Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Static Potentials and Flux Tubes

    How much energy does it cost to hold two gauge charges a fixed distance apart? A rectangular Wilson loop answers through its decay in Euclidean time. The calculation requires two decisions: which state the loop creates, and how to separate that state's lowest energy from noise and excited-state contamination.

    We will derive the extraction, then carry it out on actual open-boundary compact-U(1)U(1) configurations in two Euclidean dimensions. This model has an exact loop expectation, so it tests link products, correlated fitting and potential differences without confusing sampling errors with an unknown answer. Its simplicity also exposes what it cannot test: transverse flux structure and excited flux-state contamination.

    Preparation: compact links and Haar integration, the Wilson action, and the transfer-matrix interpretation. Write spatial separation as R=rasR=r a_s and Euclidean time as T=taτT=t a_\tau, where r,tr,t are positive integers.

    A loop propagates a pair of static sources

    Use forward transporters with endpoint law

    Vμ(x)↦G(x+μ^)Vμ(x)G†(x).V_\mu(x)\mapsto G(x+\hat\mu)V_\mu(x)G^\dagger(x).

    A path acts on a vector at its initial site, so the last traversed link multiplies on the left. Closing the path and tracing removes its remaining endpoint transformation. In a representation of dimension dRd_R, define

    W(r,t)=⟨1dRtr⁡RU□(r,t)⟩.W(r,t)=\left\langle \frac{1}{d_R}\operatorname{tr}_R U_{\square(r,t)} \right\rangle.

    The two time-like sides propagate the static charges; the spatial sides create and annihilate a chosen gauge-field state between them. For a reflection-positive action with vacuum projection outside the rectangle, insert energy eigenstates in the sector containing those sources:

    W(r,t)=∑n∣cn(r)∣2e−[En(R)−Evac] taτ.W(r,t)=\sum_n |c_n(r)|^2 e^{-[E_n(R)-E_{\rm vac}]\,t a_\tau}.

    The static potential is the source sector's ground-state energy difference. A loop with nonzero ground-state overlap extracts it through

    V0(R)=E0(R)−Evac,aτVeff(r,t)=log⁡W(r,t)W(r,t+1).V_0(R)=E_0(R)-E_{\rm vac},\qquad a_\tau V_{\rm eff}(r,t)=\log\frac{W(r,t)}{W(r,t+1)}.

    If c0=0c_0=0, waiting longer does not recover V0V_0 in this channel. If c0c_0 is small, the required waiting time can exceed the useful signal range.

    For a first excited contribution, write

    W=Ae−V0T(1+ρe−ΔT+⋯ ),ρ≥0,Δ=V1−V0>0.W=Ae^{-V_0 T}(1+\rho e^{-\Delta T}+\cdots), \qquad \rho\ge0,\quad\Delta=V_1-V_0>0.

    Then the exact two-term correction is

    Veff−V0=1aτlog⁡1+ρe−ΔT1+ρe−Δ(T+aτ).V_{\rm eff}-V_0= \frac{1}{a_\tau}\log \frac{1+\rho e^{-\Delta T}} {1+\rho e^{-\Delta(T+a_\tau)}}.

    It is positive and decays at late time. A smooth early-time estimate is not necessarily the ground energy.

    Finite temporal extent is a separate issue. On a periodic lattice of physical duration T\mathcal T, a static-source operator OjO_j maps the no-source Hilbert space to the source sector, giving schematically

    Cij(T)=Tr⁡0 ⁣[e−(T−T)H0Oi†e−THROj]Tr⁡0e−TH0.C_{ij}(T)=\frac{ \operatorname{Tr}_{0}\!\left[ e^{-(\mathcal T-T)H_0} O_i^\dagger e^{-T H_R}O_j \right]} {\operatorname{Tr}_{0}e^{-\mathcal T H_0}}.

    The vacuum spectral sum follows only when the no-source part is vacuum dominated as well. One must control both TT and T−T\mathcal T-T, or fit the appropriate finite-temperature expression. A single-exponential fit is not justified merely because the time direction is periodic.

