- Home
- Library
- Lattice and Hamiltonian Field Theory
- Measuring a Spectrum from Correlators
- Effective Masses and Correlated Fits
Effective Masses and Correlated Fits
A Euclidean correlator falls exponentially, but its points fluctuate together. Which decay rate is a physical energy, and which is an artifact of the time window or fit model? We derive two effective-energy estimators, fit an explicitly synthetic two-state sample, and then analyze an actual interacting scalar ensemble against its independently diagonalized transfer operator. The first scalar gap is resolved; a two-state fit to its elementary field alone does not resolve the next level.
Preparation: Finite-time spectral decompositions and errors in correlated Monte Carlo data. Times and energies below are in lattice units, so the reported energy is .
From a decay curve to an effective energy
Let for a zero-momentum operator. In a vacuum spectral representation with the same operator at source and sink,
where are gaps above the vacuum. If one term dominates, the adjacent ratio gives
For two forward terms, put and . Direct substitution gives
Thus positive excited-state weight raises this estimator above . A mixed source–sink correlator can have signed weights and need not approach from above. A correlated fluctuation can also resemble a plateau; this is one reason to inspect several windows rather than choose the flattest-looking one. See Gupta, §18, printed pp.115–119 (PDF).
A periodic temporal lattice of circumference changes even the one-state formula. The vacuum–state pair contributes
Its recurrence is , so
returns exactly for . The adjacent logarithm instead turns down near . A measured ratio below one in the arcosh argument is an undefined real estimator, not a value to replace by zero. Even above one, amplifies noise near . Evaluate the nonlinear estimator on resampled mean correlators, not by averaging effective energies of individual configurations.
The cosh formula corrects backward propagation, but does not remove general thermal transitions. For Hermitian , the exact finite- trace is
Here runs over the entire Hilbert spectrum, with the vacuum energy set to zero. The terms with one state equal to the vacuum form the familiar cosh pairs. Terms with both states excited survive at finite and contain energy differences other than vacuum gaps. A sum of a few vacuum coshes is therefore a model to test, not an identity for an interacting thermal correlator.
Fit the correlator and its covariance together
Suppose approximately independent blocks provide complete time vectors . Their mean and estimated covariance of the mean are
The factor distinguishing the covariance of the mean from the covariance of individual blocks is essential. All times from one configuration belong in the same block. Increasing the number of time origins reduces noise, but does not turn those origins into independent configurations.
For a model , minimize
If is a Cholesky factorization, solve with the whitened residual rather than explicitly invert the matrix. For one cosh and a fixed trial energy, the amplitude has the analytic optimum
Only a one-dimensional energy minimization remains. The two-state model has four parameters, . Here positivity and ordering are imposed through . This positivity is appropriate for this diagonal correlator model; it is not a constraint on every off-diagonal matrix element.
Small covariance eigenvalues give large weights to corresponding residuals. A poorly estimated small eigenvalue can dominate a fit. Merely retaining more times can therefore make inference worse. Covariance modeling, shrinkage, or a declared singular-value cut changes the weighting procedure and needs its own sensitivity analysis. We use the full positive covariance without a cut here. Michael and McKerrell, §§1–2, printed pp.1–3 (PDF) explain the finite-sample covariance problem.
For uncertainty, remove block , form , and repeat the complete fit. If are the results,
Our refits hold the full-sample covariance fixed. These errors describe fluctuations under that weighting choice and local fit solution; they do not include uncertainty from re-estimating the weights, choosing a window, or selecting a model. We report and the nominal number of degrees of freedom as diagnostics, without assigning exact chi-square probabilities to noisy-covariance, nonlinear, or boundary fits.
A synthetic sample with two known energies
This test is deliberately synthetic, not a field ensemble. At and , define
The scaled autoregressive covariance is positive definite. The vectors are independent in , correlated across , and may contain negative entries. No entries are clipped. NumPy's PCG64 generator uses SeedSequence([771025, 10]) once; the complete vectors are retained by the companion.
Before generating them, we fixed , , and both one- and two-state models. One-state energies lie in . Two-state bounds are , , and . Nine deterministic starts combine and gaps , initially with amplitudes . The lowest converged objective is selected, and all start outcomes are saved. Delete-one-vector fits start from that full-sample solution; they are a local uncertainty check, not a search for every possible nonlinear minimum.
Using the sample-estimated covariance gives the following energies; each uncertainty is one jackknife standard error.
| Window | One-state energy | Two-state | Two-state |
|---|---|---|---|
The early two-state fit differs from the input energies by about standard errors for and for . The early one-state result is precise and wrong: its is for nominal degrees of freedom, versus for two states. By , the one-state fit has and the expected lowest energy, while the second energy is weakly determined. The large late-window symmetric jackknife errors should not be mistaken for well-calibrated Gaussian confidence intervals on such a nonlinear parameter.
The known covariance provides a separate weighting check: the early two-state fit gives and . Using the estimated covariance gives consistent energies for this sample. The whitened two-state Jacobian condition number rises from about at to about at : discarding the early excited-state signal leaves poorly distinguished parameter combinations.
