- Home
- Library
- Lattice and Hamiltonian Field Theory
- Currents, Matrix Elements, and Operator Matching
- Momentum-Subtraction Schemes for Lattice Operators
Momentum-Subtraction Schemes for Lattice Operators
A bare lattice matrix element is tied to its regulator. Momentum-subtraction schemes define an operator by demanding a prescribed value for a projected off-shell vertex at a chosen scale. This can be imposed nonperturbatively on gauge configurations; conversion to a continuum scheme is a separate calculation.
We develop the projection and amputation carefully, test their normalization with exact Wilson symbols, and compute genuine interacting bilinear ratios in the finite Wilson square. That square has its own declared finite-volume scheme. The finite-volume example isolates the normalization step.
Preparation: Quark contractions, current normalization and Ward identities, and operator renormalization. Momenta below are Euclidean, so a subtraction point has .
Define the Green function before its projector
Consider a flavor-nonsinglet bilinear with degenerate quark masses. Fix a gauge prescription, usually Landau gauge for standard RI/MOM applications. Let be the gauge-averaged bare propagator and the gauge-averaged nonamputated insertion between incoming momentum and outgoing momentum . Define
The averaging precedes amputation. On a fixed background, the contraction contains two propagators with the same gauge field; their gauge average does not factor into averaged propagators. Amputating each configuration before averaging generally removes the vertex information one intended to measure.
We use the usual NPR field notation
Here relative to the global field convention, which writes . This reciprocal relation is a notation translation, not a change of the site convention.
Choose a linear projector normalized by . For multiplicative renormalization, a subtraction condition is
The mass limit defines a mass-independent scheme. It must be implemented with any required pole subtraction and critical-mass tuning; setting the Wilson bare mass to zero is not generally the same operation. If operators mix, several independent projectors are required and this scalar equation becomes a matrix condition. The defining construction is in Martinelli et al., §2, Eqs. (2)–(7), printed pp. 5–6; the field and vertex relations are also explicit in Sturm et al., §2, Eqs. (1)–(8), printed pp. 4–5.
For three colors and four spin components, scalar and pseudoscalar examples are
We take Hermitian Euclidean and , as in the lattice-fermion chapter. Since , the pseudoscalar projector gives 1 at tree level. A fixed vector component uses without summing ; an average over all four components uses a factor . Stating the trace and sum conventions prevents an unnoticed factor 4 or minus sign.
Exceptional and symmetric subtraction points
At the exceptional RI/MOM vertex point,
An insertion then carries zero momentum, allowing soft propagation in that channel even when the external quark virtuality is large. In channels affected by spontaneous chiral symmetry breaking, such as the pseudoscalar, this can produce strong infrared contamination and a chiral pole. Its treatment belongs to the mass extrapolation and subtraction procedure.
A symmetric nonexceptional choice is
For example, and satisfy all three conditions. They also arise from integer four-dimensional momenta after choosing the common magnitude. Nonexceptional kinematics suppress the soft channel; they do not abolish every power correction or lattice artifact. Sturm et al., §1, printed pp. 1–3 explains this motivation and the distinction from the exceptional point.
Kinematics alone do not specify the entire scheme. The field normalization and vertex projectors also matter. In continuum Euclidean notation, write . Two familiar field conditions are
These derivative and slash-momentum definitions need not agree beyond their appropriate tree limits. RI/SMOM uses a compatible set of nonexceptional conditions tied to the Ward identities. For example, with the Euclidean conserved-vector identity , a natural symmetric vector projector is
Its tree value is 1. One cannot exchange it for an arbitrary component projector while retaining all conversion factors of the original scheme. On a lattice the exact conserved current and its lattice momentum factors must be used in the discrete Ward identity; the local vertex alone omits Wilson terms.
Exact free checks expose ultraviolet kinematics
For Wilson parameter , the free Euclidean symbol is
The companion constructs explicit four-dimensional gamma matrices and three identical color blocks. For both exceptional and symmetric momenta it forms , amputates, and checks every scalar, fixed-vector and pseudoscalar tree projector. All return 1 to rounding error. Using instead of its adjoint in the pseudoscalar projector deliberately returns .
At finite , a commonly used tree-normalized slash condition employs :
Using continuum in the same projection instead gives
The Wilson scalar term drops out of the gamma trace. At the same , an axis momentum gives , while the four-dimensional diagonal gives . Thus orientation dependence appears before any interaction. The frozen test uses . The sine-momentum projection remains 1, while the continuum-momentum values at are about and for the axis and diagonal directions. Choosing improved kinematics does not remove every interacting cutoff artifact.
A usable QCD subtraction window requires infrared scales and finite-volume effects to be small compared with , while is small enough for cutoff control. Its existence must be checked with several masses, orientations, volumes and spacings. The free calculation has no QCD condensate or Goldstone pole, so it cannot measure infrared contamination.
To display the competing trends without inventing gauge data, consider the separately synthetic, deterministic curve
in fixed inverse-energy and energy units. Both terms are prescribed, not fitted. Requiring each to be below gives . This illustrates a window criterion; it supplies no nonperturbative QCD result.
Left: exact free four-dimensional Wilson-symbol projections at fixed momentum magnitude, comparing axis and diagonal directions with the sine-momentum normalization. Right: the explicitly synthetic and its prescribed infrared and cutoff terms. The shaded interval has each term below ; it is not a window measured in a QCD ensemble.
