- Home
- Library
- Thermal and Nonequilibrium Field Theory
- Hydrodynamic Noise, Tails, and Slow Modes
- Additional Slow Modes near Criticality
Additional Slow Modes near Criticality
A fluid can be soft under slow compression and stiff under fast compression. An internal degree of freedom rearranges during a slow experiment, lowering the pressure cost. When the compression outruns its relaxation, that rearrangement is unavailable. Near a critical point, the separation between these two experiments can move into the hydrodynamic frequency range.
We solve a fluid coupled to one relaxing scalar. The same model gives a frequency-dependent bulk viscosity, two limiting sound moduli, a third relaxation mode and a positive dissipation law. It is a controlled linear example of an enlarged slow sector; it does not calculate critical exponents or replace the continuum of fluctuation modes in Hydro+.
Preparation: Linear fluid modes, bulk response and equilibrium response. Frequencies use ; a stable pole has .
When eliminating an internal variable fails
Ordinary hydrodynamics retains conserved densities because their rates vanish as wavelength grows. It eliminates other variables by assuming that they reach local equilibrium before the fluid changes appreciably. A nonconserved variable can violate that assumption if its relaxation rate becomes independently small.
The useful hierarchy is then
where is the relaxation scale of omitted microscopic variables. The ratio need not be small. Keeping the extra variable makes the equations local in time; eliminating it exactly produces a memory kernel. Expanding that kernel in is permissible only in the smaller ordinary-hydrodynamic regime.
This separation is central to Stephanov and Yin, §II.A and the end of §II.B. Their relativistic tensors use mostly-plus signature. The rest-frame scalar and physical-pressure equations used here are derived below in the site's mostly-minus convention, without importing their tensor components.
A stable quadratic model of compression
Work near homogeneous equilibrium at temperature , enthalpy density and zero velocity. In a longitudinal, adiabatic channel define the dimensionless compression ; if a conserved charge participates, its ideal adiabatic perturbation satisfies . Charge or heat diffusion is omitted in this illustrative channel.
Let be a dimensionless internal scalar, with preferred value . A quadratic availability for the disturbance is
Availability is the quadratic thermodynamic cost that can be dissipated into heat, rather than the complete conserved energy of the fluid. Its coefficients have units of energy density; is dimensionless. Define the departure . The pressure perturbation conjugate to compression is
Thus an equilibrated scalar gives modulus , while one held fixed gives modulus . The pressure feedback is fixed by this thermodynamic cost, not chosen separately from the relaxation equation.
The linear equations are
The first two express linear energy and momentum conservation. The third is downhill relaxation, . Background coefficients are constant; this is a linear rest-frame model, not a full nonlinear covariant constitutive theory.
For periodic boundaries or disturbances with no boundary flux, integration by parts gives
Indeed, contains ; the first two combine into a boundary divergence. The remaining term is negative. At quadratic order the local heat production is , and the corresponding deterministic entropy production is . Including that heat restores the second-order energy accounting. Noise and fluctuating entropy require the additional treatment in fluctuating conservation laws.
Eliminate the scalar without losing its initial condition
Write , and . The coupled equations imply
The exact solution starting at is
There is a homogeneous term whenever the internal mode is initially out of equilibrium. Dropping it imposes a preparation, not an identity. For a steady harmonic response after that transient has decayed,
Because , the compressional modulus is
For real frequency,
The two moduli are and . The subscript means , or the frozen-scalar limit inside this effective model. It is not a prediction for arbitrarily high microscopic frequency.
Only describes dissipation. The imaginary part describes the delayed, elastic response. For , the average work deposited per unit volume per unit time is
Solving for also gives equal to this expression. The equality tests both the Fourier sign and the pressure feedback. The zero-frequency contribution obeys
This matches the one-mode relation in Stephanov and Yin, §II.B, Eqs. (22)–(33). Their positive combination corresponds to our , and their to our ; their scalar normalization need not equal ours.
What the bulk Kubo formula measures
At finite density, pressure contains a piece due simply to changing the conserved energy and charge. To isolate the dissipative bulk channel, use the projected operator
where and are derivatives of the equilibrated equation of state. This removes the ordinary adiabatic pressure response, as derived in viscosity correlators.
Within our slow sector, holding the conserved densities fixed sets and makes . A weak source coupled as changes the local cost to . Downhill relaxation becomes . It follows that
Thus the viscosity's sign agrees with the site's retarded convention. Moreover,
The static subtraction matters: a geometric compressional response includes equilibrium elastic and contact contributions. The modulus itself is not an unqualified bare stress commutator. Additional fast-sector viscosity can be included as a separate nonnegative low-frequency background; our numerical example sets it to zero to isolate the slow scalar.
Solve the three longitudinal modes
For dependence , with , eliminate and to obtain
There are three modes, not merely sound with a large constant attenuation coefficient. For and , all coefficients of the monic cubic are positive, and its Routh–Hurwitz inequality is
Hence every root has . The positive availability gives an independent stability explanation. If , the scalar decouples and the sound pair is undamped in this idealized model. At there are two conserved zero modes and one mode with .
