- Home
- Library
- Thermal and Nonequilibrium Field Theory
- Thermal Masses, Pressure, and Lifetimes
- The Scalar Thermal Mass
The Scalar Thermal Mass
A weakly interacting scalar can be massless in vacuum and still have a finite correlation length in a hot state. The first correction comes from a tadpole: fluctuations of the occupied modes change the restoring force experienced by a long-wavelength field. We will derive its coefficient, evaluate it at arbitrary positive mass-to-temperature ratio, and identify the regime in which inserting it perturbatively ceases to work.
Preparation: Thermal Feynman rules and thermal sum-integrals. There is one real scalar with Lorentzian interaction , , zero chemical potential and no condensate. We use a zero-temperature pole mass in the free propagators and the corresponding vacuum mass counterterm; may be an MSbar coupling. Take the thermodynamic limit before the massless limit. This does not assert that a free massless constant mode has a normalizable finite-box Gibbs trace.
The tadpole changes the inverse propagator
Attaching two labeled external fields to a quartic vertex gives contractions, and the other two fields close into a loop. The normalized correlator therefore has
The negative correction to the covariance is a positive correction to its inverse. At this order the self-energy has no external frequency or momentum dependence. The Matsubara sum, or the occupation-number covariance of each harmonic mode, gives
Here and . Pole-mass renormalization fixes through first order, including its finite part. It is fixed at zero temperature. The remaining state-dependent shift is
The integral is ultraviolet finite and positive. It vanishes at zero temperature; it is not an ultraviolet counterterm. In an MSbar mass convention there is also a finite vacuum self-energy, and the physical thermal difference is obtained only after using the same vacuum mass on both sides, as shown in the preceding article.
To this order the Euclidean inverse is . Its constant correction continues to the retarded inverse . Thus a static screening pole and the zero-momentum real-time pole have the same squared-mass shift at this order. This conclusion uses the special local tadpole; it neither computes a damping rate nor proves equality of mass definitions once self-energies depend on frequency and momentum. Our named has physical source response .
Massive particles: an exact thermal integral
For , expand the Bose factor as . Each term is positive, so exchanging sum and momentum integration is justified. The substitution yields
We used and . Therefore
This convergent sum is particularly effective when is not small; direct radial integration is more efficient close to the massless limit. It matches Laine–Vuorinen, §2.2, Eq.(2.77) and footnote 7, printed p.21. The sum is a representation of the one-loop result, not a resummation of interaction diagrams.
The integral and Bessel sum give the following dimensionless values:
In the companion at examples/thermal/thermal-perturbation-theory/scalar-loops/, direct radial quadrature and a 4096-term Bessel sum agree to in these values; the zero-mass row uses the exact limit. At , increasing the sum from 8 to 32 to 128 terms reduces the absolute error from to to . The agreement concerns this one-loop integral, not the size of omitted interaction corrections.
At , the term dominates. The Bessel integral is localized near , or equivalently at momenta . Expanding the energy and measure there, or using the large-argument expansion of , gives
The leading term is times the dilute excitation density. The real scalar has no conserved particle number; this density counts rare massive quanta in the thermal ensemble. The coefficient differs from the correction to the dilute number density because the tadpole carries . Setting that factor to beyond leading order would give the wrong relativistic correction. The power series is asymptotic; the separate exponentially small terms come from Bose exchange cycles .
Keeping the two displayed relativistic corrections gives relative errors of approximately , and at . These were calculated after scaling out the Boltzmann exponential, so the comparison does not rely on an absolute integration tolerance larger than the small density.
High temperature and the static nonanalytic term
At the integral can be evaluated by its exponential series:
The coefficient depends on the interaction convention. In Laine–Vuorinen, §3.3, Eqs.(3.69)–(3.72), the vertex follows from , so their tadpole coefficient is ; here .
The correction at small nonzero cannot be found by a uniform expansion in inside the zero mode. Subtract its massless integrand before taking the continuum limit:
This convergent difference isolates the linear term. Nonzero frequencies have a gap and can be expanded in ; their ultraviolet pole cancels against the vacuum tadpole when forming . Combining them gives
The derivation of the nonzero-mode coefficient is given in thermal sum-integrals; the combined expression agrees with Laine–Vuorinen, §2.3, Eqs.(2.84)–(2.93). There is no subtraction scale left in this thermal integral. The logarithm is of the physical ratio .
The negative linear term does not make the full tadpole negative: the exact positive integral decreases smoothly from as the gap grows. A truncated high-temperature expansion must not be extrapolated into the dilute regime.
When a mass correction becomes a new leading scale
For fixed nonzero vacuum mass, ordinary perturbation theory requires if the mass shift is to be treated as a small correction. In the hot nearly massless regime this condition fails even at weak coupling. The leading static scale instead is
The notation here denotes the leading screened scale, not an exact solution to a gap equation. At hard momenta , inserting costs a relative factor of order . At static soft momenta , the ratio can be order one. Every insertion must then be retained in the denominator. A further convergent static loop measures a different expansion parameter:
Thus screening reorganizes the soft expansion without making it identical to the vacuum loop expansion. For , the first soft tadpole correction is proportional to and is of order , whereas the leading mass squared is of order . This is a power-counting statement; treating a one-loop self-consistency equation as an exact mass prediction would omit other higher-order contributions.
The reorganization is an identity only if the inserted mass is also subtracted from the interactions:
Use screened free propagators from the first term and the compensating quadratic vertex from the second. Omitting that vertex changes the theory and double counts the hard tadpole. The ultraviolet counterterms must also be organized consistently. Ring resummation performs this counting for the pressure, while dimensional reduction separates hard matching from static dynamics. Close enough to a critical point, a small physical screening mass can again make the static expansion strong.
Summary
The one-loop scalar thermal mass follows from the labeled tadpole factor and a finite occupation integral after zero-temperature renormalization. Its high-temperature limit is ; its low-temperature limit is Boltzmann suppressed with a calculable relativistic correction. The induced scale explains why static propagators must be reorganized while hard modes remain perturbative.
Exercises
1. Change the number of components. Replace the scalar by real fields with interaction and a common positive vacuum mass. Derive the one-loop thermal mass matrix in the symmetric phase. Check .
Solution
Four field derivatives of the interaction give the Euclidean vertex
Contract the two internal indices with and include the tadpole symmetry factor . The first tensor contributes and each of the other two contributes . Thus
For this is and . The result assumes unbroken and equal free masses; it is not the mass matrix in a broken background, where longitudinal and transverse propagators differ. A large- limit also requires specifying how scales with .
2. Bound the thermal shift and test its derivative. Prove that for . Differentiate with respect to and explain why an expansion analytic in about zero fails even though itself is finite.
Solution
For fixed , both and decrease when increases. Positivity and comparison with the integrable massless function give the strict bounds. At fixed , differentiation under the convergent integral is permitted and yields
As , the static contribution gives . The derivative diverges although the original integral tends to . Integrating this singular derivative recovers the finite term , nonanalytic in . A Taylor expansion that interchanges the massless limit with this derivative loses the soft region.
References
- M. Laine and A. Vuorinen, Basics of Thermal Field Theory: A Tutorial on Perturbative Computations, arXiv:1701.01554v2, January 2022, §2.2, printed pp.21–22, Eqs.(2.76)–(2.80) and footnote 7; §2.3, pp.23–25, Eqs.(2.82)–(2.95); §3.3, pp.41–42, Eqs.(3.69)–(3.73); §3.4, pp.44–47, Eqs.(3.80)–(3.95). Our quartic coupling is six times theirs; the vacuum mass is a pole mass and the loop measure contains the MSbar scale factor.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.