Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    A temperature gradient can drive both charge and heat. If the circuit is open, the accumulating charge generates an electric field that changes the heat current. In a magnetic field, all of these currents can also turn sideways. We will calculate the coupled response of one relativistic fluid, distinguish the experimental constraints, and identify the circulating currents that must be removed before a microscopic Hall response is interpreted as transport.

    Preparation: Conductivity and momentum relaxation supplies the fluid and its slow momentum pole. Kubo formulas explains why the current operator and its source variations matter.

    Which forces and which currents?

    Let JiJ_i denote electric transport current and let JiE=T0iJ_i^E=T^{0i} denote energy transport current. At linear order about a state of temperature TT and chemical potential μ\mu, define heat current by

    Qi=JiE−μJi.Q_i=J_i^E-\mu J_i.

    The μ\mu in this expression is the reference equilibrium value. The subtracted term is the chemical energy transported with charge. We take unit charge normalization, so μ\mu is conjugate to the charge used in JJ and ρ\rho.

    Use the forces EiE_i and ζi=−∂iT/T\zeta_i=-\partial_iT/T. Here EE includes the electrochemical force Eelectromagnetic−∇μE_{\rm electromagnetic}-\nabla\mu if a chemical-potential gradient is present. Equivalently, keep ∇μ=0\nabla\mu=0 and use the applied electric field. The response convention is

    (JiQi)=(σijTαijTαˉijTκˉij)(Ejζj).\begin{pmatrix}J_i\\ Q_i\end{pmatrix} =\begin{pmatrix}\sigma_{ij}&T\alpha_{ij}\\T\bar\alpha_{ij}&T\bar\kappa_{ij}\end{pmatrix} \begin{pmatrix}E_j\\ \zeta_j\end{pmatrix}.

    Thus Q=−κˉ∇TQ=-\bar\kappa\nabla T at fixed E=0E=0, whereas J=−α∇TJ=-\alpha\nabla T under the same constraint. A bar on αˉ\bar\alpha distinguishes heat response to electric forcing from charge response to thermal forcing. A bar on κˉ\bar\kappa labels the fixed-field thermal coefficient. Neither bar means complex conjugation.

    For microscopic dynamics invariant under time reversal together with reversal of the external magnetic field, the transport coefficients obey

    σij(ω,B)=σji(ω,−B),αij(ω,B)=αˉji(ω,−B),κˉij(ω,B)=κˉji(ω,−B).\sigma_{ij}(\omega,B)=\sigma_{ji}(\omega,-B),\quad \alpha_{ij}(\omega,B)=\bar\alpha_{ji}(\omega,-B),\quad \bar\kappa_{ij}(\omega,B)=\bar\kappa_{ji}(\omega,-B).

    Other time-reversal-odd background parameters must also reverse. These Onsager relations compare the same frequency and do not insert complex conjugation; reality separately relates ω\omega to −ω-\omega. They do not in general identify α(B)\alpha(B) with αˉ(B)\bar\alpha(B). Their application to transport rather than arbitrary local currents is established in Cooper, Halperin and Ruzin, §II.E.

    Charge and heat at zero magnetic field

    Use a relativistic normal fluid in its Landau frame, with w=ε+p=Ts+μρw=\varepsilon+p=Ts+\mu\rho and weak isotropic momentum relaxation. Write dω=Γ−iωd_\omega=\Gamma-i\omega. The constitutive relation and momentum equation are

    J=ρv+σQ(E−μζ),wdωv=ρE+sTζ.J=\rho v+\sigma_Q(E-\mu\zeta),\qquad w d_\omega v=\rho E+sT\zeta.

    The thermal term in the dissipative current follows from −T∇(μ/T)=−∇μ+μ∇T/T-T\nabla(\mu/T)=-\nabla\mu+\mu\nabla T/T. The force sTζsT\zeta is the thermal part of −∇p-\nabla p, using dp=s dT+ρ dμdp=s\,dT+\rho\,d\mu. Energy current is wvwv, so

    Q=sTv−μσQ(E−μζ).Q=sTv-\mu\sigma_Q(E-\mu\zeta).

    These are the spatial equations underlying the transport calculation of Hartnoll, Kovtun, Müller and Sachdev, §III. Eliminating vv gives the 2×22\times2 matrix for one spatial direction:

    L(ω)=σQ(1−μ−μμ2)+1wdω(ρ2ρsTρsT(sT)2).L(\omega)=\sigma_Q\begin{pmatrix}1&-\mu\\-\mu&\mu^2\end{pmatrix} +\frac1{w d_\omega}\begin{pmatrix}\rho^2&\rho sT\\\rho sT&(sT)^2\end{pmatrix}.

