Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Lindblad Field Theory and Complete Positivity

    A damped field mode must lose energy without turning a density matrix into a state with negative probabilities. A complex frequency describes the decay of an amplitude; it does not specify how the missing probability returns to the density matrix. Lindblad evolution supplies both the loss and the accompanying jumps. We construct it for a regulated scalar field, find its stationary state and spectrum, and test what changes when the occupation cutoff is raised.

    Preparation: Reduced field dynamics explains the system–environment split and the approximations behind a master equation. Closed-time paths explains why a density matrix has two evolution branches.

    A scalar field with a finite regulator

    Start with a periodic chain of canonical oscillators. We absorb the cell-volume factor into the coordinates, so [qj,pl]=iδjl[q_j,p_l]=i\delta_{jl}. For lattice spacing aa and positive mass mm,

    H=12∑j=1Ns[pj2+m2qj2+(qj+1−qj)2a2].H=\frac12\sum_{j=1}^{N_s}\left[p_j^2+m^2q_j^2+\frac{(q_{j+1}-q_j)^2}{a^2}\right].

    A real orthogonal normal-mode transformation diagonalizes the positive stiffness matrix. Label its real modes by α\alpha, write their frequencies as ωα\omega_\alpha, and define

    bα=ωα2Qα+iPα2ωα,H=∑αωα(bα†bα+12).b_\alpha=\sqrt{\frac{\omega_\alpha}{2}}Q_\alpha+\frac{iP_\alpha}{\sqrt{2\omega_\alpha}},\qquad H=\sum_\alpha\omega_\alpha\left(b_\alpha^\dagger b_\alpha+\frac12\right).

    There are still infinitely many occupation states per oscillator. A finite-dimensional calculation retains ∣0⟩,…,∣K−1⟩|0\rangle,\ldots,|K-1\rangle in each mode and defines

    bK=∑n=1K−1n ∣n−1⟩⟨n∣,HK=ω∑n=0K−1(n+12)∣n⟩⟨n∣.b_K=\sum_{n=1}^{K-1}\sqrt n\,|n-1\rangle\langle n|,\qquad H_K=\omega\sum_{n=0}^{K-1}\left(n+\frac12\right)|n\rangle\langle n|.

    The finite matrix obeys

    [bK,bK†]=1−K∣K−1⟩⟨K−1∣.[b_K,b_K^\dagger]=1-K|K-1\rangle\langle K-1|.

    Thus HKH_K is the projected number Hamiltonian; replacing it by an expression using a falsely canonical finite matrix would change its top level. We keep this boundary term in every finite-cutoff calculation. The spatial lattice and the occupation cap regulate different things.

    Choose nonnegative target occupations nˉα\bar n_\alpha and positive decay constants κα\kappa_\alpha. The jump operators are

    Lα,−=κα(nˉα+1) bα,K,Lα,+=καnˉα bα,K†.L_{\alpha,-}=\sqrt{\kappa_\alpha(\bar n_\alpha+1)}\,b_{\alpha,K},\qquad L_{\alpha,+}=\sqrt{\kappa_\alpha\bar n_\alpha}\,b_{\alpha,K}^\dagger.

    Here κ\kappa is an occupation-relaxation rate in the unbounded oscillator limit. It is unrelated to the momentum-diffusion coefficient used in the heavy-probe article. These are normal-mode jumps and are generally nonlocal in the site coordinates. Relativistic locality and the continuum limit would require additional structure beyond this finite lattice.

    Trace preservation and complete positivity

    The generator is

    ρ˙=Lρ=−i[HK,ρ]+∑ℓ(LℓρLℓ†−12{Lℓ†Lℓ,ρ}).\dot\rho=\mathcal L\rho=-i[H_K,\rho]+\sum_\ell\left(L_\ell\rho L_\ell^\dagger-\frac12\{L_\ell^\dagger L_\ell,\rho\}\right).

    Cyclicity of a finite-dimensional trace cancels each recycling term against its two loss terms. Complete positivity is stronger than preserving positive states without an observer: etL⊗1e^{t\mathcal L}\otimes 1 must preserve positivity when the field is entangled with an arbitrary spectator.

    For a short step, introduce

    M0=1−(iHK+12∑ℓLℓ†Lℓ)δt,Mℓ=δt Lℓ.M_0=1-\left(iH_K+\frac12\sum_\ell L_\ell^\dagger L_\ell\right)\delta t,\qquad M_\ell=\sqrt{\delta t}\,L_\ell.

