- Home
- Library
- Lattice and Hamiltonian Field Theory
- Scale Setting and Physical Limits
- Continuum and Infinite-Volume Extrapolations
Continuum and Infinite-Volume Extrapolations
A precise number on one lattice can still be a precise answer to the wrong limiting problem. We will separate spacing and spatial-volume effects in an exactly soluble scalar response, recover its known continuum answer, and then fit explicitly synthetic correlated data. The examples show what a fit tests and what its statistical error leaves out.
Preparation: A line of constant physics, lattice artifacts and elementary least squares.
A free response with two independently variable limits
Consider the free scalar in one spatial dimension, with a periodic circle of length . Its zero-Euclidean-frequency response obeys a discrete Helmholtz equation. Define
The sum has distinct momenta. This is a static Green function, obtainable by integrating the Euclidean two-point function over time, not the coincident two-dimensional field variance. In one spatial dimension its coincident continuum limit is ultraviolet finite.
Tune the exponential spatial decay rate using . On the infinite lattice, the decaying solution of the homogeneous difference equation is proportional to . The source equation at fixes its coefficient:
Periodizing this solution sums images at . At , the geometric series gives the dimensionless observable
Its continuum infinite-volume value is exactly 1. Its factors isolate two errors:
The volume correction is positive and the leading cutoff correction negative. They can cancel accidentally. One nearly correct value is therefore weak evidence about either limit.
The retained calculation evaluates the finite momentum sum at and . It also inverts an independently assembled periodic difference matrix for , . Both agree with the image formula to better than . Those are implementation checks against a known response, not uncertainty estimates for an interacting theory.
The figure shows why a family of spacings is needed at each volume. The curves are exact finite-lattice results, and their different intercepts survive the continuum limit.
Exact static response versus , with the pole mass fixed and periodic spatial circles . Markers show the four evaluated spacings. The dashed horizontal line is the continuum, infinite-volume value. At fixed , refinement approaches , not exactly one. Both axes are dimensionless; no Monte Carlo data are plotted.
Extrapolate a quantity whose answer is known
In this solved example we can divide out the exact volume factor. Set and fit
This uses analytic knowledge specific to the benchmark; real data do not generally have an exact finite-volume correction available. The deterministic fits give:
| Spacings used | Fit terms | Continuum intercept |
|---|---|---|
| All four | 0.9999997540 | |
| Three finest | 0.9999999922 | |
| Three finest | 0.9999899912 |
The three-point quadratic interpolation has no residual degrees of freedom. Its small error is known because we have an exact answer and an analytic expansion, not because its residual vanishes. The difference between the quadratic and linear extrapolations exposes neglected terms; it is not by itself a probabilistic error bar.
If instead we first take at fixed , the resulting must still be extrapolated to large . Here the two limits commute because the exact expression factorizes and is regular for positive . At a critical point, in a massless theory, or with a changing state, this simple argument no longer applies.
The form of cutoff corrections should come from the action and observable. Powers can be modified by logarithms, as discussed in Weisz, §§4.2–4.3, printed pp.41–43 (PDF). The exponential corrections here describe the images of the massive free static response.
Correlated synthetic data
To demonstrate statistical inference with a known target, generate sixteen synthetic ratios, not scalar Monte Carlo measurements. Let and . Define , , and generate
The volume form is chosen as a teaching model of an exponentially suppressed massive correction. Its exact form and all coefficients are known inputs to this synthetic experiment; no interacting field-theory result is inferred from them.
Add a centered Gaussian vector with covariance
The second term is a shared offset uncertainty; the third correlates measurements at the same spacing. The retained generator uses NumPy's default random generator with seed 20261025 and stores the full data and covariance. There is no seed selection based on the fit result.
For a linear ansatz , minimize
Factor and solve ordinary least squares for and . This avoids forming the covariance inverse. With a known covariance, full column rank and the stipulated Gaussian noise, the fitted coefficient covariance is . That expression measures noise under the chosen model; it contains no allowance for omitted physical terms.