    The first matrix describes the rest-frame dissipative current; the second describes convection. Both have rank one, but their vectors are independent because sT+μρ=w>0sT+\mu\rho=w>0. At zero field Tα=Tαˉ=L12T\alpha=T\bar\alpha=L_{12} and Tκˉ=L22T\bar\kappa=L_{22}.

    For real DC forces, the dissipated power density is

    EJ+ζQ=wΓv2+σQ(E−μζ)2≥0.EJ+\zeta Q=w\Gamma v^2+\sigma_Q(E-\mu\zeta)^2\geq0.

    Dividing by TT gives the entropy production rate. This checks the minus sign in the regular thermoelectric coefficient: Tαreg=−μσQT\alpha_{\rm reg}=-\mu\sigma_Q. Positivity constrains the complete matrix, not the sign of each off-diagonal entry.

    Opening the circuit changes the thermal conductivity

    For an open circuit, impose J=0J=0 and solve for the compensating field:

    E=−Tσ−1αζ=σ−1α∇T.E=-T\sigma^{-1}\alpha\zeta=\sigma^{-1}\alpha\nabla T.

    With the stated voltage convention the Seebeck tensor is S=σ−1αS=\sigma^{-1}\alpha. Substitution into the heat current gives

    κ=κˉ−Tαˉσ−1α,Q=−κ∇T(J=0).\kappa=\bar\kappa-T\bar\alpha\sigma^{-1}\alpha,\qquad Q=-\kappa\nabla T\quad(J=0).

    The order of the matrix factors matters for an anisotropic or Hall system. At B=0B=0, direct evaluation gives

    det⁡LDC=σQwΓ,κDC=σQw2T(ρ2+σQwΓ).\det L_{\rm DC}=\frac{\sigma_Qw}{\Gamma},\qquad \kappa_{\rm DC}=\frac{\sigma_Q w^2}{T(\rho^2+\sigma_Qw\Gamma)}.

    The determinant follows by multiplying the two rank-one contributions: their two vectors have determinant sT+μρ=wsT+\mu\rho=w. It is also a useful check on every factor of TT in the force convention.

    For the shared example T=1T=1, μ=0.4\mu=0.4, ρ=0.7\rho=0.7, w=2.3w=2.3, s=2.02s=2.02, σQ=0.35\sigma_Q=0.35 and Γ=0.12\Gamma=0.12, the results are:

    CoefficientDC valueConstraint or definition
    σ\sigma2.125362322.12536232ζ=0\zeta=0
    α=αˉ\alpha=\bar\alpha4.983188414.98318841Matrix cross coefficient
    κˉ\bar\kappa14.8400579714.84005797E=0E=0
    κ\kappa3.156324583.15632458J=0J=0
    SS2.344630072.34463007E=S∇TE=S\nabla T at J=0J=0

    In the clean limit at nonzero ρ\rho, κˉ\bar\kappa diverges but κ\kappa tends to σQw2/(Tρ2)=3.77857143\sigma_Qw^2/(T\rho^2)=3.77857143. The electric field required to stop charge convection also removes its divergent heat flow. This cancellation does not hold at ρ=0\rho=0: there charge current cannot cancel a neutral momentum-carrying heat current.

    A planar magnetic-field calculation

    Take the fluid in the xyxy plane, with BB pointing along +z+z, and fix

    ϵ=(01−10),ϵxy=+1,ϵ2=−1.\epsilon=\begin{pmatrix}0&1\\-1&0\end{pmatrix},\qquad \epsilon_{xy}=+1,\qquad \epsilon^2=-\mathbf1.

    Then v×B=Bϵvv\times B=B\epsilon v. A positive σxy\sigma_{xy} means that an electric field along +x+x gives a negative Hall current JyJ_y. This declaration fixes the spatial sign independently of any retarded-correlator convention.

    Retain the leading hydrodynamic constitutive equations

    J=ρv+σQ(E+Bϵv−μζ),wdωv=ρE+sTζ+BϵJ,Q=wv−μJ.J=\rho v+\sigma_Q(E+B\epsilon v-\mu\zeta),\qquad w d_\omega v=\rho E+sT\zeta+B\epsilon J,\qquad Q=wv-\mu J.

    We assume Γ\Gamma, ∣ω∣|\omega|, ∣ρB∣/w|\rho B|/w and σQB2/w\sigma_QB^2/w are small compared with the microscopic equilibration rate. Thermodynamic coefficients are taken at zero field at this order; strong-field Landau quantization, intrinsic parity-odd transport and higher-gradient corrections are outside this example. Retaining the B2B^2 term generated by these leading equations is necessary to keep the dissipative damping of their cyclotron mode.

    Define three spatial matrices:

    A=(wdω+σQB2)1−ρBϵ,R=ρ1+σQBϵ,S0=sT1−μσQBϵ.A=(w d_\omega+\sigma_QB^2)\mathbf1-\rho B\epsilon,\qquad R=\rho\mathbf1+\sigma_QB\epsilon,\qquad S_0=sT\mathbf1-\mu\sigma_QB\epsilon.