    The map ρ↦∑ℓ≥0MℓρMℓ†\rho\mapsto\sum_{\ell\geq0}M_\ell\rho M_\ell^\dagger is completely positive and equals ρ+δtLρ+O(δt2)\rho+\delta t\mathcal L\rho+O(\delta t^2). Its trace error is O(δt2)O(\delta t^2). At fixed finite dimension the product limit gives etLe^{t\mathcal L}, with vanishing accumulated error and exact trace preservation. This also explains why the anticommutator alone is insufficient: it removes the probability that the jump term restores.

    Conservation is a separate question. An observable AA is conserved for every state only if L†A=0\mathcal L^\dagger A=0. These gain and loss jumps exchange energy with reservoirs. Positivity does not turn them into a closed, energy-conserving field theory.

    For a direct matrix diagnostic, form the normalized Choi matrix

    Ct=1d∑i,j=1d∣i⟩⟨j∣⊗etL(∣i⟩⟨j∣).C_t=\frac1d\sum_{i,j=1}^d |i\rangle\langle j|\otimes e^{t\mathcal L}(|i\rangle\langle j|).

    The channel is completely positive precisely when CtC_t is positive semidefinite. Trace preservation gives a partial trace equal to 1/d1/d, not merely Tr⁡Ct=1\operatorname{Tr}C_t=1. The companion checks the trace functional separately and diagonalizes CtC_t.

    The exact doubled field representation

    Let a many-mode occupation configuration be n\mathbf n. A density matrix has the two labels ∣n+⟩⟨n−∣|\mathbf n_+\rangle\langle\mathbf n_-|. With column vectorization, ∣ρ⟩ ⁣⟩=vec⁡ρ|\rho\rangle\!\rangle=\operatorname{vec}\rho, the exact finite-regulator generator becomes

    L=−i(1⊗HK−HKT⊗1)+∑ℓ[Lℓ∗⊗Lℓ−12(1⊗Lℓ†Lℓ+(Lℓ†Lℓ)T⊗1)].\mathbb L=-i(1\otimes H_K-H_K^T\otimes1)+\sum_\ell\left[L_\ell^*\otimes L_\ell-\frac12\left(1\otimes L_\ell^\dagger L_\ell+(L_\ell^\dagger L_\ell)^T\otimes1\right)\right].

    This follows from vec⁡(AρB)=(BT⊗A)vec⁡ρ\operatorname{vec}(A\rho B)=(B^T\otimes A)\operatorname{vec}\rho. The recycling term couples the two branches. Inserting the occupation dyads between factors of 1+δtL1+\delta t\mathbb L gives a discrete field history with a forward and backward configuration at every time. Its initial weight is ρn+n−(t0)\rho_{\mathbf n_+\mathbf n_-}(t_0); the final trace sums equal final configurations. The trace row vector obeys ⟨ ⁣⟨1∣L=0\langle\!\langle1|\mathbb L=0.

    There is also a useful continuous-field description after replacing the capped oscillators by the unbounded Gaussian oscillator model. With br=(b++b−)/2b_r=(b_++b_-)/2 and ba=b+−b−b_a=b_+-b_-, its bulk coherent-state action is

    S=∫dt[ba∗(i∂t−ω+iκ/2)br+br∗(i∂t−ω−iκ/2)ba+iκ(nˉ+1/2)∣ba∣2].S=\int dt\left[b_a^*(i\partial_t-\omega+i\kappa/2)b_r+b_r^*(i\partial_t-\omega-i\kappa/2)b_a+i\kappa(\bar n+1/2)|b_a|^2\right].

    The initial density kernel and final trace sewing accompany this action. The positive imaginary quadratic term damps differences between branches in eiSe^{iS}. It is not an exact replacement for the capped dyad sum: the canonical coherent-state construction omits the top-state projector. Sieberer, Buchhold and Diehl, §§ II.1–II.2.1, Eqs. (19), (42)–(47) derive the unbounded loss-only action. Their loss rate is 2κSBD2\kappa_{\rm SBD}, so our κ=2κSBD\kappa=2\kappa_{\rm SBD}; their fields use a 1/21/\sqrt2 rotation. The thermal gain term above adds noise while leaving the net damping fixed.

