- Home
- Library
- Lattice and Hamiltonian Field Theory
- Hadron Operators and Gauge-Invariant Spectra
- Hadron Operators and a Worked Finite Gauge Spectrum
Hadron Operators and a Worked Finite Gauge Spectrum
How do gauge-invariant correlation functions become a spectrum? A useful calculation needs an operator with the right quantum numbers, a specified gauge theory and sampling measure, and an extraction that survives changes of basis and time window. A small statistical error is only one part of that argument.
Here we carry out the full sequence in an explicitly labeled teaching model: a -dimensional gauge Hamiltonian on a periodic spatial lattice. Exact diagonalization supplies the reference spectrum; an actual conditional Monte Carlo sample supplies correlated measurements. The calculation resolves a lowest scalar-channel gap near in the stated Hamiltonian units. It also rejects an apparently convincing one-state fit.
Preparation: finite-time correlators, correlated fits, the variational method and lattice quantum numbers.
What a hadron calculation must measure
The four-site quark contraction obtains a measured correlator from a Dirac inverse. The Hamiltonian calculation below instead uses closed gauge loops, so its scalar-sector overlaps can be checked without a quark inversion. Both calculations still require a source operator and a specified gauge average.
In QCD, gauge-invariant meson bilinears, three-quark baryon operators and closed gluonic loops can all create finite-volume energy eigenstates. A meson contraction contains inverse Dirac matrices; a baryon contraction includes color antisymmetrization and identical-quark exchange. A pure-gauge loop needs no valence propagator. In full QCD, scalar loop operators can mix with quark-antiquark and multi-hadron operators of the same exact quantum numbers. The labels “meson-like” and “glueball-like” describe the construction of a basis, not a conserved composition of an eigenstate.
For example, the positive flavor-changing pseudoscalar convention of quark contractions gives
for degenerate valence flavors. The trace closes spin and color, and the gauge expectation includes the chosen sea determinants. Flavor-singlet channels require disconnected loops as well. The general passage from fermion integration to a gauge-ensemble average is reviewed in Briceño, Dudek and Young, §III, Eqs. (7)–(9), PDF pp. 5–6.
A measured energy in lattice units must eventually be combined with a scale and the ensemble parameters. For an isotropic Euclidean calculation, ; an anisotropic calculation needs for energies and its calibrated relation to . Quark masses, physical volume and lattice spacing must be varied with the intended renormalized physics held fixed. A good fit on one ensemble performs none of these extrapolations. Our example has no sea quarks and no physical calibration of its energy unit ; we report and do not assign MeV.
A small physical gauge Hilbert space
Put Pauli operators on the 18 links of the square spatial torus. Define
Physical states obey at every vertex. A plaquette meets a star in zero or two links, so ; the Hamiltonian preserves the physical space. We set and , and measure Euclidean times in . This local Hamiltonian/Gauss construction is also described, with and interchanged and a different lattice drawing, in Zhang, §II, Eqs. (1)–(6), PDF p. 2. The geometry and numerical results below are defined independently here.
There are nine vertices, but only eight independent Gauss constraints because . Thus
Two additional conserved signs are products of on links crossed by the two noncontractible dual cuts. We choose . Each of the four electric-winding sectors has dimension 256. Every contractible plaquette or rectangle preserves these signs. A noncontractible Wilson loop made of can change them.
The companion constructs this space without gauge fixing: enumerate link-electric eigenvalues , retain the Gauss constraints and the two winding signs, put on the diagonal, and let each flip its four boundary link bits.
A second representation checks the construction
In the chosen sector, use nine dual plaquette spins with magnetic eigenvalues and the constraint . The last relation follows because every link occurs twice in the product of all plaquettes. There are again basis states. The same Hamiltonian becomes
The 18 neighboring plaquette pairs correspond to original links. Acting with one electric link flips its two adjacent magnetic plaquettes. The Gauss constraints make products around contractible dual loops consistent; fixing both electric winding signs to plus permits all the displayed pair-flip coefficients to be untwisted. Other electric-winding sectors require twisted signs. They are not included by merely tracing over this periodic dual matrix.
