- Home
- Library
- Thermal and Nonequilibrium Field Theory
- Initial States and Schwinger–Keldysh Evolution
- KMS Symmetry and Real-Time Effective Actions
KMS Symmetry and Real-Time Effective Actions
Friction alone drives a particle to the bottom of a potential. Thermal noise continually excites it. Their coefficients must be related if the stationary distribution is to be the Gibbs distribution at a specified temperature. How does a real-time action know that relation?
For a quadratic theory, the quantum KMS condition fixes the noise kernel in terms of the dissipative response. In a classical low-frequency limit, this becomes a discrete transformation mixing time reversal with a shift of the response field. We will check that transformation directly, including the boundary term and initial distribution that make it an equilibrium statement.
Preparation: Thermal KMS and r/a propagators.
Exact KMS is a condition on the state
For a time-independent Hamiltonian and , cyclicity of the trace relates the two Wightman functions of a neutral Hermitian coordinate:
The shift is understood through the thermal correlation function's analytic continuation, not by assigning an imaginary time to a measured trajectory. With Fourier transform , the relation becomes . Hence, at nonzero frequency,
where , , and . Connected correlators are understood when the mean is nonzero. Conserved zero-frequency contributions require a separate static covariance. The damped oscillator below has no such atom.
KMS follows from thermality without requiring microscopic time reversal. Turning it into a transformation that maps a real-time generating functional back to the same theory uses an additional antiunitary symmetry . For example, ordinary time reversal suffices when and the thermal state are invariant and is even. Other systems can use a suitable combination with parity or charge conjugation. If an external magnetic field is present, time reversal generally relates the theory at that field to the theory at the reversed field. One cannot impose same-field time-reversal invariance merely because the state is thermal.
For a time-reversal-even scalar, a symmetric choice of thermal contour displacement has the formal branch transformation
The sources transform as well. This identity uses the thermal trace, its analytic continuation and compatible boundary conditions. It is not an additional assumption about arbitrary initial density matrices. Glorioso and Liu, §II.C and §III.B, derive the combined KMS/time-reversal identity and its family of contour displacements. In an interacting effective theory, the identity constrains higher vertices too; checking two-point FDT alone is not a proof of its full symmetry.
A Gaussian bath gives both kernels
Let a real coordinate couple through to independent oscillators of mass , frequency and force . Prepare the uncoupled bath in its Gibbs state. An oscillator obeys . Its commutator fixes the causal force response, while the thermal covariance fixes the force noise. Thus
At positive frequency put . Fourier transformation yields and there. The odd continuation of the first and even continuation of the second fix negative frequencies. The driven bath exerts in addition to its zero-mean fluctuating force. Bringing the induced force to the left side gives , where includes any local real spring counterterm. The two kernels below therefore have the dissipative sign fixed by this microscopic example. A continuum with at low positive frequency gives the Ohmic model. A discrete finite bath gives spectral lines and recurrences. Fleming, Roura and Hu, §II.A, Eqs. (2), (4)–(10) gives the oscillator realization with its local frequency counterterm. The finite-time influence functional retains the preparation and memory terms when those recurrences matter.
The quantum constraint on a quadratic action
Consider a stationary Gaussian effective theory for one real coordinate. Write its bulk action as
Here , , and the source is . The inverse physical response is ; and the noise spectrum is real, even and nonnegative. A Gaussian noise representation gives with .
After initial transients have decayed, and in the absence of undamped modes, this implies
The qualifier matters: a finite oscillator bath retains homogeneous initial-state contributions, so these stationary formulas cannot simply replace the initial-value solution with the finite-time Gaussian bath. In the contour convention , the mixed correlator remains .
Using , exact quantum FDT requires
This is the quadratic equilibrium constraint. It relates two independently allowed structures of a general open-system action. Causality and a positive imaginary part alone do not impose it.
For a response that is approximately Ohmic within its frequency range,
where and . The noise is even and nonnegative. At zero temperature it becomes and does not vanish. An actual bath supplies a high-frequency regulator and corresponding dispersive matching of the real kernel; extending this approximate Ohmic response to infinite frequency is not a microscopic model with finite quantum momentum fluctuations.
Taking the classical local limit
If throughout the frequencies retained in the effective description,
The leading noise is white. If bath memory is also short and is negligible relative to the retained terms, the resulting overdamped equation is
For the pole governing relaxation, dropping inertia requires . Bath locality, the classical approximation and the neglect of inertia are distinct conditions. They need not hold together.
The corresponding action is
Integrating over after introducing the Gaussian force gives the displayed Langevin equation. The linear additive-noise problem has a field-independent discretization Jacobian, which is absorbed in normalization. More general multiplicative noise or nonlinear effective theories require their own measure prescription; the displayed quadratic action does not silently specify one.