The actual retained realization gives:
| Fit | Continuum ratio | /degrees of freedom |
|---|---|---|
| 14.08/11 | ||
| 14.61/13 | ||
| , omitting volume terms | 37.86/14 | |
| Full model, discard | 8.28/7 |
The generating continuum ratio is 1.7. One realization is allowed to fluctuate away from it. Dropping the coarsest data increases the uncertainty and shifts the intercept; extra fit flexibility is not automatically extra information. Omitting volume dependence gives a visibly worse fit and a misleadingly precise intercept. A noise-free replay recovers all generating coefficients to better than , independently checking the fitting implementation.
Replacing the covariance with its diagonal leaves the full-model intercept unchanged in this balanced example but reduces its reported uncertainty to 0.00175. That accidental equality of central values does not justify ignoring correlations. A shared offset moves an extrapolated intercept without producing scatter among points, so additional points cannot average that component away.
Applying the procedure to an interacting calculation
For the two-dimensional scalar, first identify the renormalized tuning conditions, such as fixed and on a specified geometry. Measure an observable not used to fix those conditions. A continuum result at that fixed finite volume is already meaningful. To obtain an infinite-volume result, extend the volume study while retaining the same renormalized theory; repeatedly retuning a finite-volume definition of to the same number as changes need not keep the infinite-volume theory unchanged.
Measure several spacings at overlapping physical volumes. If every fine lattice is also the largest volume, cutoff and volume coefficients can become nearly indistinguishable. Propagate scale and tuning errors jointly, including uncertainty in the horizontal variables and ; a fit treating them as exact is justified only when those errors are negligible or separately controlled. The synthetic experiment above deliberately gives exact horizontal inputs.
Vacuum spectroscopy has another limit. At finite periodic Euclidean time , even a single state gives a forward and backward contribution,
Excited states and thermal terms can alter the omitted contributions. Increasing at fixed increases physical time; reducing at fixed only resolves the same time interval better. Vary fit windows, enlarge when necessary, and include the appropriate spectral form. The static free benchmark above isolates a zero-frequency response and does not test an interacting ground-state projection.
Finally compare justified fit forms, restricted spacing ranges and enlarged volumes. Inspect residuals and parameter correlations. Report statistical uncertainty separately from assumptions that the data cannot discriminate. A good fit to a small set of points is evidence of compatibility, not proof of a continuum theory or of the absence of a missed systematic effect.
Summary
Spacing, spatial volume and Euclidean projection time control different approximations. Exact scalar response functions provide a stringent benchmark because their finite-spacing and image effects are known separately. Correlated fits can then estimate a limiting observable, provided the theory, geometry, ansatz and remaining uncertainties are explicit.
Exercises
Accidental cancellation
Using only the leading terms , find the volume at which the two leading errors cancel when . Does this make either error negligible?
Solution
Cancellation requires , hence . Each leading contribution has magnitude , about one percent. Their sum vanishes only at this order and chosen point. Changing the spacing or volume separately exposes the errors. The exact expression also contains higher powers and products, so the leading cancellation is not exact.
A common error that never averages away
Suppose estimates of a constant have covariance . Find the variance of their mean and compare it with treating their errors as independent.
Solution
The equally weighted mean is optimal by permutation symmetry. Its variance is
The shared component survives as . Keeping only diagonal entries would give , spuriously averaging away the common uncertainty. A scale input or calibration uncertainty can produce exactly this type of correlation.
References
- P. Weisz, “Renormalization and lattice artifacts,” lectures at the 2009 Les Houches school (2010), arXiv:1004.3462, §§4.1–4.3 (PDF).
Reproduce the deterministic response, synthetic data and fits with examples/lattice-hamiltonian/lattice-fields/limits.py; plot_limits.py generates the original figure from the retained results.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.