Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    The Magnetic Scale and the Linde Problem

    How can an arbitrarily weakly coupled plasma contain a contribution that no finite number of Feynman diagrams determines? The answer is that its static magnetic fields explore arbitrarily long wavelengths. In a non-Abelian theory, their effective coupling grows as the momentum decreases.

    For the pressure of a hot gauge theory in three spatial dimensions, this becomes unavoidable at order g6T4g^6T^4. The coefficient of g6T4log⁡(1/g)g^6T^4\log(1/g) is perturbatively calculable; the finite term at the same power of gg contains a nonperturbative magnetic contribution. We will derive this distinction, including why adding further loops does not resolve it.

    Preparation: Vacuum-diagram loop counting and the separation of electric and magnetic fields in electrostatic and magnetostatic gauge theories. The argument below restates the reduced theory it needs.

    The coupling becomes a momentum scale

    Consider pure SU(Nc)SU(N_c) Yang–Mills theory in thermal equilibrium at zero chemical potential, with NcN_c fixed and g≪1g\ll1. Here gg is the four-dimensional renormalized coupling at a scale of order TT, and p=(T/V)log⁡Zp=(T/V)\log Z is the pressure, with its zero-temperature subtraction understood. We assume there are no additional light scalar fields or other critical modes.

    Integrating out the nonzero Matsubara modes, and then the electrically screened field A0A_0 with mass of order gTgT, leaves the magnetostatic theory, MQCD. In canonical three-dimensional normalization its leading action is

    SM=∫d3x 14FijaFija,Fija=∂iAja−∂jAia+gMfabcAibAjc.S_M=\int d^3x\,\frac14F_{ij}^aF_{ij}^a, \qquad F_{ij}^a=\partial_iA_j^a-\partial_jA_i^a+g_M f^{abc}A_i^bA_j^c.

    The field and coupling have dimensions [Ai]=1/2[A_i]=1/2 and [gM2]=1[g_M^2]=1. At leading order, gM2=g2T[1+O(g)]g_M^2=g^2T[1+O(g)]. The relative O(g)O(g) correction includes integrating out the electric scale; it need not start at g2g^2. Higher-dimensional operators are suppressed in the weak-coupling limit. These are the normalization and matching statements behind Laine and Vuorinen, §6.2, Eq. (6.43), after rescaling their static field by T\sqrt T.

    A loop at characteristic momentum kk brings a dimensionless factor of order

    ϵM(k)∼CAgM24πk,CA=Nc.\epsilon_M(k)\sim\frac{C_Ag_M^2}{4\pi k},\qquad C_A=N_c.

    Numerical factors matter in an actual calculation, but the parametric conclusion is immediate: at fixed NcN_c, perturbation theory loses its small parameter when k∼gM2∼g2Tk\sim g_M^2\sim g^2T. Electric screening has not removed these spatial gauge fields. A local term m2AiaAiam^2A_i^aA_i^a is not gauge invariant, so the Debye-mass resummation of A0A_0 cannot simply be copied into the magnetic action. The magnetic theory instead has its own strongly interacting, confining infrared dynamics.

    Counting the infrared power of a vacuum graph

    Let a connected magnetostatic vacuum graph have V3V_3 cubic vertices, V4V_4 quartic vertices, II internal lines and LL loops. For the counting, a ghost–gauge vertex is a cubic vertex with one derivative, and a ghost propagator also scales as k−2k^{-2}. The incidence and connectivity identities are

    3V3+4V4=2I,L=I−V3−V4+1.3V_3+4V_4=2I,\qquad L=I-V_3-V_4+1.

    Each cubic vertex supplies gMkg_Mk, each quartic vertex supplies gM2g_M^2, each propagator supplies k−2k^{-2}, and each independent integration supplies k3k^3. Consequently

    V3+2V4=2(L−1),3L+V3−2I=4−L.V_3+2V_4=2(L-1),\qquad 3L+V_3-2I=4-L.

    The contribution of a momentum region where all loop momenta are of order kk therefore scales as

    fM,L∼(gM2)L−1k4−L.f_{M,L}\sim(g_M^2)^{L-1}k^{4-L}.

    Here fM=−V−1log⁡ZMf_M=-V^{-1}\log Z_M has mass dimension three. This is power counting, not a value or sign for an individual graph: color factors, angular integrals, subtractions and cancellations still have to be calculated. It identifies when the infrared can invalidate a loop expansion.

    Loops LLCommon-momentum infrared degreeConsequence as the infrared cutoff decreases
    2k2k^2No overall infrared divergence
    3kkNo overall infrared divergence
    4k0k^0Logarithmic sensitivity
    5k−1k^{-1}Power sensitivity
    L>4L>4k4−Lk^{4-L}Increasing power sensitivity

    At four loops, zero degree means an integral over scale of the form ∫dk/k\int dk/k, rather than independence of the integration range. Higher loops are still worse. Subdivergences and gauge cancellations require their own treatment, but the four-loop magnetic vacuum-energy logarithm is nonzero: it is exhibited explicitly in Kajantie, Laine, Rummukainen and Schröder, §III, Eqs. (3.1)–(3.3).