    The velocity solves Av=RE+S0ζAv=RE+S_0\zeta. If a=wdω+σQB2a=w d_\omega+\sigma_QB^2 and b=ρBb=\rho B, then

    A−1=a1+bϵa2+b2.A^{-1}=\frac{a\mathbf1+b\epsilon}{a^2+b^2}.

    All transport blocks follow without a long list of component fractions:

    σ=σQ1+RA−1R,Tα=−μσQ1+RA−1S0,Tαˉ=−μσQ1+S0A−1R,Tκˉ=μ2σQ1+S0A−1S0.\begin{aligned} \sigma&=\sigma_Q\mathbf1+RA^{-1}R,\\ T\alpha&=-\mu\sigma_Q\mathbf1+RA^{-1}S_0,\\ T\bar\alpha&=-\mu\sigma_Q\mathbf1+S_0A^{-1}R,\\ T\bar\kappa&=\mu^2\sigma_Q\mathbf1+S_0A^{-1}S_0. \end{aligned}

    The heat blocks use w1−μR=S0w\mathbf1-\mu R=S_0. In this isotropic model the matrices commute, so α(B)=αˉ(B)\alpha(B)=\bar\alpha(B). More generally that equality need not hold. Here A(B)T=A(−B)A(B)^T=A(-B), and the same identity holds for RR and S0S_0; transposing each block explicitly verifies Onsager reversal.

    The cyclotron poles are

    ω=±ρBw−i(Γ+σQB2w).\omega=\pm\frac{\rho B}{w}-i\left(\Gamma+\frac{\sigma_QB^2}{w}\right).

    The extra damping arises because fluid motion induces a rest-frame electric field and hence a dissipative current. Its sign can also be checked in DC:

    E⋅J+ζ⋅Q=wΓ∣v∣2+σQ∣E+Bϵv−μζ∣2.E\cdot J+\zeta\cdot Q=w\Gamma|v|^2+\sigma_Q|E+B\epsilon v-\mu\zeta|^2.

    To derive this, dot the momentum equation with vv. The Lorentz term containing ρv\rho v does no work; its term containing the rest-frame current combines with (E−μζ)⋅(J−ρv)(E-\mu\zeta)\cdot(J-\rho v) into the square. An incorrect Hall sign generally spoils this cancellation.

    For B=0.2B=0.2 and the same fluid parameters, the DC components are:

    Tensorxxxx componentxyxy component
    σ\sigma1.574291221.574291220.928968180.92896818
    α=αˉ\alpha=\bar\alpha3.655336553.655336552.252231442.25223144
    κˉ\bar\kappa11.6174796511.617479655.191335005.19133500
    κ\kappa3.134453523.13445352−0.26182786-0.26182786

    The open-circuit thermal Hall sign differs from the fixed-field sign. This follows directly by imposing J=0J=0 before eliminating vv:

    [(ρ2+σQwΓ)1+σQρBϵ]v=σQwζ.\bigl[(\rho^2+\sigma_Qw\Gamma)\mathbf1+\sigma_Q\rho B\epsilon\bigr]v=\sigma_Qw\zeta.

    Since Q=wvQ=wv in an open circuit, inversion gives

    κ=σQw2T (ρ2+σQwΓ)1−σQρBϵ(ρ2+σQwΓ)2+(σQρB)2.\kappa=\frac{\sigma_Qw^2}{T}\, \frac{(\rho^2+\sigma_Qw\Gamma)\mathbf1-\sigma_Q\rho B\epsilon}{(\rho^2+\sigma_Qw\Gamma)^2+(\sigma_Q\rho B)^2}.

    The companion in examples/thermal/linear-response/momentum-heat-memory/ evolves the driven velocity equations and extracts all four blocks at ω=0.17\omega=0.17 and 0.430.43. The largest discrepancy from matrix inversion is 3.1×10−133.1\times10^{-13}. Field reversal and the entropy identity also pass.

    Removing currents that only circulate

    A local current in a magnetic material can include equilibrium circulation. For slowly varying states in a planar sample, at vanishing probe sources, write

    Jlocal=Jtr+∇×(Mz^),JlocalE=JtrE+∇×(MEz^).J_{\rm local}=J_{\rm tr}+\nabla\times(M\hat z),\qquad J^E_{\rm local}=J^E_{\rm tr}+\nabla\times(M_E\hat z).

    Here MM is charge magnetization in the chosen current normalization and MEM_E is energy magnetization. Their curls describe bulk pieces of currents that close through sample boundaries. They can be locally nonzero without transferring net charge or heat between reservoirs. The J,QJ,Q in our hydrodynamic calculation are transport currents, with these contributions removed.

