Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Zero-Temperature Onset and the Silver Blaze Property

    Why can changing a chemical potential leave the zero-temperature vacuum unchanged, even though every propagator in a functional integral appears to change? The chemical potential rewards charge, but it must first overcome the energy required to create that charge. We derive the exact threshold from the spectrum, test it in a solvable interacting system, and distinguish an unchanged state from unchanged charged correlation functions.

    Preparation: The ensemble generated by K=H−μQK=H-\mu Q in chemical potentials. Throughout, QQ is a conserved global charge and μ\mu is its chemical potential.

    The first state that can beat the vacuum

    At finite spatial volume VV, suppose [H,Q]=0[H,Q]=0, and let ∣n⟩|n\rangle have energy EnE_n and charge qnq_n. Assume a unique neutral ground state ∣0⟩|0\rangle of HH, with energy E0E_0 and q0=0q_0=0. The grand partition function is

    Z(β,μ)=e−βE0[1+∑n≠0e−β(En−E0−μqn)],β=1/T.Z(\beta,\mu)=e^{-\beta E_0}\left[1+\sum_{n\ne0}e^{-\beta(E_n-E_0-\mu q_n)}\right],\qquad \beta=1/T.

    This expression presupposes a stable grand ensemble and a convergent trace. The vacuum remains the unique ground state of KK precisely while every quantity En−E0−μqnE_n-E_0-\mu q_n is positive. Define the positive- and negative-charge thresholds

    μ+(V)=inf⁡qn>0En−E0qn,μ−(V)=inf⁡qn<0En−E0∣qn∣.\mu_+(V)=\inf_{q_n>0}\frac{E_n-E_0}{q_n},\qquad \mu_-(V)=\inf_{q_n<0}\frac{E_n-E_0}{|q_n|}.

    Then, in the open interval −μ−(V)<μ<μ+(V)-\mu_-(V)<\mu<\mu_+(V), the zero-temperature state is unchanged. The grand potential Ω=−Tlog⁡Z\Omega=-T\log Z tends to E0E_0, and ⟨Q⟩=−∂μΩ\langle Q\rangle=-\partial_\mu\Omega tends to zero. A fixed, source-independent observable has its vacuum expectation value. If the threshold infimum is attained, a charged state becomes degenerate with the vacuum there. If it is not attained, an accumulation of charge sectors or loss of grand-ensemble stability can instead control the endpoint; the open-interval argument alone does not decide its behavior.

    The minimum is over all charge sectors, including bound states and states whose charge grows with volume. The mass of the lightest charge-one particle is therefore an upper bound on the positive onset, not a universal formula for it. Binding can reduce energy per charge, and a bulk phase can set the threshold. In gauge theories, only physical states satisfying the gauge constraints belong in this comparison.

    This spectral explanation is elementary; recovering it from a chemical-potential-dependent functional integral can be difficult. Cohen's original Silver Blaze discussion makes that distinction for finite-isospin QCD. His isospin result uses the absence of an earlier first-order transition; it is not a general solution of the baryon-density problem.

    A charged system with an exact density staircase

    Consider two bosonic occupation numbers n+,n−=0,1,2,…n_+,n_-=0,1,2,\ldots, with

    H=m(n++n−)+u2V(n+2+n−2),Q=n+−n−,m>0,u>0.H=m(n_++n_-)+\frac{u}{2V}(n_+^2+n_-^2),\qquad Q=n_+-n_-,\qquad m>0,\quad u>0.

    These are two charged modes with a specified repulsive interaction, not the full spectrum of a relativistic field theory. In three spatial dimensions [V]=−3[V]=-3 and [u]=−2[u]=-2, so u/Vu/V has energy units. The quadratic growth makes the ensemble stable for every real μ\mu. The vacuum energy is zero.

    For μ≥0\mu\geq0, adding negative charge always costs energy. The minimum has n−=0n_-=0, and the remaining grand energy is

    Kn=(m−μ)n+u2Vn2,Kn+1−Kn=m−μ+uV(n+12).K_n=(m-\mu)n+\frac{u}{2V}n^2, \qquad K_{n+1}-K_n=m-\mu+\frac{u}{V}\left(n+\frac12\right).

    Consequently the first onset occurs at μ+(V)=m+u/(2V)\mu_+(V)=m+u/(2V), and successive occupations cross at μn=m+u(n+1/2)/V\mu_n=m+u(n+1/2)/V. Away from crossings the minimizing nonnegative integer is the one nearest V(μ−m)/uV(\mu-m)/u, with zero chosen when that continuous minimum lies below the allowed range. Charge conjugation gives the negative-μ\mu staircase.

    For m=1m=1 and u/V=0.4u/V=0.4, the first three crossings are μ=1.2,1.6,2.0\mu=1.2,1.6,2.0. At μ=1.0\mu=1.0 the vacuum is still the unique zero-temperature state. At μ=1.4\mu=1.4 it has been replaced by one positive-charge quantum, and at μ=1.8\mu=1.8 by two. No spontaneous symmetry breaking is needed for these finite-volume level crossings.