In a formal classical limit, restore in the imaginary displacement and scale the branch difference as . Expanding the exact branch transformation while keeping fixed leaves time reversed and shifts by a time derivative of . In the classical statistical action we continue to call the rescaled response variable . This explains why a local derivative appears: the exact quantum transformation contains thermal imaginary-time translations. Setting does not make the first derivative the exact quantum transformation at arbitrary frequency.
Checking the action and its boundary weight
Set the external sources to zero and use a finite interval . For real untransformed histories write and define
Here the dot on means the derivative of the original history with respect to . In particular, . Applying this transformation twice restores the original fields. The complex response-field shift is a change of variables in the Gaussian functional representation, not a complex physical displacement.
Let , and . Substituting into the transformed Lagrangian gives
The cross term from the noise is , and its term cancels the from friction. Using leaves
Thus
The bulk variation is a total derivative, not generally zero on a finite interval. In the path weight it contributes . The reversed trajectory starts at , so the Gibbs preparation cancels it:
This is the finite-interval equilibrium statement. On an infinite stationary contour, the corresponding preparation and boundary prescription are implicit. For an arbitrary initial probability distribution, the local bulk coefficients can satisfy the equilibrium relation while the full evolving state does not. Noise and response matching do not erase that initial information.
The cancellation also shows why the noise coefficient is fixed. Replace by . The same transformation then leaves additional bulk terms
These cannot be absorbed into the Gibbs endpoint weight for arbitrary histories. Equilibrium at the chosen temperature requires .
Response, fluctuations and detailed balance
The overdamped response and stationary spectrum are
The pole is in the lower half-plane. Fourier transformation gives
Therefore , the Gibbs variance. Equivalently, the Fokker–Planck equation is
The probability current vanishes for . This independently checks the noise factor of two.
More information is contained in the normalized transition probability. For elapsed time , let and . Solving the linear Langevin equation gives
Its forward-to-reversed ratio is
Multiplying by the corresponding initial Gibbs weights yields detailed balance. This calculation checks the endpoint sign without using the response-field transformation.
The companion in examples/thermal/schwinger-keldysh/influence-kms/ checks both representations. For , , , it substitutes smooth test histories into the action and integrates the total derivative, with a residual below . Halving the noise coefficient produces a residual for the same histories. The prescribed histories test the action identity directly. Independently, the exact transition kernel at , , gives a log probability ratio , agreeing with the Gibbs endpoint difference.
The quantum correction is also measurable. The ratio of Ohmic quantum noise to its white approximation is . It is at , but at . Matching white noise to friction at one temperature does not establish quantum KMS at the latter frequency.
Summary
Quantum KMS fixes a frequency-dependent relation between noise and response. A same-theory dynamical KMS transformation additionally uses an appropriate antiunitary symmetry. In the classical local Langevin limit, its response-field shift fixes the Einstein noise strength, while the action's boundary term matches the Gibbs preparation. Bulk coefficient matching, stationarity and the initial state must all be checked at the level appropriate to the problem.
Exercises
1. A stationary state at the wrong temperature
Keep the equation but replace the noise covariance by , with . Find its stationary distribution. Can it obey KMS at a specified temperature merely because it has no stationary probability current?
Solution
The Fokker–Planck equation now has diffusion coefficient . Vanishing stationary current requires , hence
The response is unchanged, but . It satisfies the classical FDT and detailed-balance identity at , not at the specified . In the action test at inverse temperature , produces the uncanceled bulk terms derived above. Absence of a stationary current identifies an equilibrium measure for this one-coordinate process; it does not identify its temperature independently of the fluctuations.
2. Restore the momentum
For with the same classical white noise, check the action transformation and identify the required endpoint weight. Obtain the stationary position and momentum variances, with .
Solution
The bulk action is . Under reversal, the velocity is odd and acceleration is even. The friction and noise terms cancel as before, while the extra variation is
Here the derivative is along the original history. Reversed endpoint data are and . The equilibrium boundary factor must include the full energy , not just the potential. It yields
An independent check uses the stochastic equations and . Stationarity of first gives . Stationarity of gives , and stationarity of then gives .
The frequency-space answer is . The companion checks its zeroth and moments against the stationary covariance obtained from a separate matrix Lyapunov equation. With and the parameters above, both methods give and . These are classical variances; replacing white noise by quantum noise changes the problem and requires its ultraviolet completion.
References
- P. Glorioso and H. Liu, Lectures on non-equilibrium effective field theories and fluctuating hydrodynamics, arXiv:1805.09331v1. §II.C, Eqs.(2.27)–(2.35), separates thermal trace cyclicity from the combined antiunitary identity. §III.B, Eqs.(3.10)–(3.12), gives the quantum transformation; §III.C, Eqs.(3.16)–(3.24), gives the Brownian action and noise–friction matching; §III.F, Eqs.(3.42)–(3.47), explains the classical transformation and total derivatives. Our explicit finite-interval calculation supplies its Gibbs endpoint factors.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.