Independent diagonalizations in the link-electric and dual-magnetic bases agree for every eigenvalue to . The ground energy is
In the magnetic basis all off-diagonal Hamiltonian entries are nonpositive. Therefore has nonnegative entries for ; expanding with sufficiently large proves this directly. Neighboring pair flips connect all even-parity bit strings, giving strictly positive entries at positive time. This positivity will make the conditional sample an ordinary probability calculation.
Choose local scalar-channel operators
Use the two diagonal magnetic operators
Adjacent plaquettes share a link whose two factors cancel, so is a contractible rectangle. Both operators average translations and orientations. They have zero momentum and belong to the reflection-even representation of the square group . The use of matters: on a torus a length-two rectangle already spans an entire periodic direction.
The actual representation check averages all nine translations and eight square rotations/reflections. If projects to zero momentum and averages , then
All 72 permutation matrices commute exactly with the Hamiltonian. The 13-dimensional scalar space includes the vacuum, so two operators plainly do not span all its excitations. In two spatial dimensions includes continuum spin with even reflection parity; it also permits multi-particle levels. Charge conjugation acts trivially for this real gauge group. The distinction from continuous rotations is discussed in Caselle, Hasenbusch and Provero, §2, PDF p. 2.
The lowest relevant spectral groups are listed below. The plaquette and rectangle weights are respectively and , where
| Gap | Degeneracy | Zero-momentum assignment | Plaquette weight | Rectangle weight |
|---|---|---|---|---|
| 1 | ||||
| 4 | No zero-momentum component | |||
| 4 | No zero-momentum component | |||
| 1 | ||||
| 1 | ||||
| 1 |
The table selects groups to explain the overlaps; it is not a list of every intermediate level. Numerical zeros are below . The companion aggregates weights over degenerate eigenspaces rather than assigning a physical meaning to an arbitrary eigenvector returned inside a degeneracy. The rectangle has much greater relative overlap with higher scalar levels, making it useful as a second basis direction.
Across different winding sectors, the and ground energies lie only above the vacuum. Those lower gaps cannot appear in our local scalar vacuum correlator. Calling the lowest energy anywhere in the physical Hilbert space the “plaquette glueball mass” would confuse a winding-sector excitation with the selected local channel.
Retain the complete finite-time trace
Let , , and . All traces here run over the entire 256-state sector, not only its zero-momentum scalar states. For ,
Thermally occupied nonzero-momentum states can contribute transitions with the same momentum at the two insertions. Scalar vacuum selection rules do not remove those terms from a thermal trace.
The forward vacuum reference is a different object:
Our matrices are real. At large , terms with a vacuum on either side give forward and backward exponentials. A single-cosh model further assumes one relevant excited state and neglects the remaining thermal transitions and diagonal thermal fluctuations. Those assumptions can be tested here rather than inferred from a flat-looking graph.
We fix and record . At the relative difference is
| Temporal extent | Relative difference at |
|---|---|
| 2 | |
| 3 | |
| 4 |
These exact comparisons include backward propagation as well as excited thermal transitions. Even a small correlator difference can matter when an energy is inferred from two nearly correlated measurements. Changing in this table is an exact trace check, not an additional sampled ensemble or a spatial-volume extrapolation.
Sample an actual positive distribution
Let label an even-parity magnetic bit string and let be its diagonal operator value. Draw independent starting states with
For a given start , the intermediate state at time has the normalized bridge probability
Its normalization is precisely the semigroup identity . Instead of drawing , sum it exactly. With , measure
Averaging over gives the connected trace. We use to produce a symmetric measured matrix. The exact thermal means are deliberately supplied, isolating sampling and spectral-extraction errors; estimating the means from data would add correlated subtraction errors. The transfer matrices come from exact diagonalization, so there is no time-step/Trotter approximation.
The retained run uses 262,144 independent draws, NumPy SeedSequence([771025,20]), and the same starts for every time and operator. There is no Markov-chain warm-up or autocorrelation correction. This is conditional Monte Carlo on the actual finite gauge model, not Gaussian noise placed on a target curve. A few results are:
| Exact | Sample mean | Standard error | |
|---|---|---|---|
| 0.1 | |||
| 0.5 | |||
| 0.8 |
After one dense 256-dimensional eigensystem, the implementation constructs 17 kernels: one at and two at each of eight times. Each uses a dense product. Conditioning requires eight elementwise products and eight multiplications of a matrix by a matrix. The resulting table contains the three independent correlator components at eight times. Each draw then looks up a row. Exact conditioning is feasible in this small Hilbert space, but the number of states grows exponentially with system size. Spectral checks, covariance formation and fitting are additional work.