    The complete finite-temperature trace factorizes:

    Z=Z+Z−,Z±=∑n=0∞exp⁡[−β((m∓μ)n+u2Vn2)].Z=Z_+Z_-,\qquad Z_\pm=\sum_{n=0}^{\infty}\exp\left[-\beta\left((m\mp\mu)n+\frac{u}{2V}n^2\right)\right].

    Differentiation gives ⟨Q⟩=⟨n+⟩−⟨n−⟩\langle Q\rangle=\langle n_+\rangle-\langle n_-\rangle and ∂μ⟨Q⟩=βVar⁡(Q)≥0\partial_\mu\langle Q\rangle=\beta\operatorname{Var}(Q)\geq0. At small positive TT, below the first crossing,

    ⟨Q⟩=e−β(m+u/(2V)−μ)−e−β(m+u/(2V)+μ)+smaller terms.\langle Q\rangle=e^{-\beta(m+u/(2V)-\mu)}-e^{-\beta(m+u/(2V)+\mu)}+\text{smaller terms}.

    Thus the plateau is exact only at zero temperature. Near the first crossing, when T≪u/VT\ll u/V and antiparticles are suppressed, only n+=0,1n_+=0,1 contribute appreciably:

    ⟨Q⟩≃11+eβ(μ+(V)−μ).\langle Q\rangle\simeq\frac{1}{1+e^{\beta(\mu_+(V)-\mu)}}.

    The Fermi-function shape here describes competition between two charge sectors of a bosonic system. It does not change the particles' statistics. Exactly at the crossing the thermal T→0T\to0 limit gives equal weights and mean charge 1/21/2; a separately selected ground state can instead have charge zero or one.

    A bulk onset is a statement about density

    Now let V→∞V\to\infty with uu fixed, and write ρ=n+/V\rho=n_+/V. For nonnegative μ\mu, minimizing the energy density gives

    KV=(m−μ)ρ+u2ρ2,ρ∗={0,μ≤m,(μ−m)/u,μ>m.\frac{K}{V}=(m-\mu)\rho+\frac u2\rho^2, \qquad \rho_* =\begin{cases}0,&\mu\leq m,\\(\mu-m)/u,&\mu>m.\end{cases}

    The vacuum-subtracted pressure becomes

    p(μ)={0,0≤μ≤m,(μ−m)2/(2u),μ>m,∂p∂μ=ρ∗.p(\mu)=\begin{cases}0,&0\leq\mu\leq m,\\(\mu-m)^2/(2u),&\mu>m,\end{cases} \qquad \frac{\partial p}{\partial\mu}=\rho_*.

    The finite-volume threshold approaches mm, while the individual steps in density shrink as 1/V1/V. This is a soluble thermodynamic limit of the two-mode model, not a derivation of the equation of state of an interacting relativistic gas. The model contains no spatial propagation or Goldstone dispersion; those require the field theory in relativistic Bose condensation.

    The limiting question matters. Taking T→0T\to0 at a fixed finite-volume crossing leaves a degeneracy. Taking V→∞V\to\infty at a fixed μ>m\mu>m yields an extensive occupation. In a canonical ensemble with fixed nonzero QQ, the factor eβμQe^{\beta\mu Q} cancels from normalized expectations: chemical-potential independence within that sector does not imply a zero-density vacuum. Onset concerns competition between sectors in the grand ensemble.

    A neutral state does not freeze charged frequencies

    Let an annihilation operator a+a_+ obey [Q,a+]=−a+[Q,a_+]=-a_+. Since HH and QQ commute, its imaginary-time evolutions satisfy

    a+,K(τ)=eτKa+e−τK=eμτa+,H(τ).a_{+,K}(\tau)=e^{\tau K}a_+e^{-\tau K}=e^{\mu\tau}a_{+,H}(\tau).

    In the vacuum region of our interacting two-mode model, the exact τ>0\tau>0 correlator is

    ⟨0∣a+,K(τ)a+†(0)∣0⟩=e−[m+u/(2V)−μ]τ.\langle0|a_{+,K}(\tau)a_+^\dagger(0)|0\rangle =e^{-[m+u/(2V)-\mu]\tau}.

    The state is unchanged, yet the energy measured relative to KK moves toward zero. Even though this two-point function has zero total charge, its individually charged insertions retain these frequency shifts. For insertions commuting with QQ, the HH and KK evolutions agree; their vacuum correlator is independent of μ\mu throughout the plateau. Explicitly source-dependent observables must also include their own source dependence.