    Improve the overlap without changing the question

    Spatial smearing replaces a thin path by a gauge-covariant combination of nearby spatial paths with the same endpoints. A direct link and a spatial staple have the same endpoint law, so a weighted sum transforms correctly; a suitable projection back to the gauge group can make it a smeared link. Smearing on one time slice changes the trial state. With the action and temporal propagation held fixed, it changes the coefficients cnc_n, not the exact energies.

    Several smearings or path shapes provide operators OiO_i. If matter can screen the charges, include operators making two screened sources as well. Their correlator matrix has the form

    Cij(T)=∑nZinZjn∗e−VnT.C_{ij}(T)=\sum_n Z_{in}Z_{jn}^*e^{-V_nT}.

    Solve C(T)vn=λn(T,T0)C(T0)vnC(T)v_n=\lambda_n(T,T_0)C(T_0)v_n on a well-conditioned independent operator space. If the operators span exactly NN energy states, then C(T)=Z diag⁡(e−VnT)Z†C(T)=Z\,\operatorname{diag}(e^{-V_nT})Z^\dagger with invertible ZZ, and the generalized eigenvalues are exactly e−Vn(T−T0)e^{-V_n(T-T_0)}. Additional states introduce corrections; nearly dependent operators amplify statistical errors. Time-window and basis variation are both necessary.

    This construction, including flux and screened-source operators, is given in Knechtli–Sommer, §3.1, Eqs. (22)–(30), and §3.2 (PDF). The gauge–Higgs calculation implements a two-operator matrix in a constrained finite Hamiltonian and compares it with the full spectrum.

    A potential does not by itself measure a transverse flux profile. Let W(R,T)\mathcal W(R,T) denote the unaveraged normalized loop whose mean is WW. For a gauge-invariant local action-density probe s(z)s(z), one can instead study the connected insertion

    Δs(z;R,T)=⟨W(R,T)s(z)⟩⟨W(R,T)⟩−⟨s(z)⟩.\Delta s(z;R,T)= \frac{\langle \mathcal W(R,T)s(z)\rangle}{\langle \mathcal W(R,T)\rangle} -\langle s(z)\rangle.

    Place the probe near the temporal midpoint and take the same projection limits before interpreting its spatial distribution. Its conversion to a renormalized energy density needs an operator normalization and continuum analysis. In the 1+11+1-dimensional pure gauge example below there is no transverse coordinate, so neither a transverse tube width nor spatial-staple smearing is available.

    An exactly checkable open gauge ensemble

    Take 12×1212\times12 plaquettes with open boundaries in both Euclidean directions, hence 13×1313\times13 sites. For unit-charge U(1)U(1) links,

    SE=β∑p(1−cos⁡θp),β=1e2asaτ.S_E=\beta\sum_p(1-\cos\theta_p),\qquad \beta=\frac{1}{e^2a_sa_\tau}.

    Here ee has mass dimension one. In a maximal-tree gauge on this open grid, the remaining plaquette angles are independent with density

    p(θ)=eβcos⁡θ2πI0(β),u≡⟨eiθ⟩=I1(β)I0(β).p(\theta)=\frac{e^{\beta\cos\theta}}{2\pi I_0(\beta)},\qquad u\equiv\langle e^{i\theta}\rangle =\frac{I_1(\beta)}{I_0(\beta)}.

    The modified Bessel coefficients follow from In(β)=∫−ππdθ eβcos⁡θcos⁡(nθ)/(2π)I_n(\beta)=\int_{-\pi}^{\pi}d\theta\,e^{\beta\cos\theta}\cos(n\theta)/(2\pi). The character method and its coefficient normalization are discussed in Bonati–Rossi, §II, Eqs. (2) and (12)–(14). Their Abelian action has coefficient 2βsource2\beta_{\rm source}, so our β=2βsource\beta=2\beta_{\rm source}. The open-boundary factorization used here has no periodic plaquette constraint.

    To construct actual links, label plaquettes by (x,t)(x,t) and set

    Vx(x,t)=1,Vτ(x,t)=exp⁡ ⁣[i∑j=0x−1θj,t].V_x(x,t)=1,\qquad V_\tau(x,t)= \exp\!\left[i\sum_{j=0}^{x-1}\theta_{j,t}\right].