    Stationary populations and damped spectra

    For a diagonal state, neighboring populations exchange probability at rates proportional to κnˉ(n+1)\kappa\bar n(n+1) upward and κ(nˉ+1)(n+1)\kappa(\bar n+1)(n+1) downward. Zero stationary current on each link gives

    pn+1pn=r=nˉnˉ+1,pn=(1−r)rn1−rK.\frac{p_{n+1}}{p_n}=r=\frac{\bar n}{\bar n+1},\qquad p_n=\frac{(1-r)r^n}{1-r^K}.

    For nˉ=0\bar n=0 this means the vacuum. For nˉ>0\bar n>0 all neighboring levels communicate and the stationary state is unique. The product over modes is a Gibbs state of HKH_K if rα=e−βωαr_\alpha=e^{-\beta\omega_\alpha} with a common β\beta. Different mode temperatures give a stationary product state without a common Gibbs temperature.

    In the unbounded model, the adjoint generator closes on bb and b†bb^\dagger b:

    ∂t⟨b⟩=−(iω+κ/2)⟨b⟩,∂t⟨b†b⟩=−κ(⟨b†b⟩−nˉ).\partial_t\langle b\rangle=-(i\omega+\kappa/2)\langle b\rangle,\qquad \partial_t\langle b^\dagger b\rangle=-\kappa(\langle b^\dagger b\rangle-\bar n).

    Quantum regression then propagates qρssq\rho_{\rm ss} with the same generator as the state. For q=(b+b†)/2ωq=(b+b^\dagger)/\sqrt{2\omega} and t≥0t\geq0,

    Wq>(t)=e−κt/22ω[(nˉ+1)e−iωt+nˉeiωt].W_q^>(t)=\frac{e^{-\kappa t/2}}{2\omega}\left[(\bar n+1)e^{-i\omega t}+\bar n e^{i\omega t}\right].

    Stationarity and Hermiticity supply the negative-time function. With Fourier frequency ν\nu and the site's forward phase eiνte^{i\nu t},

    Wq>(ν)=κ2ω[nˉ+1(ν−ω)2+(κ/2)2+nˉ(ν+ω)2+(κ/2)2].W_q^>(\nu)=\frac{\kappa}{2\omega}\left[\frac{\bar n+1}{(\nu-\omega)^2+(\kappa/2)^2}+\frac{\bar n}{(\nu+\omega)^2+(\kappa/2)^2}\right].

    The commutator yields GR=−θ(t)e−κt/2sin⁡(ωt)/ωG_R=-\theta(t)e^{-\kappa t/2}\sin(\omega t)/\omega. For a Hamiltonian source H′=−JqH'=-Jq, the physical susceptibility is

    χq(ν)=−GR(ν)=1ω2+(κ/2−iν)2.\chi_q(\nu)=-G_R(\nu)=\frac{1}{\omega^2+(\kappa/2-i\nu)^2}.

    Its poles lie at ν=±ω−iκ/2\nu=\pm\omega-i\kappa/2. The noise integral gives ⟨q2⟩=(nˉ+1/2)/ω\langle q^2\rangle=(\bar n+1/2)/\omega. The static susceptibility of this fixed dissipator need not equal the derivative of a family of Gibbs states whose Hamiltonian and dissipator are both rematched to a static source.

    Even when r=e−βωr=e^{-\beta\omega}, the finite-width regression spectrum does not satisfy Wq>(−ν)=e−βνWq>(ν)W_q^>(-\nu)=e^{-\beta\nu}W_q^>(\nu) at every ν\nu. The jump rates impose detailed balance at the oscillator's Bohr frequency. Their constant-rate, Markovian extension spreads each line into a Lorentzian; its distant tails do not reconstruct the exact microscopic bath. In the weak-damping, resolved-line limit the thermal weights are recovered. Quantum noise instead uses an explicitly frequency-dependent bath satisfying exact KMS before taking detector limits.

    Cutoff convergence is observable dependent

    The companion examples/thermal/open-systems/noise-probe/ exponentiates the finite Liouvillian and computes its resolvent spectrum. At ω=1.3\omega=1.3, κ=0.24\kappa=0.24 and nˉ=0.7\bar n=0.7, it compares 81 finite-spectrum samples with the unbounded result. The error below is the maximum absolute difference divided by the maximum unbounded spectrum on that grid.

