqs. (14)–(40): background Dirac problem, zero-mode current, finite-temperature integral and massive limit.
- D. T. Son and P. Surówka, Hydrodynamics with Triangle Anomalies, arXiv:0906.5044v2, printed pp. 2–3, Eqs. (5)–(18): anomalous Ward identities and the required entropy-current additions. The magnetic occupation calculation and restricted entropy check above state their current and frame conventions explicitly.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.