    For a temperature gradient along xx at fixed μ\mu and BB, the bulk circulating pieces include

    Jmag,y=−(∂M∂T)μ,B∂xT,Qmag,y=−[(∂ME∂T)μ,B−μ(∂M∂T)μ,B]∂xT.J_{{\rm mag},y}=-\left(\frac{\partial M}{\partial T}\right)_{\mu,B}\partial_xT,\qquad Q_{{\rm mag},y}=-\left[\left(\frac{\partial M_E}{\partial T}\right)_{\mu,B}-\mu\left(\frac{\partial M}{\partial T}\right)_{\mu,B}\right]\partial_xT.

    They resemble thermal Hall response locally. With varying chemical potential or auxiliary gravitational sources, further terms accompany these expressions; one cannot universally subtract just the curl of ME−μMM_E-\mu M.

    A microscopic calculation needs M(T,μ,B)M(T,\mu,B) and ME(T,μ,B)M_E(T,\mu,B) in the correlators' source and current conventions. Charge magnetization follows from the equilibrium free-energy response to magnetic flux; energy magnetization requires a stationary energy-current or metric source. Include source-dependent current variations and boundary terms. The fluid parameters above do not supply these microscopic data.

    This matters especially for a thermal Kubo calculation using a Luttinger gravitational potential: the source changes the current operator itself as well as the state. Cooper, Halperin and Ruzin, Eqs. (48)–(49) and (58)–(72) derive the separation and its Onsager properties. Hartnoll and collaborators, Eqs. (5.20)–(5.21) give an explicit equilibrium-source definition of both magnetizations. A raw heat-current correlator alone is therefore insufficient to identify measured Hall transport.

    Summary

    The charge–heat matrix depends on the chosen forces. Opening the circuit gives a matrix subtraction that can change the magnitude and sign of thermal response. Onsager reciprocity reverses the magnetic field and exchanges the cross responses. Microscopic Hall calculations require transport currents with equilibrium circulation and source contacts treated consistently.

    Exercises

    1. Neutral heat flow and the order of limits

    At B=0B=0, set ρ=μ=0\rho=\mu=0 and hold w=Ts>0w=Ts>0, σQ>0\sigma_Q>0. Find σ\sigma, α\alpha and κ\kappa at DC. Explain why the clean-limit result at nonzero charge cannot simply be evaluated at ρ=0\rho=0.

    Solution

    The electric current is J=σQEJ=\sigma_QE and has no momentum overlap. The heat current is Q=wvQ=wv, while wΓv=sTζ=wζw\Gamma v=sT\zeta=w\zeta. Hence

    σ=σQ,α=αˉ=0,κ=κˉ=wTΓ.\sigma=\sigma_Q,\qquad \alpha=\bar\alpha=0,\qquad \kappa=\bar\kappa=\frac{w}{T\Gamma}.

    At any positive Γ\Gamma, this also follows from the general expression for κ\kappa. Its neutral limit diverges as Γ→0\Gamma\to0: a temperature gradient accelerates momentum and therefore heat. The nonzero-density clean expression σQw2/(Tρ2)\sigma_Qw^2/(T\rho^2) was obtained by dropping σQwΓ\sigma_Qw\Gamma relative to ρ2\rho^2. That approximation is not uniform as ρ→0\rho\to0. Their crossover is controlled by ρ2/(σQwΓ)\rho^2/(\sigma_Qw\Gamma), not by the label “clean” alone.

    2. A Hall voltage without transverse entropy production

    Set σQ=0\sigma_Q=0, keep ρ≠0\rho\ne0 and Γ>0\Gamma>0, and apply no thermal gradient. Find the resistivity tensor. Then find the heat conductivity under the open-circuit condition. Why does a Hall voltage not by itself dissipate energy?

    Solution

    Now J=ρvJ=\rho v. Substituting into the stationary momentum equation gives

    E=(wΓρ21−Bρϵ)J.E=\left(\frac{w\Gamma}{\rho^2}\mathbf1-\frac{B}{\rho}\epsilon\right)J.

    The antisymmetric Hall resistivity contributes nothing to E⋅JE\cdot J because J⋅ϵJ=0J\cdot\epsilon J=0. The longitudinal contribution is wΓ∣J∣2/ρ2w\Gamma|J|^2/\rho^2, equal to the mechanical momentum-loss power. In an open circuit J=0J=0 forces v=0v=0, so Q=wv−μJ=0Q=wv-\mu J=0 and κ=0\kappa=0. A compensating field E=−(sT/ρ)ζE=-(sT/\rho)\zeta balances the thermal force. Thus finite fixed-field heat convection and Hall response need not imply an independent channel for heat transport at zero charge current.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.