An actual interacting scalar correlator
Now use a different calculation: a periodic two-dimensional Euclidean scalar lattice with , , unit spacings, , and . Its action is
There are two forward spatial bonds on the periodic two-site slice. Define and measure
The exact reflection symmetry makes ; we do not subtract a noisy estimated mean. Sixteen independently seeded Gaussian-proposal Metropolis chains retain every post-sweep field, including rejected proposals, after warmup sweeps and for further sweeps each. Seeds are SeedSequence([771025, 0, replica]); eight chains start at zero and eight at the constant field . The finite-time article specifies the matching finite-step transfer operator and its numerical refinements.
Aligned blocks of sweeps give vectors for the primary analysis. Block lengths and , first and second retained halves, and the two starting groups are also retained checks. For example, the standard error of is , , and for these three block lengths. This stability supports the chosen error scale; it is not proof against correlations longer than all tested blocks. The shared diagnostics retain starting-group differences of about combined replica errors in and , with ; the relevant correlator groups are closer. Finite replica counts also make the error estimates fluctuate.
The four predeclared one-cosh windows give:
| Window | Fitted energy | |
|---|---|---|
Direct diagonalization gives the lowest odd-, even- gap . Fitting its full thermal correlator with the same weights gives , a model shift of about , much smaller than the sampled uncertainty. This is a check in the specified finite lattice and finite time step; neither a continuum extrapolation nor an infinite-volume particle-mass determination has been made.
For that same window, the zero-start and hot-start groups give and ; the first and second retained halves give and . Changing the block length from to changes the full-sample energy standard error from to . These finite checks reveal the size of the sampling fluctuations without selecting a more favorable subset.
The elementary operator hardly couples to the second channel level: its first two vacuum amplitudes are approximately and . Their squared ratio is about . Consequently, the two-state fit gives , which does not resolve the direct value . The fit reaches the imposed upper gap bound in the full fit and all refits; no jackknife error is reported. A small objective does not supply missing information. The correlation-matrix method introduces operators with larger second-level overlap.
The figure keeps the two data sources separate. Its lower-left panel shows why backward propagation must be handled even when the first gap is clean.
Top: the independent synthetic Gaussian vectors at , with input energies and . Bottom: the actual interacting scalar ensemble. The adjacent logarithm is plotted at the interval midpoint; the cosh estimator uses the central time. Bars are fixed-weight jackknife standard errors, using complete synthetic vectors above and -sweep blocks below. They omit model and window uncertainty.
A useful separate free-field check already exists in statistical errors: on the periodic , free lattice, the actual heat-bath fit yields , compared with . That earlier ensemble has a different action and circumference; it is not combined with either dataset above.
The reproducible companions are examples/lattice-hamiltonian/spectroscopy/fit_correlators.py, fit-results.json, and plot_fits.py. The analysis consumes the shared scalar histories and retains all selected windows, covariance spectra, start outcomes, undefined estimates and boundary fits. Noiseless one- and two-cosh recovery and the exact cosh recurrence test the fitting and estimator implementations independently of the production sample.
For a calculation in physical units, use the reference observable to set the spacing and apply this correlated fit across eight periodic scalar ensembles. Fit-window stability tests the time dependence. Changing the spacing or box probes additional effects.
Summary
Effective energies expose time dependence but inherit strong correlations and nonlinear noise. A correlated fit uses the covariance of complete time vectors; a credible energy also needs window, model, sampling and finite-time checks. The synthetic control distinguishes one-state bias from loss of excited-state information. The actual scalar example resolves the first finite-lattice gap, while the weakly coupled second level requires a richer operator basis.
Exercises
1. A downturn without an excited state
For with , derive the exact adjacent logarithmic energy and show that it lies below . Explain why the cosh estimator avoids this bias.
Solution
Factor out and set . Since ,
Well before the midpoint, the correction is
For even , the last interval before the midpoint has , still below . The cosh recurrence uses both neighboring times and includes both propagation directions exactly, so it returns wherever its three points exist. Neither argument removes additional states or thermal transitions.
2. Why correlated errors can make a ratio more precise
Two positive mean measurements have means , variances , and covariance . Derive the leading variance of . Then take , , where is independent of the additive noises, and show what happens to the common multiplicative fluctuation.
Solution
Linear propagation gives , hence
The common fluctuation contributes to each of the first two terms and twice that amount to the subtraction. It cancels, leaving
With no additive noise the cancellation is exact, since whenever the ratio is defined. Dropping off-diagonal covariance would miss this cancellation. This does not imply that correlations always reduce errors: the signs of the derivatives and covariances determine the result, and the linear approximation fails near nonpositive noisy means.
References
- Rajan Gupta, Introduction to Lattice QCD, arXiv:hep-lat/9807028 (1998), §18, printed pp.115–119. Open lecture notes (PDF).
- C. Michael and A. McKerrell, “Fitting correlated hadron mass spectrum data,” Physical Review D 51, 3745–3750 (1995), especially §§1–2 of the preprint. DOI; open preprint (PDF).
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.