    The positive plaquette traverses +x,+τ,−x,−τ+x,+\tau,-x,-\tau and is eiθx,te^{i\theta_{x,t}}. Interior links cancel in a rectangle, leaving the product of its rtrt plaquettes. Independence therefore proves

    W(r,t)=urt,aτV(r)=−rlog⁡u,asaτσ=−log⁡u.W(r,t)=u^{rt},\qquad a_\tau V(r)=-r\log u,\qquad a_sa_\tau\sigma=-\log u.

    This equality is exact for every rectangle contained in the open grid. There is no excited exponential hidden behind it. The gauge choice is a device for exact sampling; loop measurements do not depend on that choice.

    At large β\beta, u=1−1/(2β)+O(β−2)u=1-1/(2\beta)+O(\beta^{-2}). Therefore

    V(R)=−rlog⁡uaτ⟶e2R2.V(R)=\frac{-r\log u}{a_\tau} \longrightarrow\frac{e^2R}{2}.

    This is the continuum tension of this two-dimensional Abelian theory.

    Fit the sampled loops with their shared covariance

    The retained calculation uses β=4\beta=4, seed 741025741025, and N=32768N=32768 independent configurations from NumPy's normalized von Mises sampler. It reconstructs the links and multiplies the four rectangle sides. For each configuration bb, the real parts of all allowed translated loops of each r=1,…,4r=1,\ldots,4, t=1,…,5t=1,\ldots,5 rectangle are averaged into one number wb,αw_{b,\alpha}, where α=(r,t)\alpha=(r,t). Charge-conjugation symmetry makes the ensemble mean real.

    Overlapping translations are correlated; they are not extra independent configurations. Different loop shapes on the same configuration are also correlated. With w‾α=N−1∑bwb,α\overline w_\alpha=N^{-1}\sum_b w_{b,\alpha}, estimate the covariance of the means by

    Σαγ=1N(N−1)∑b(wb,α−w‾α)(wb,γ−w‾γ).\Sigma_{\alpha\gamma} =\frac{1}{N(N-1)} \sum_b(w_{b,\alpha}-\overline w_\alpha) (w_{b,\gamma}-\overline w_\gamma).

    All retained means are positive. Fit

    yrt=log⁡w‾rt≃log⁡Ar−Ert,Er=aτV(r),y_{rt}=\log\overline w_{rt} \simeq \log A_r-\mathcal E_r t,\qquad \mathcal E_r=a_\tau V(r),

    using the full covariance (Σy)αγ≃Σαγ/(w‾αw‾γ)(\Sigma_y)_{\alpha\gamma}\simeq \Sigma_{\alpha\gamma}/(\overline w_\alpha\overline w_\gamma). This delta-method expression is a large-sample approximation for the logarithm. A noisy nonpositive mean cannot be logged; dropping such loops selectively would bias the analysis. One should improve the signal or fit the original correlators with a suitable statistical model.

    There are eight fitted parameters: an amplitude and energy for each of four separations. The joint generalized least-squares solution minimizes (y−Xθ)TΣy−1(y−Xθ)(y-X\theta)^T\Sigma_y^{-1}(y-X\theta), with each row of XX containing the corresponding 1,−t1,-t pair. The calculation also deletes each complete configuration in turn, recomputes every mean and logarithm, and refits with the full-sample covariance weights held fixed. The jackknife covariance is

    Cov⁡J(θ)=N−1N∑b(θ(−b)−θ‾J)(θ(−b)−θ‾J)T.\operatorname{Cov}_{J}(\theta)= \frac{N-1}{N}\sum_b (\theta^{(-b)}-\overline\theta_J) (\theta^{(-b)}-\overline\theta_J)^T.

    Every separation and time is omitted together on each replica. The fixed weights do not propagate uncertainty in the estimated weight matrix itself; with these independent samples, the resulting energy errors agree with linear covariance propagation to about one part in a million. That agreement checks the nonlinear propagation locally, not an omitted systematic effect.

