    Quantum Noise and Fluctuation Relations

    A detector can distinguish a bath that absorbs energy from one that emits it. A symmetrized noise spectrum adds these two possibilities and loses that distinction. We derive the two transition rates of a quantum detector, calculate the effect of finite observation time, and construct a stationary pumped bath whose apparent temperature depends strongly on the detector gap.

    Preparation: Thermal spectral representations and influence functionals supply the Wightman, response and symmetric kernels. Dynamical KMS symmetry explains the equilibrium relation; here we connect it to a measured transition.

    What a noise spectrum orders

    Let B=B†B=B^\dagger be a bath operator with its stationary mean removed. Define

    W>(t)=⟨B(t)B(0)⟩,W<(t)=⟨B(0)B(t)⟩,W>(ω)=∫dt eiωtW>(t).W^>(t)=\langle B(t)B(0)\rangle,\qquad W^<(t)=\langle B(0)B(t)\rangle,\qquad W^>(\omega)=\int dt\,e^{i\omega t}W^>(t).

    Stationarity gives W<(ω)=W>(−ω)W^<(\omega)=W^>(-\omega). In an energy-diagonal state with probabilities pmp_m,

    W>(ω)=2π∑m,npm∣Bnm∣2δ(ω−(En−Em)).W^>(\omega)=2\pi\sum_{m,n}p_m|B_{nm}|^2\delta\bigl(\omega-(E_n-E_m)\bigr).

    It is a positive measure. Positive frequency means the bath absorbs energy; negative frequency means the bath emits it. These labels refer to the bath, so the detector changes its energy in the opposite direction.

    The commutator and symmetric spectra are

    ρB(ω)=W>(ω)−W>(−ω),NB(ω)=W>(ω)+W>(−ω)2.\rho_B(\omega)=W^>(\omega)-W^>(-\omega),\qquad N_B(\omega)=\frac{W^>(\omega)+W^>(-\omega)}2.

    Consequently NB≥∣ρB∣/2N_B\geq|\rho_B|/2 as scalar spectral measures. With the site's retarded convention, ρB=−2Im⁡GR,B=2Im⁡χB\rho_B=-2\operatorname{Im}G_{R,B}=2\operatorname{Im}\chi_B. Positivity gives this noise inequality even outside equilibrium. Thermal equilibrium adds pn/pm=e−β(En−Em)p_n/p_m=e^{-\beta(E_n-E_m)} and hence

    W>(−ω)=e−βωW>(ω),NB(ω)=12coth⁡ ⁣(βω2)ρB(ω).W^>(-\omega)=e^{-\beta\omega}W^>(\omega),\qquad N_B(\omega)=\frac12\coth\!\left(\frac{\beta\omega}{2}\right)\rho_B(\omega).

    This relation assumes physical Hamiltonian time evolution and zero chemical potential. A stationary pumped state need not satisfy it.

    A two-level detector fixes the frequency sign

    Take Hd=Ωσz/2H_d=\Omega\sigma_z/2 with Ω>0\Omega>0, and couple weakly through Hint=gds(t)σxBH_{\rm int}=g_d s(t)\sigma_x B. The real switching function s(t)s(t) specifies when the detector is active. In the interaction picture, excitation carries eiΩte^{i\Omega t}. Squaring its first-order amplitude and summing final bath states yields

    P↑=gd2∫dω2π W>(ω)∣s~(Ω+ω)∣2+O(gd4),s~(ν)=∫dt eiνts(t).P_\uparrow=g_d^2\int\frac{d\omega}{2\pi}\,W^>(\omega)|\widetilde s(\Omega+\omega)|^2+O(g_d^4),\qquad \widetilde s(\nu)=\int dt\,e^{i\nu t}s(t).

    For example, a bath transition m→nm\to n contributes a phase ei(Ω+En−Em)te^{i(\Omega+E_n-E_m)t}; a long observation selects En−Em=−ΩE_n-E_m=-\Omega. The analogous decay probability selects +Ω+\Omega. Dividing by a long observation time gives

    Γ↑=gd2W>(−Ω),Γ↓=gd2W>(+Ω).\Gamma_\uparrow=g_d^2W^>(-\Omega),\qquad \Gamma_\downarrow=g_d^2W^>(+\Omega).

    These are the conventions of Clerk et al., § II.B, Eq. (2.6), and Appendix B.1 (PDF), with ℏ=1\hbar=1 and their A=gdA=g_d. The detector's population equation is

    p˙e=Γ↑(1−pe)−Γ↓pe,pess=Γ↑Γ↑+Γ↓.\dot p_e=\Gamma_\uparrow(1-p_e)-\Gamma_\downarrow p_e,\qquad p_e^{\rm ss}=\frac{\Gamma_\uparrow}{\Gamma_\uparrow+\Gamma_\downarrow}.

    For a thermal bath the ratio is e−βΩe^{-\beta\Omega} and pess=1/(1+eβΩ)p_e^{\rm ss}=1/(1+e^{\beta\Omega}). The long-time rate equation resums repeated weak transitions. The displayed finite-window perturbative probability instead requires P↑≪1P_\uparrow\ll1; it cannot be extrapolated until it exceeds unity.