A genuine interacting finite-volume bilinear calculation
We can test nonperturbative averaging and normalization on a small interacting lattice. Use the complete open Wilson square at , , , with two sea flavors. Its Dirac matrix has diagonal , forward blocks and reverse blocks . Outside fermion values vanish. Fix the three-link tree so that only the right temporal link is , and integrate with weight
All averages are deterministic quadratures of this interacting gauge measure. The finite scheme uses full-site amputation; it is not a Fourier transform or an RI/MOM point.
Let project onto the four spin components on the lower time slice, be the conserved time-cut insertion, and . The shared current calculation gives
and defines
The conserved current has , so its renormalized projection is 1. A source on the lower slice and sink on the upper slice have ; their exact source–sink Ward ratio remains 1 when both Green functions acquire the same field factor. This transports a finite-grid charge identity through the declared scheme. It is not an isolated hadronic matrix element on two time slices, and its factor does not apply to the separate charged-ring form-factor model.
For a flavor-nonsinglet scalar or pseudoscalar, set and calculate
Here or , with . The factor normalizes the spin trace; unlike the temporal current insertion, these bilinears do not contain an extra factor in .
| Bilinear | Bare projected vertex | Finite-volume factor |
|---|---|---|
| Scalar | ||
| Pseudoscalar |
Multiplication by makes each projected vertex 1. Amputating before averaging would incorrectly leave the bare insertion and hence projection 1 even before this step. Periodic quadrature at nodes and independent 64-node Gauss–Legendre quadrature agree within for these factors.
The prescription is explicitly mass-dependent and gauge-dependent. Moving the flux to the upper spatial link by the gauge transformation with site phases defines a different tree-gauge prescription. With the same projector rule, the scalar and pseudoscalar factors become and . This is a useful limitation check, not a choice between a correct and incorrect gauge-invariant observable. Neither prescription is standard Landau-gauge RI/MOM. Moreover, one projected normalization does not make the entire local-current vertex equal to the conserved one; the current companion retains that nonzero matrix discrepancy.
Conversion is another calculation
For a multiplicatively renormalized operator in a genuine continuum RI scheme, write
The finite conversion must be computed with the same gauge, external kinematics, projector and chiral conventions at a stated perturbative order. Its truncation error differs from lattice-spacing, finite-volume, mass-extrapolation and statistical errors. Operator mixing makes a matrix and requires consistent transformation of Wilson coefficients. The finite square above has no supplied QCD conversion; attaching a known QCD factor to it would not create an matrix element.
The companions examples/lattice-hamiltonian/matrix-elements/momentum_subtraction.py, momentum-results.json and plot_momentum.py retain the free spin-color tests, the actual finite-square scalar and pseudoscalar ratios, gauge and quadrature comparisons, and the separately labeled synthetic curve. The shared currents.py supplies the finite-volume Ward construction. Finite-volume step scaling explains how a defined scheme can reach higher scales through controlled continuum steps.
Summary
A momentum-subtraction scheme fixes a projected vertex after gauge averaging and amputation, with a specified field normalization, mass limit and external kinematics. Exact free checks reveal projector and lattice-momentum errors; an actual finite-square example demonstrates a nonperturbative ratio without supplying a QCD momentum window. Continuum conversion and physical matrix-element normalization remain separately specified steps.
Exercises
1. Normalize a pseudoscalar and an averaged vector projector
For three colors and four spin components, let with . Find a projector with tree value 1. Find the normalization for an average of all four vector components, and explain the two errors caused by using the wrong prefactors.
Solution
The pseudoscalar projector is . At tree level, the two phases multiply to and . Using in the projector instead gives and would produce an erroneous sign in the inferred factor.
For a vector average, use
Each tree trace is 12, so the sum is 48. Keeping while summing would give 4; is appropriate for one fixed component. A tree normalization check therefore detects both errors before any gauge data are analyzed.
2. When does the synthetic window exist?
For with positive coefficients, require each term to be below . Derive the allowed interval, its existence condition, and the momentum that minimizes the total contamination.
Solution
The infrared condition gives ; the cutoff condition gives . A nonempty interval therefore requires
Differentiating the total contamination gives
For the declared parameters and , the interval is approximately , , and the minimum is about . Refining broadens the allowed interval and lowers the minimum. These conclusions follow from the chosen synthetic powers; their coefficients and even their applicable form must be established separately in a real calculation.
References
- G. Martinelli, C. Pittori, C. T. Sachrajda, M. Testa and A. Vladikas, “A General Method for Non-Perturbative Renormalization of Lattice Operators,” Nuclear Physics B 445 (1995) 81–108; §2, Eqs. (2)–(7), and the derivative versus sine-momentum field definitions in Eqs. (29)–(30). Open manuscript, arXiv:hep-lat/9411010 (PDF).
- C. Sturm, Y. Aoki, N. H. Christ, T. Izubuchi, C. T. Sachrajda and A. Soni, “Renormalization of quark bilinear operators in a momentum-subtraction scheme with a nonexceptional subtraction point,” Physical Review D 80 (2009) 014501; §§1–2, especially Eqs. (1)–(9), and Appendix A on alternative projectors. Open manuscript, arXiv:0901.2599v2 (PDF).
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.