    The fit ranges t=1t=1–55 and t=2t=2–55, the sample size and the seed were specified before examining the sampled results. No configuration, mean or jackknife replica was discarded, and the seed was not changed to improve agreement. The first window gives:

    rrExact aτV(r)a_\tau V(r)Fitted aτV(r)a_\tau V(r)Fitted aτ[V(r)−V(1)]a_\tau[V(r)-V(1)]
    110.1467350.1467350.146921±0.0001800.146921\pm0.00018000
    220.2934700.2934700.294074±0.0004700.294074\pm0.0004700.147153±0.0003490.147153\pm0.000349
    330.4402060.4402060.441690±0.0009060.441690\pm0.0009060.294769±0.0008100.294769\pm0.000810
    440.5869410.5869410.588848±0.0015360.588848\pm0.0015360.441927±0.0014580.441927\pm0.001458

    The errors are jackknife standard errors. The fit has χ2=12.14\chi^2=12.14 for 1212 degrees of freedom; this is a consistency diagnostic with estimated covariance, not a guarantee of model validity. The full log-covariance condition number is about 4.1×1054.1\times10^5; no covariance modes were removed.

    Differences cancel the static energy offset

    In a general regulated theory, each static source contributes a regulator-dependent self energy. Thus the bare potential contains an additive 2δm(a)2\delta m(a), which may diverge as the regulator is removed. The energy zero is part of the static-source convention; it cannot be inferred from the loop slope alone.

    At fixed action and source representation,

    ΔV(R,R0)=V(R)−V(R0)\Delta V(R,R_0)=V(R)-V(R_0)

    cancels the common offset. A finite-difference force divides such a difference by the spatial separation increment. The covariance matters:

    Var⁡(Vr−V1)=Var⁡(Vr)+Var⁡(V1)−2Cov⁡(Vr,V1).\operatorname{Var}(V_r-V_1)= \operatorname{Var}(V_r)+\operatorname{Var}(V_1) -2\operatorname{Cov}(V_r,V_1).

    For the r=2r=2 result, the dimensionless fitted-energy covariance is 6.57×10−86.57\times10^{-8}. Including it gives error 0.0003490.000349 for the difference; treating the energies as independent would give about 0.0005030.000503. The cancellation removes an additive convention, not discretization errors or finite-time contamination.

    The following plot compares both predetermined fit windows with the exact difference. Their errors and fluctuations are correlated because they use the same configurations.

    Potential differences from two correlated fit windows follow the exact linear open U1 result at four lattice separations.

    Potential differences on 3276832768 independent open 12×1212\times12 compact-U(1)U(1) configurations at β=4\beta=4. The vertical quantity is aτ[V(r)−V(1)]a_\tau[V(r)-V(1)]. Points use joint fits over t=1t=1–55 or t=2t=2–55; bars are configuration-jackknife standard errors with shared covariance, sometimes smaller than the markers. Horizontal offsets distinguish the two windows. The line is the exact (r−1)[−log⁡(I1/I0)](r-1)[-\log(I_1/I_0)], not a fit to the data.

    At r=4r=4, the later window gives aτV=0.590120±0.002748a_\tau V=0.590120\pm0.002748, compared with 0.588848±0.0015360.588848\pm0.001536 for the first window. There is no true excited-state contribution in this model; changing the window only changes which noisy correlated data determine the estimate.

    For the first window, sample prefixes of 81928192, 1638416384 and 3276832768 configurations give the r=4r=4 energies

    0.58758±0.00308,0.58870±0.00217,0.58885±0.00154.0.58758\pm0.00308,\qquad 0.58870\pm0.00217,\qquad 0.58885\pm0.00154.

    The uncertainty decreases approximately as N−1/2N^{-1/2}. Prefixes are nested, so these are not three independent determinations. The largest discrepancy among the twenty mean loops and their exact values is 2.292.29 standard errors; some exact values lying outside one-standard-error intervals is expected in a noisy sample.

    Direct complex link products agree with the separate plaquette-area calculation to 6.2×10−156.2\times10^{-15}, and nontrivial local gauge transformations change them by at most 2.3×10−152.3\times10^{-15} in the checks. These tests would detect an orientation or reconstruction mistake that a fit alone might conceal.