    At zero temperature an equilibrium bath has Γ↑=0\Gamma_\uparrow=0 but can have Γ↓>0\Gamma_\downarrow>0. Its nonzero symmetric vacuum noise therefore does not represent equal probabilities of absorption and emission.

    A continuous bath with a controlled observation window

    For a harmonic bath with BB linear in oscillator coordinates, define a positive spectral density I(ν)I(\nu) for ν>0\nu>0. Using the normalization in non-Markovian dynamics,

    W>(ν)=2I(ν)[n(ν)+1],W>(−ν)=2I(ν)n(ν),Im⁡χB(ν)=I(ν).W^>(\nu)=2I(\nu)[n(\nu)+1],\qquad W^>(-\nu)=2I(\nu)n(\nu),\qquad \operatorname{Im}\chi_B(\nu)=I(\nu).

    For a thermal bath n(ν)=1/(eν/T−1)n(\nu)=1/(e^{\nu/T}-1). We use the smooth continuum spectrum

    I(ν)=ηνΛ4(ν2+Λ2)2,T=0.8,η=0.3,Λ=4.I(\nu)=\frac{\eta\nu\Lambda^4}{(\nu^2+\Lambda^2)^2},\qquad T=0.8,\quad \eta=0.3,\quad \Lambda=4.

    The high-frequency decay makes the equal-time symmetric noise finite. At small frequency NB(0)=2ηTN_B(0)=2\eta T. These statements concern the continuum bath itself, before approximating its effect on another system.

    For Gaussian switching s(t)=e−t2/(2τ2)s(t)=e^{-t^2/(2\tau^2)}, the squared window is 2πτ2e−τ2ν22\pi\tau^2e^{-\tau^2\nu^2} and ∫s2dt=πτ\int s^2dt=\sqrt\pi\tau. Define the normalized finite-window spectrum

    W‾τ(c)=τπ∫dω e−τ2(ω−c)2W>(ω).\overline W_\tau(c)=\frac{\tau}{\sqrt\pi}\int d\omega\,e^{-\tau^2(\omega-c)^2}W^>(\omega).

    Then P↑/(gd2πτ)=W‾τ(−Ω)P_\uparrow/(g_d^2\sqrt\pi\tau)=\overline W_\tau(-\Omega), and similarly for decay. The normalized ratio tends to e−Ω/Te^{-\Omega/T} as the frequency window narrows. At finite τ\tau, KMS holds inside the integral, but its Boltzmann factor varies across that integral; it cannot be pulled out as e−Ω/Te^{-\Omega/T}.

    For Ω=1.7\Omega=1.7, direct quadrature gives:

    Window duration τ\tauW‾τ(−Ω)/W‾τ(+Ω)\overline W_\tau(-\Omega)/\overline W_\tau(+\Omega)Relative difference from e−Ω/Te^{-\Omega/T}
    20.129987428.84×10−28.84\times10^{-2}
    40.122074632.21×10−22.21\times10^{-2}
    80.120093445.53×10−35.53\times10^{-3}
    160.119598091.38×10−31.38\times10^{-3}

    The approximately fourfold improvement when τ\tau doubles is the expected even-window expansion. A finite-time ratio that differs from a Boltzmann factor is not by itself evidence of a nonthermal bath.

    A pumped bath with the same response

    Now maintain a larger occupation around one band:

    npump(ν)=1eν/T−1+2exp⁡ ⁣[−(ν−1.7)22(0.25)2].n_{\rm pump}(\nu)=\frac{1}{e^{\nu/T}-1}+2\exp\!\left[-\frac{(\nu-1.7)^2}{2(0.25)^2}\right].

    This is a positive stationary Gaussian distribution for independent harmonic modes. A physical realization maintains each mode with incoherent loss and pump whose ratio is npump/(npump+1)n_{\rm pump}/(n_{\rm pump}+1), then takes the weak-linewidth continuum limit over the observation band. The pumps supply energy and do not constitute a single equilibrium reservoir. No phase-coherent drive or rotating frame is being assumed here; driven steady states treats a different, coherent parametric drive.

    Changing the occupations leaves ρB(ν)=2I(ν)\rho_B(\nu)=2I(\nu) unchanged, while increasing the symmetric noise. In the resolved-frequency detector limit,

    Teff(Ω)=Ωlog⁡ ⁣[W>(Ω)/W>(−Ω)]=Ωlog⁡[(npump(Ω)+1)/npump(Ω)].T_{\rm eff}(\Omega)=\frac{\Omega}{\log\!\left[W^>(\Omega)/W^>(-\Omega)\right]}=\frac{\Omega}{\log[(n_{\rm pump}(\Omega)+1)/n_{\rm pump}(\Omega)]}.