    A Gaussian example shows how the same statement appears in a functional representation. For a free complex oscillator of frequency mm, choose inverse Euclidean transform e−iωτe^{-i\omega\tau}. At zero temperature,

    Cμ(τ)=∫−∞∞dω2π e−iωτ(ω−iμ)2+m2=e−m∣τ∣+μτ2m,∣μ∣<m.C_\mu(\tau)=\int_{-\infty}^{\infty}\frac{d\omega}{2\pi}\, \frac{e^{-i\omega\tau}}{(\omega-i\mu)^2+m^2} =\frac{e^{-m|\tau|+\mu\tau}}{2m},\qquad |\mu|<m.

    Set z=ω−iμz=\omega-i\mu. The contour runs along Im⁡z=−μ\operatorname{Im}z=-\mu and can be moved to the real axis without crossing either pole at z=±imz=\pm im. The exponential contributes eμτe^{\mu\tau}. At equal time the result is Cμ(0)=1/(2m)C_\mu(0)=1/(2m): an explicitly shifted denominator integrates to a constant. For positive τ\tau, the charged decay energy is m−μm-\mu.

    The condition ∣μ∣<m|\mu|<m is essential. At ∣μ∣=m|\mu|=m a pole obstructs this deformation and the free bosonic grand trace ceases to converge. Analytically continuing a formal integral beyond that point does not repair the unstable ensemble. Interactions or another phase must supply the physical continuation. Likewise, a finite-temperature Matsubara sum cannot generally be treated as an unrestricted shift of a continuous integration contour.

    The calculation companion examples/thermal/finite-density/onset-pairing/checks.py sums the interacting trace with increasing occupation cutoff, checks the fluctuation identity and level crossings, and integrates the Gaussian frequency representation directly. Its volume study resolves the staircase approaching the stated bulk density.

    Summary

    The zero-temperature onset is the smallest allowed energy per conserved charge, including collective charged sectors. Below it, the neutral vacuum and its charge-neutral dynamics remain unchanged. Thermal occupation, charged frequency shifts, fixed-charge ensembles and thermodynamic limits answer different questions. The exact interacting occupation model makes those distinctions visible without requiring a solution of finite-density QCD.

    Exercises

    1. A bound state changes the first onset

    A finite system has charge sectors with lowest pairs (q,E−E0)=(0,0),(1,m),(2,1.6m),(3,3m)(q,E-E_0)=(0,0),(1,m),(2,1.6m),(3,3m), where m>0m>0. For μ≥0\mu\geq0, determine the ground-state charge, all changes of that charge, and whether the charge-one sector ever wins.

    Solution

    Put x=μ/mx=\mu/m. The four grand energies in units of mm are 00, 1−x1-x, 1.6−2x1.6-2x, and 3−3x3-3x. Their energy-per-charge ratios are 11, 0.80.8, and 11. Thus the first charged state is the charge-two bound state at x=0.8x=0.8.

    It crosses the charge-three state when 1.6−2x=3−3x1.6-2x=3-3x, or x=1.4x=1.4. Between these crossings its grand energy lies below both zero and 1−x1-x. The ground-state charges are therefore 00 for 0≤x<0.80\leq x<0.8, 22 for 0.8<x<1.40.8<x<1.4, and 33 for x>1.4x>1.4, with the adjacent sectors degenerate at each boundary. Charge one never minimizes the grand energy: below x=0.8x=0.8 the vacuum is cheaper, and above it charge two is already cheaper. The onset cannot be inferred from the charge-one gap alone.

    2. Resolve the onset before taking the limit

    In the two-mode model, take T≪u/VT\ll u/V, μ=μ+(V)+xT\mu=\mu_+(V)+xT with fixed real xx, and negligible negative-charge occupation. Calculate the mean charge, susceptibility and their T→0T\to0 behavior. What changes if μ<μ+(V)\mu<\mu_+(V) is instead held fixed?

    Solution

    The two relevant grand energies are 00 and −xT-xT, so the normalized charge-one probability is P1=ex/(1+ex)P_1=e^x/(1+e^x). Hence

    ⟨Q⟩=11+e−x,∂μ⟨Q⟩=14Tcosh⁡2(x/2).\langle Q\rangle=\frac{1}{1+e^{-x}},\qquad \partial_\mu\langle Q\rangle=\frac{1}{4T\cosh^2(x/2)}.

    The variance is P1(1−P1)P_1(1-P_1), so the second formula also verifies the fluctuation identity. At x=0x=0 the mean is 1/21/2 and the susceptibility is 1/(4T)1/(4T). For any fixed xx, narrowing the thermal crossover preserves its fractional occupation while its slope diverges. As a distribution in μ\mu, that slope approaches a delta function of unit integrated weight, expressing the jump in charge. If the distance μ+(V)−μ>0\mu_+(V)-\mu>0 is fixed first, x→−∞x\to-\infty as T→0T\to0; the mean charge and susceptibility both vanish exponentially. Resolving the moving crossover is different from taking the limit at a fixed interior point of the plateau.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.