    Reproduce the calculation and figure with Python 3, NumPy, SciPy and Matplotlib:

    python3 examples/lattice-hamiltonian/lattice-gauge-theory/static_potential.py
    python3 examples/lattice-hamiltonian/lattice-gauge-theory/plot_static.py
    

    The retained run used Python 3.9.6, NumPy 2.0.2 and SciPy 1.13.1. static-results.json retains the loop covariance, both fits, their energy and difference covariances, and prefix checks. The shared u1.py stream also supplies the gradient-flow example. This calculation verifies a finite open gauge ensemble and its statistics. It neither performs a continuum extrapolation nor tests transverse flux excitations.

    Summary

    A Wilson loop yields a static energy through Euclidean projection in a specified source sector. The operator overlap, temporal boundaries and additive source convention determine how that energy can be interpreted. The open U(1)U(1) calculation makes the statistical extraction fully checkable: reconstructed links give the exact area-law target, and common-configuration resampling gives meaningful uncertainties for potential differences.

    Exercises

    The sign of excited-state contamination

    For the two-term correlator above, expand Veff−V0V_{\rm eff}-V_0 to first order in ρe−ΔT\rho e^{-\Delta T}. Explain why increasing the time step does not remove the need for late-time projection.

    Solution

    Using log⁡(1+x)=x+O(x2)\log(1+x)=x+O(x^2) gives

    Veff−V0=ρaτ(1−e−Δaτ)e−ΔT+O ⁣(ρ2e−2ΔTaτ).V_{\rm eff}-V_0= \frac{\rho}{a_\tau} (1-e^{-\Delta a_\tau})e^{-\Delta T} +O\!\left(\frac{\rho^2e^{-2\Delta T}}{a_\tau}\right).

    The leading correction is positive. For any finite chosen step, a sufficiently early start time can still have a large excited contribution. Increasing the interval also pushes its later endpoint into a noisier part of the correlator and does not fix a zero or tiny ground-state overlap.

    A perimeter-canceling loop ratio

    Define

    χ(r,t)=−log⁡W(r+1,t+1)W(r,t)W(r+1,t)W(r,t+1).\chi(r,t)=-\log \frac{W(r+1,t+1)W(r,t)} {W(r+1,t)W(r,t+1)}.

    Evaluate it in the exact open U(1)U(1) ensemble. If a general loop has an additional factor exp⁡[−c(r+t)]\exp[-c(r+t)], does that factor survive? What information is needed to assign an error to a measured χ\chi?

    Solution

    The area exponent in the ratio is (r+1)(t+1)+rt−(r+1)t−r(t+1)=1(r+1)(t+1)+rt-(r+1)t-r(t+1)=1, so

    χ(r,t)=−log⁡u=asaτσ.\chi(r,t)=-\log u=a_sa_\tau\sigma.

    The perimeter exponents cancel because (r+t+2)+(r+t)−(r+t+1)−(r+t+1)=0(r+t+2)+(r+t)-(r+t+1)-(r+t+1)=0. For measured means, let yy contain their four logarithms in the displayed numerator/denominator order. Then χ=(−1,−1,+1,+1)⋅y\chi=(-1,-1,+1,+1)\cdot y, and its variance is the corresponding quadratic form in the full covariance of yy. Jointly resampling configurations supplies that covariance. Four separate error bars without their correlations are insufficient.

    The exact constant result is special to this model. In other theories finite-loop excitations, corner terms and cutoff effects can remain after perimeter cancellation.

    References

    • Bonati, Claudio, and Paolo Rossi. “The topological susceptibility of two-dimensional U(N)U(N) gauge theories.” Physical Review D 99 (2019), 054503. arXiv:1901.09830v3, §II, Eqs. (2), (12)–(14). The coefficient of the Abelian cosine is twice their β\beta.
    • Knechtli, Francesco, and Rainer Sommer. “String breaking as a mixing phenomenon in the SU(2) Higgs model.” Nuclear Physics B 590 (2000), 309–328. arXiv:hep-lat/0005021 (PDF), §3.1, Eqs. (22)–(30), and §3.2.1–3.2.3 for subtraction and overlaps.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.