    At gaps 0.60.6, 1.71.7 and 2.82.8, the inferred temperatures are 0.800080.80008, 4.426304.42630 and 0.800890.80089. The pumped gap gives Γ↑/gd2=1.56279718\Gamma_\uparrow/g_d^2=1.56279718 and Γ↓/gd2=2.29456991\Gamma_\downarrow/g_d^2=2.29456991. Hence pess=0.40514609p_e^{\rm ss}=0.40514609. Without the pump the same detector gives pess=0.10669059p_e^{\rm ss}=0.10669059. A single detector population can be fitted to a temperature; the three-gap comparison rejects one common temperature.

    The specified nonnegative bosonic occupations always give greater absorption than emission. They do not model an inverted reservoir or negative damping. More general active baths require a separate operator model and stability analysis.

    The companion in examples/thermal/open-systems/noise-probe/ evaluates both finite-window probabilities and resolves the detector population equation numerically. The latter agrees with its exponential solution within 8×10−138\times10^{-13}. The frequency-resolved bath formulas used here are not the finite-linewidth Lorentzian regression spectra of a phenomenological Lindblad oscillator: thermal stationary oscillator populations alone do not enforce exact off-resonant KMS.

    When classical noise is enough

    A real stationary classical random field has an even power spectrum. Used as an external Hamiltonian perturbation, it drives upward and downward detector transitions equally. It can reproduce NBN_B, but cannot simultaneously reproduce the quantum absorption–emission asymmetry encoded by ρB\rho_B.

    At ∣ω∣≪T|\omega|\ll T, thermal KMS gives NB≃TρB/ωN_B\simeq T\rho_B/\omega. If the response is also Ohmic, Im⁡χB≃ηω\operatorname{Im}\chi_B\simeq\eta\omega, a classical Langevin description with noise 2ηT2\eta T and the separately matched friction is appropriate. Its frequency range, bath preparation and neglected memory must be stated. Classical noise alone does not predict the zero-temperature detector rates.

    Summary

    Detector excitation measures negative-frequency bath noise and detector decay measures positive-frequency noise. Their sum determines symmetric fluctuations; their difference determines dissipation. Thermal KMS fixes their ratio only in equilibrium and at resolved frequency. Finite observation windows and externally maintained occupations provide two distinct, calculable reasons for a measured ratio to differ from a single Boltzmann factor.

    Exercises

    1. Extracting damping without assuming a temperature

    An oscillator detector with coordinate x=(a+a†)/2mdΩx=(a+a^\dagger)/\sqrt{2m_d\Omega} couples through gdxBg_d xB. Derive its occupation equation, and determine when a stationary occupation exists.

    Solution

    The matrix element of xx supplies n/(2mdΩ)n/(2m_d\Omega) for downward transitions and (n+1)/(2mdΩ)(n+1)/(2m_d\Omega) for upward transitions. Summing the birth–death equation gives

    ∂t⟨n⟩=−γ⟨n⟩+gd2W>(−Ω)2mdΩ,γ=gd2[W>(Ω)−W>(−Ω)]2mdΩ.\partial_t\langle n\rangle=-\gamma\langle n\rangle+\frac{g_d^2W^>(-\Omega)}{2m_d\Omega},\qquad \gamma=\frac{g_d^2[W^>(\Omega)-W^>(-\Omega)]}{2m_d\Omega}.

    For γ>0\gamma>0, the stationary occupation is W>(−Ω)/[W>(Ω)−W>(−Ω)]W^>(-\Omega)/[W^>(\Omega)-W^>(-\Omega)]. In the pumped bath this equals npump(Ω)n_{\rm pump}(\Omega), despite the lack of a common temperature. Equal nonzero rates produce unbounded diffusive heating; greater emission produces exponential growth until nonlinear effects matter. Zero rates leave the occupation unchanged. Symmetric noise alone therefore cannot determine stability.

    2. The leading finite-window bias

    For a smooth thermal W>W^> near ±Ω\pm\Omega, derive the leading correction to the Gaussian-window transition ratio. Use it to explain the convergence table.

    Solution

    The normalized Gaussian has variance 1/(2τ2)1/(2\tau^2), so

    W‾τ(c)=W>(c)+W>′′(c)4τ2+O(τ−4).\overline W_\tau(c)=W^>(c)+\frac{W^{>\prime\prime}(c)}{4\tau^2}+O(\tau^{-4}).

    Let f(Ω)=W>(Ω)f(\Omega)=W^>(\Omega). KMS gives W>(−Ω)=e−βΩf(Ω)W^>(-\Omega)=e^{-\beta\Omega}f(\Omega). Two derivatives with respect to the negative-frequency argument equal two derivatives with respect to Ω\Omega. Consequently,

    W‾τ(−Ω)W‾τ(+Ω)=e−βΩ[1+β2−2βf′(Ω)/f(Ω)4τ2+O(τ−4)].\frac{\overline W_\tau(-\Omega)}{\overline W_\tau(+\Omega)}=e^{-\beta\Omega}\left[1+\frac{\beta^2-2\beta f'(\Omega)/f(\Omega)}{4\tau^2}+O(\tau^{-4})\right].

    The correction depends on the absorption slope and temperature. At fixed gap, doubling τ\tau reduces the leading bias by four. Near a nonsmooth threshold or narrow spectral feature, use the full window integral.

    References