- Home
- Library
- Thermal and Nonequilibrium Field Theory
- Causal Response, Fluctuations, and Diffusion
- Fluctuation–Dissipation Relations
Fluctuation–Dissipation Relations
A weak force probes how an oscillator responds; an equilibrium measurement records how that oscillator fluctuates without the force. The fluctuation–dissipation relation connects these experiments. Quantum mechanically, the connection contains both thermal fluctuations and zero-point motion, and a static conserved fluctuation requires separate treatment.
Preparation: Thermal KMS and thermal spectral representations. We use a neutral Hermitian observable, physical -time, and the source convention .
Fix the response sign before applying KMS
Let , and define the connected symmetric covariance
First-order interaction-picture evolution gives . Consequently
Here is the site's named retarded correlator, with its definition. The spectral function is the Fourier transform of the full commutator, so
This source-sign package agrees with Kovtun, §§2.1–2.3, Eqs. (2.4)–(2.9). If the measured operator itself depends on , differentiating it adds an instantaneous contact response. Couplings to derivatives of a source can also generate contacts. The oscillator below has a source-independent coupled linearly to , so neither complication occurs.
Thermal fluctuations and absorption
Write the raw Wightman functions as and , without prefactors of . KMS gives , while and . Eliminating the two Wightman functions yields the nonsingular identity
For nonzero transition frequencies it can be inverted:
These are equalities of spectral measures. A delta line is evaluated with its coefficient; it is not a broadened peak. For a finite regulated system, the full answer is , with the squared thermal norm of the centered energy-block projection defined in the preceding article. Multiplication by removes that atom. Dividing by it cannot recover the lost weight. A continuum infrared limit requires its own distributional prescription; it is not enough to multiply an arbitrary singular spectrum by .
At positive frequency, physical-Hilbert-space positivity implies : a passive equilibrium system absorbs energy from a weak drive. At zero temperature, away from zero, so fluctuations persist even in the vacuum. For frequencies in the nonzero sector,
This classical low-frequency form has relative corrections of order . It does not determine the conserved zero atom. The equilibrium and positivity hypotheses matter: stationarity alone gives a spectral representation but does not fix a common temperature-dependent ratio of fluctuation and response weights.
An oscillator, without damping
Take , with and . The Heisenberg solution and commutator are
Thus the response to a positive force is
In particular , by completing the square in . The retarded boundary is ; no damping constant has been introduced.
The oscillator trace gives , and . Hence
The commutator spectrum and absorptive response are
At the positive line, FDT supplies . At the negative line, both and change sign, producing the same positive symmetric weight. Integrating both lines gives . Temperature changes their fluctuation weights while leaving the causal response unchanged, because this commutator is a number fixed by the canonical algebra.
The time-domain relation and its classical limit
The quantum frequency multiplier is not generally a local derivative in time. An exact derivative relation uses the connected Kubo-transformed covariance
Each transition of frequency acquires the factor , with its continuous value one at zero. Therefore in the nonzero sector, together with the same static term. Taking a time derivative removes that term and gives
For the oscillator the imaginary-time integral can be done before the real-time transform:
This is an exact quantum check at any . The classical approximation replaces the symmetric covariance by this Kubo transform: when , and . At low temperature that replacement would lose zero-point fluctuations. For example, the ratio of the exact equal-time variance to its classical value is , which tends to one only in the high-temperature limit.
The companion in examples/thermal/equilibrium/spectra-response/ constructs truncated ladder matrices and thermal traces. At , and , the exact variance is . Increasing the retained number of oscillator levels gives:
| Levels | Absolute error in | Largest error in a Wightman line weight |
|---|---|---|
| below | below |
Line weights here mean coefficients in ; the observable is the composite in the spectral article's second exercise. KMS holds within each finite truncation, but recovering the canonical oscillator moments requires cutoff convergence. Separate imaginary-time quadrature checks . A three-level unitary source calculation verifies the response sign and distinguishes isolated from re-equilibrated susceptibility. All spectra remain weighted atoms.
A conserved fluctuation is not an isolated response
For the same oscillator, take . Since ,
An isolated perturbation changes phases and level energies but not the initial number probabilities. Re-equilibrating with a reservoir at fixed instead replaces by and yields
The nonzero thermodynamic susceptibility is the Euclidean static contribution . It cannot be inferred from the vanishing isolated commutator. This is the simplest instance of the distinction developed in static susceptibilities.
An equilibrium stochastic field gives an explicit version of this distinction. Compare the two Model B limits of a uniform source: the fixed uniform charge cannot respond, whereas a slowly varying mode can equilibrate by a current. If the initial charge is sampled across sectors, its variance contributes a delta function at zero frequency.
Noise of a diffusing density wave
Unlike the uniform conserved charge, a density fluctuation at wave number can relax without changing the total charge. Let with , and use the response of a diffusive mode, . In the classical low-frequency regime, the fluctuation relation gives
This Lorentzian has half-width and integrated weight with measure . Equivalently its time covariance is in the leading stochastic diffusion model. Halving divides the width by four and multiplies the height by four. The area remains fixed. In an underlying medium this is a low-frequency prediction in the hydrodynamic limit. The current-noise derivation obtains the same area by requiring equilibrium variance. Kovtun, §4.1, Eqs. (4.1)–(4.4)
Summary
KMS relates symmetric fluctuations to absorption, with the response sign fixed by the source coupling. The oscillator verifies the quantum relation as an equality of delta-line weights and the time-domain relation through the Kubo transform. The classical derivative formula follows only at low frequencies compared with temperature. Static conserved fluctuations remain additional equilibrium information.
Exercises
1. Energy deposited by a finite pulse. Start in a thermal state with . Apply for and zero otherwise. Find the mean motion and the final energy increase. Recover the same energy from the absorptive spectral lines.
Solution
Convolve the pulse with , or solve with continuous position and velocity. The result is
A linear force displaces the Gaussian state without changing its covariance. After the force is removed, the extra oscillator energy is the energy of this mean motion:
With the source zero at the two endpoints, the work is . Fourier transformation gives
The two spectral atoms give , equal to the expression above. A pulse lasting an integer number of oscillator periods leaves no net displacement; it returns the supplied energy. No irreversible relaxation or finite-width peak is required for this finite-pulse absorption calculation. For , , and , direct integration of the forced equation gives , agreeing with the spectral work integral within .
2. Stationary but not thermal. Let , , and let a stationary density matrix have probabilities . A Hermitian observable has unit matrix elements between levels and , and no others. Determine whether its fluctuation and response spectra obey FDT at a single temperature.
Solution
The positive transition frequencies are and . Their weights are and ; the corresponding weights are and . Detailed balance would require
The first equation implies , which disagrees with . Equivalently the two inferred inverse temperatures are and . The symmetric weights are and , whereas the commutator weights are and , all in units of . They cannot share one multiplier. The state is stationary and its positive-frequency absorption is positive, but neither fact supplies the missing KMS condition.
References
- Kovtun, Pavel. “Lectures on Hydrodynamic Fluctuations in Relativistic Theories” (2012), §§2.1–2.3, Eqs. (2.4)–(2.9), spectral/FDT identities preceding (2.14), and positivity statement (2.15). arXiv:1205.5040v1. His -time convention agrees with physical -time for the neutral observables used here.
- Laine, Mikko, and Aleksi Vuorinen. Basics of Thermal Field Theory: A Tutorial on Perturbative Computations, January 2022 version, §8.1, printed pp.114–120, Eqs. (8.1)–(8.22) and (8.30)–(8.36). arXiv:1701.01554v2. Their spectral function is half ours, and their retarded equals our physical response .
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.