    Now use the scale generated by the magnetic theory itself. For every L≥4L\geq4,

    (gM2)L−1(gM2)4−L=(gM2)3,T(gM2)3∼g6T4.(g_M^2)^{L-1}(g_M^2)^{4-L}=(g_M^2)^3, \qquad T(g_M^2)^3\sim g^6T^4.

    Thus five-, six- and arbitrarily high-loop infrared contributions enter at the same power of the four-dimensional coupling. There is no finite last diagram whose evaluation would supply the magnetic constant. This is the pressure version of the Linde problem.

    A calculable logarithm and a nonperturbative constant

    The pressure can be separated into matching contributions from the hard and electric scales and a magnetic free energy:

    p=phard+pelectric−TfM.p=p_{\rm hard}+p_{\rm electric}-Tf_M.

    The separate terms depend on the factorization prescription. For example, after ultraviolet subtraction in a specified continuum scheme, the leading magnetic term has the structure

    fM(μˉM)=(gM2)3[clog⁡log⁡μˉMgM2+cM].f_M(\bar\mu_M)=(g_M^2)^3\left[c_{\log}\log\frac{\bar\mu_M}{g_M^2}+c_M\right].

    μˉM\bar\mu_M is the three-dimensional subtraction scale; group factors have been included in clog⁡c_{\log} and cMc_M. The four-loop ultraviolet logarithm determines clog⁡c_{\log} perturbatively. The finite constant cMc_M requires nonperturbative information in that same scheme. A different convention for the logarithm's argument shifts cMc_M, and the scale dependence cancels against the matching terms in the full pressure. The magnetic constant by itself is not an observable.

    This explains the schematic weak-coupling series, at a fixed four-dimensional renormalization scale divided by TT:

    pT4=c0+c2g2+c3g3+g4[c4log⁡(1/g)+d4]+c5g5+⋯ .\frac{p}{T^4}=c_0+c_2g^2+c_3g^3+g^4[c_4\log(1/g)+d_4]+c_5g^5+\cdots.

    Its next terms are g6[c6log⁡(1/g)+d6]g^6[c_6\log(1/g)+d_6]. The coefficient c6c_6 is perturbative. The coefficient d6d_6 contains both perturbative matching pieces and the nonperturbative magnetic constant. The order is also called αs3\alpha_s^3, with αs=g2/(4π)\alpha_s=g^2/(4\pi); this change of notation does not postpone the obstruction. The separation is explicit in Kajantie et al., §§III and VI.

    Two tempting shortcuts fail. First, strictly massless vacuum integrals vanish in dimensional regularization because they are scaleless. Here that zero hides a cancellation between ultraviolet and infrared singularities; it does not establish that the magnetic pressure vanishes. Second, inserting a guessed magnetic mass may regulate diagrams, but the resulting finite constant depends on the prescription. It does not determine the gauge-invariant MQCD free energy. A nonperturbative computation, for example a lattice calculation with the necessary conversion to the continuum subtraction scheme, supplies the missing input.

    Worked diagnostic: lowering an infrared cutoff

    Write q=gM2q=g_M^2 and consider the radial model integral

    JL(m,Λ)=qL−1∫mΛdk k3−L.J_L(m,\Lambda)=q^{L-1}\int_m^\Lambda dk\,k^{3-L}.

    This is a diagnostic of the common-scale power count, not a Yang–Mills multiloop integral. Its coefficients must not be used as pressure coefficients. For L=4L=4 the result J4=q3log⁡(Λ/m)J_4=q^3\log(\Lambda/m) is logarithmic. For L>4L>4 the integral gives

    JL=qL−1L−4(m4−L−Λ4−L).J_L=\frac{q^{L-1}}{L-4}\left(m^{4-L}-\Lambda^{4-L}\right).

    At Λ=100q\Lambda=100q, the exact normalized results are:

    LLJL/q3J_L/q^3 at m=qm=qJL/q3J_L/q^3 at m=0.1qm=0.1q
    4log⁡100=4.605170\log100=4.605170log⁡1000=6.907755\log1000=6.907755
    50.990.999.999.99
    60.499950.4999549.9999549.99995

    At m∼qm\sim q, every row is of order q3q^3 up to the logarithm. Pushing a perturbative calculation further below qq produces increasing sensitivity, rather than increasing control. Conversely, cutting it off at m∼gTm\sim gT discards the physical magnetic region. The cutoff mm in this diagnostic is an integration boundary, not a proposed gluon mass.

    The reproducible companion in examples/thermal/thermal-effective-theories/magnetic-ultrasoft/ checks the graph-counting identities and evaluates these integrals by numerical quadrature. It tests the displayed scaling and numbers; it does not compute cMc_M.