At small , the sound roots are
At frequencies large compared with but still below the omitted scales, their speed approaches and their decay rate approaches . The remaining scalar root approaches . A relativistic embedding requires the frozen characteristic speed as well as stability; positivity alone does not enforce that bound or prove nonlinear covariant causality.
For , , , and , we have , and . All dimensional numbers are expressed using one reference energy scale. Direct diagonalization of the three-variable evolution gives:
| Scalar decay rate | |||
|---|---|---|---|
The large- rows test the mathematical model's frozen regime. Applying them to a particular fluid would require its fast relaxation and microscopic length scales to remain well separated. A constant would predict attenuation indefinitely; that approximation already fails across this table.
Evolve a disturbance and test the response
The companion in examples/thermal/fluctuating-hydrodynamics/hydrostatic-critical/ uses two independent spatial treatments. On a periodic interval of length , start with
One calculation evolves the real-space equations using a centered spatial derivative and adaptive time integration. Another propagates each continuum Fourier mode with the exact three-by-three matrix exponential. At , the errors are , and on 32, 64 and 128 points. Each error is the root mean square over all three fields. The ratios and confirm second-order spatial convergence. Tightening time tolerances changes the finest-grid fields by or less, so time error does not explain that convergence.
The real-space calculation separately integrates the produced heat. Availability plus accumulated heat stays constant to about relative, and the spatially averaged conserved compression remains zero within rounding error. The grid derivative has a discrete integration-by-parts identity, so this balance is meaningful at every resolution even before the continuum error vanishes.
A separate forced-compression evolution starts at zero, waits for its transient to decay, and fits the pressure's sine and cosine components. For it obtains
The fitted complex responses agree with the analytic kernel within in this run. Independently integrated cycle work and relaxation heat agree with the positive dissipation formula.
Critical fluctuations require more than one relaxation pole
If decreases at fixed , the zero-frequency viscosity grows like , but its domain of frequency-independent validity shrinks. At any fixed nonzero frequency, sending instead gives the frozen modulus and vanishing dissipative part. A divergent low-frequency coefficient is therefore not evidence for arbitrarily strong damping at every frequency.
Near a genuine critical point, equilibrium susceptibilities and couplings also depend on the correlation length. The slow variables can be fluctuations of a conserved density or entropy per particle, rather than the mean of a separate elementary scalar. Coupling and conservation determine which modes are independently slow. Critical dynamics is classified by these physical ingredients, not by the mere presence of a field called ; see dynamic universality.
In the fluctuation formulation of Hydro+, a family of local two-point fluctuation amplitudes is labeled by an internal wave vector . This label differs from the long-wavelength fluid wave vector . Schematically the single pole is replaced by
The weight includes the thermodynamic coupling of each fluctuation mode to pressure and must be matched along with the rate and coarse-graining range. Stephanov and Yin, §V.B, Eqs. (99)–(103) and the discussion of Fig. 4 derives this continuum response. A continuum can have nonanalytic low-frequency behavior that no single relaxation pole reproduces. Our one-mode example establishes the mechanism of delayed equilibration and stiffening; it supplies neither that continuum weight nor a dynamic critical exponent.
Summary
A slow scalar contributes a retarded bulk kernel . Its positive thermodynamic cost guarantees nonnegative absorption and stable coupled modes. Equilibrated sound measures , while faster sound measures within the effective regime. Keeping the scalar resolves the failure of a constant-viscosity approximation; treating actual critical fluctuations requires a matched set of slow modes and their equilibrium statistics.
Exercises
1. A sudden compression. Prepare , , then impose a small compression at and hold it fixed. Find the pressure, the total relaxation heat and the work of the ideal instantaneous step. What changes if the compression is quasistatic?
Solution
The scalar cannot change during the idealized step. For ,
The pressure starts at and ends at . The produced heat is
The step puts into availability, of which remains as equilibrated compression. A quasistatic compression lets track and requires only , with vanishing heat in the infinitely slow limit. A sudden protocol lasts much longer than but much less than ; the discontinuous step idealizes this interval of durations.
2. Two internal relaxation times. Replace the scalar cost by , with independent rates . Find the bulk kernel and limiting moduli. Can a single rate reproduce its zero-frequency viscosity and both its first two frequency derivatives in general?
Solution
Each departure relaxes separately and contributes . Therefore
The availability decreases at rate , and each term in is nonnegative. The low-frequency expansion is
For a single pole the coefficients obey , where . Cauchy–Schwarz gives , with equality only when all nonzero weights have the same rate. Thus distinct active rates cannot generally be represented by one pole through second order, even if its amplitude and rate are fitted. Matching the frozen modulus and zero-frequency viscosity alone likewise does not fix the whole frequency response.
References
- P. Kovtun, Lectures on hydrodynamic fluctuations in relativistic theories, arXiv:1205.5040v1, §§2.5–2.6: conserved-density response and variational stress contacts.
- M. Stephanov and Y. Yin, Hydro+: hydrodynamics with parametric slowing down and fluctuations near the critical point, arXiv:1712.10305v1, §§II.A–II.B, Eqs. (22)–(33), and §V.B, Eqs. (99)–(103): one-mode response, sound stiffening and the continuum of critical fluctuation modes.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.