    Occupation cap KK⟨bK†bK⟩\langle b_K^\dagger b_K\rangleTop-level probabilitySpectrum error
    40.581607504.23×10−24.23\times10^{-2}4.27×10−14.27\times10^{-1}
    80.693383291.18×10−31.18\times10^{-3}5.03×10−25.03\times10^{-2}
    120.699714913.39×10−53.39\times10^{-5}3.33×10−33.33\times10^{-3}
    160.699989079.76×10−79.76\times10^{-7}1.72×10−41.72\times10^{-4}
    200.699999612.80×10−82.80\times10^{-8}7.74×10−67.74\times10^{-6}

    The mean occupation converges before the narrow spectral peak. Small top-level weight alone is not an error estimate for every observable. Trace and stationary-state residuals stay below 9×10−169\times10^{-16}, while the finite-time Choi matrices at K=3,5K=3,5 are positive. Changing the pumping coefficient from 0.7κ0.7\kappa to −0.05κ-0.05\kappa preserves trace but produces Choi eigenvalues −0.00401-0.00401 and −0.00654-0.00654 at t=0.4t=0.4.

    A two-site test uses m=a=1m=a=1, frequencies 1,51,\sqrt5, β=1.2\beta=1.2, and four states per mode. Doubled-space evolution gives 0.28516317−0.24415668i0.28516317-0.24415668i at t=0.73t=0.73, agreeing with the separately evolved mode sum within 2×10−162\times10^{-16}. This checks the field reconstruction as well as a single oscillator. It is a fixed spatial-regulator test, not evidence for a relativistic continuum theory.

    Summary

    A finite-regulator GKSL generator supplies a trace-preserving completely positive field evolution, and its doubled occupation representation remains exact at the cap. The Gaussian oscillator limit yields analytic poles and spectra, but population convergence, spectral convergence, microscopic KMS, spatial locality and regulator removal remain distinct questions. Nonlinear driven examples continue in driven steady states.

    Exercises

    1. The exact occupation bias

    Derive the mean occupation of the capped stationary state. Explain why replacing the finite commutator by 11 gives the wrong stationary answer.

    Solution

    From ZK(r)=∑n=0K−1rn=(1−rK)/(1−r)Z_K(r)=\sum_{n=0}^{K-1}r^n=(1-r^K)/(1-r),

    ⟨n⟩K=r∂rlog⁡ZK=r1−r−KrK1−rK=nˉ−KrK1−rK.\langle n\rangle_K=r\partial_r\log Z_K=\frac{r}{1-r}-\frac{Kr^K}{1-r^K}=\bar n-\frac{Kr^K}{1-r^K}.

    A pump cannot take ∣K−1⟩|K-1\rangle to a discarded level. The exact adjoint equation is therefore

    ∂t⟨n⟩=−κ⟨n⟩+κnˉ(1−KpK−1).\partial_t\langle n\rangle=-\kappa\langle n\rangle+\kappa\bar n\left(1-Kp_{K-1}\right).

    Inserting the geometric top-level probability reproduces the bias. The canonical replacement drops its last term and incorrectly predicts ⟨n⟩=nˉ\langle n\rangle=\bar n at every cap.

    2. A thermal stationary state without exact thermal spectral tails

    Set nˉ=0\bar n=0 in the unbounded model. Show that its regression spectrum has weight at negative frequency, and explain why this does not prove that the microscopic zero-temperature bath emits energy.

    Solution

    The regression formula gives

    Wq>(−ω)=κ2ω(4ω2+κ2/4)>0.W_q^>(-\omega)=\frac{\kappa}{2\omega\left(4\omega^2+\kappa^2/4\right)}>0.

    An exact zero-temperature Wightman spectrum for a stable ground state has no negative-frequency support. Here the oscillator state is exactly the vacuum of the effective Hamiltonian, but its two-time evolution is an already coarse-grained semigroup. The Lorentzian tail extrapolates that approximation outside its resolved positive-frequency line. At the peaks the ratio is κ2/(16ω2+κ2)\kappa^2/(16\omega^2+\kappa^2) and tends to zero as κ/ω→0\kappa/\omega\to0. An actual detector sampling an off-resonant microscopic bath needs the bath spectrum rather than this extrapolated line shape.

    References

    • L. M. Sieberer, M. Buchhold and S. Diehl, Keldysh Field Theory for Driven Open Quantum Systems, arXiv:1512.00637v2, §§ II.1–II.2.1, especially the doubled construction (19), loss action (42), inverse propagator (44), and spectral function (63). Their amplitude damping constant is half our occupation damping constant; the coherent-state construction assumes unbounded canonical bosons.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.