    What this argument does and does not imply

    The obstruction belongs to the infrared sector of a specified observable. It does not prevent calculating lower pressure orders or perturbatively matching the effective theory. It also does not imply that every thermal observable first becomes nonperturbative at g6g^6: a magnetic correlation length already has nonperturbative leading behavior.

    For a noncompact Abelian theory with no light charged matter left in its magnetostatic sector, the leading magnetic action is free Maxwell theory. It has no non-Abelian self-interaction vertices and no corresponding Linde graph tower. Compact gauge theories or theories with additional light matter require a separate analysis.

    Finally, SMS_M determines static probabilities. It does not specify how fast a magnetic configuration changes. That extra question leads to the conductivity and noise in ultrasoft gauge dynamics.

    Summary

    In three-dimensional Yang–Mills theory the loop parameter is proportional to gM2/kg_M^2/k. Vacuum diagrams become logarithmically infrared sensitive at four loops and power sensitive above four loops. At the magnetic scale k∼gM2k\sim g_M^2, all these infrared contributions have size T(gM2)3∼g6T4T(g_M^2)^3\sim g^6T^4. Matching determines the logarithms and the contributions of the larger scales; a nonperturbative magnetic free energy determines the remaining finite constant in a specified scheme.

    Exercises

    1. Can a screening mass restore the loop hierarchy?

    Suppose, only for power counting, that an infrared scale m∼gaTm\sim g^aT cuts off the common-momentum region of an LL-loop magnetic graph. Find its power of gg in the four-dimensional pressure. Compare a=1a=1 and a=2a=2, and explain why the first choice does not solve the physical magnetic problem.

    Solution

    Using gM2∼g2Tg_M^2\sim g^2T gives

    T(g2T)L−1(gaT)4−L=T4g(2−a)L+4a−2.T(g^2T)^{L-1}(g^aT)^{4-L}=T^4g^{(2-a)L+4a-2}.

    For a=1a=1, the power is gL+2g^{L+2}: each additional loop costs gg. This is the kind of hierarchy available for fluctuations with a genuine electric mass of order gTgT. For a=2a=2, the power is g6g^6 for every loop. A logarithm can multiply the four-loop result without changing this power.

    The spatial non-Abelian gauge field does not acquire a Debye mass. Imposing m∼gTm\sim gT in that sector removes momenta between g2Tg^2T and gTgT and replaces the infrared theory with a different one. Even a cutoff m=cg2Tm=cg^2T with a chosen constant cc leaves higher loops unsuppressed and their finite answers dependent on cc.

    2. A change of subtraction scale

    Let q=gM2q=g_M^2 be fixed at the order considered and let fM=q3[clog⁡log⁡(μˉM/q)+cM]f_M=q^3[c_{\log}\log(\bar\mu_M/q)+c_M] denote the magnetic free-energy density. If μˉM→esμˉM\bar\mu_M\to e^s\bar\mu_M, what change in phard+pelectricp_{\rm hard}+p_{\rm electric} keeps pp fixed? If the logarithm is instead written as log⁡[μˉM/(bq)]\log[\bar\mu_M/(bq)] at the original scale, how must its finite constant change?

    Solution

    The scale change increases fMf_M by q3clog⁡sq^3c_{\log}s, so the magnetic pressure −TfM-Tf_M decreases by Tq3clog⁡sTq^3c_{\log}s. The sum of matching contributions must increase by exactly that amount. This cancellation is required through the order being retained, not separately in each region.

    Since log⁡[μˉM/(bq)]=log⁡(μˉM/q)−log⁡b\log[\bar\mu_M/(bq)]=\log(\bar\mu_M/q)-\log b, preserving fMf_M requires cM→cM+clog⁡log⁡bc_M\to c_M+c_{\log}\log b. A quoted magnetic constant without its scheme and logarithm convention is therefore incomplete.

    References

    • K. Kajantie, M. Laine, K. Rummukainen and Y. Schröder, “The pressure of hot QCD up to g6ln⁡(1/g)g^6\ln(1/g),” Physical Review D 67, 105008 (2003), arXiv:hep-ph/0211321v2 (PDF). §§II–III, especially Eqs. (2.18)–(2.19) and (3.1)–(3.3), distinguish the magnetic free energy, its calculable logarithm and its finite constant; §VI combines the scales.
    • M. Laine and A. Vuorinen, Basics of Thermal Field Theory: A Tutorial on Perturbative Computations, arXiv:1701.01554v2 (PDF). §6.1 explains thermal loop counting; §6.2, Eq. (6.43) and the following discussion give MQCD and its one dimensionful coupling.

    Further reading

    • A. D. Linde, “Infrared problem in the thermodynamics of the Yang–Mills gas,” Physics Letters B 96, 289–292 (1980), doi:10.1016/0370-2693(80)90769-8. The original paper identifying the magnetic infrared obstruction.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.