The covariance rejects a deceptively good energy
If is the 24-component measurement vector, the covariance of its iid sample mean is estimated by
The components are highly correlated because they use the same starts. Moreover, these invariant functions are constant on the 13 spatial-symmetry orbits of magnetic configurations. Centering therefore bounds the exact covariance rank by 12, although there are 24 measured components. At the fixed relative eigenvalue cutoff , both the population and sample covariance retain eight modes. This is not a claim that the exact algebraic rank is eight.
Before production we specified a one-state model
and three five-point windows. Diagonalize each window covariance and retain eigenvalues greater than times its largest eigenvalue. The correlated residual statistic is
where the superscript means inversion only on retained modes. Every window retains rank three and fits two parameters.
| Window | Fitted | Formal linearized statistical error | on retained modes |
|---|---|---|---|
| — primary | |||
None is an acceptable one-state fit. The primary fit leaves only one retained residual direction after two parameters, yet is thousands. The numerical nearness of to is not evidence of a valid uncertainty estimate. Correlations constrain small changes of curve shape much more tightly than the errors on individual points suggest.
The conclusion survives removing the sampling fluctuation: fitting the exact finite- curve with the same primary covariance gives . Fitting the forward vacuum curve with that same cosh ansatz gives ; here its backward term is tiny over the window. Thus higher-state model error dominates this failure. We do not turn the formal errors into accepted mass errors, attach a calibrated p-value to the covariance-truncated fit, or move the windows until one passes.
Two operators improve one level, but do not complete the spectrum
For adjacent times separated by , solve
In a vacuum correlator with exactly two contributing states and an invertible overlap matrix, these are their two gaps. Here more states contribute. We change at each displayed point; this adjacent-time estimator is not the fixed-reference logarithmic derivative in the standard asymptotic theorem. The usual vacuum GEVP construction and omitted-state analysis are given in Blossier et al., §1.2, Eqs. (1.1)–(1.16), PDF pp. 2–4. We assess our estimator directly against the known spectrum and finite trace.
| Lowest sampled estimate | Statistical error | Lowest forward-vacuum estimate | Second sampled estimate | |
|---|---|---|---|---|
Errors propagate through 64 equal-size delete-one-block jackknife samples, with each block containing 4096 independent starts. Each resample reconstructs the complete matrix pair before solving. At the last pair the exact finite- estimate is . Relative to the exact gap , its components are
The first is higher-state contamination; the second includes backward propagation and other finite-temperature effects; the third is this sample's fluctuation. The total discrepancy is about , much larger than the statistical error. The calculation therefore reproduces the finite-model level near with a quantified finite-time bias, rather than measuring it to the precision suggested by the error bar alone.
Exact forward-vacuum and sampled adjacent-time estimates in the , sector with , . The sample uses and 262,144 independent conditional measurements. The upper panel subtracts the exact lowest gap, exposing bias on a logarithmic scale. The lower panel compares the second estimate with the exact second operator-coupled gap. Error bars show statistical uncertainty only. All points come from the retained calculation.
The second coupled gap is , still far below the last estimate . Its statistical error is only . Two operators improve the lowest-state isolation without resolving every scalar level. The correlation metric's condition number also grows from to over the displayed pairs, making later-time inversions increasingly sensitive to noise.
From this example to a physical spectrum
The result establishes a gauge-invariant scalar-channel energy in a completely specified finite regulator and exhibits the difference between statistical precision and spectral isolation. It uses an actual probability sample, exact contraction by diagonal loop operators, a known symmetry sector, complete covariance propagation and an independent spectral reference. The rejected one-state model is part of the result. The Yang–Mills construction and gap comparison explains what a scale- and volume-uniform spectral bound for an infinite-volume Hamiltonian would have to control.
A QCD extension must replace the tiny conditional sum with a controlled gauge ensemble and the required quark/gluon contractions, keep disconnected terms, and enlarge the operator basis where nearby multi-hadron levels matter. Briceño, Dudek and Young, §V.B.1, PDF pp. 16–18 illustrates why restricted operator bases can miss finite-volume states. Dependence on the sea/valence quark masses, volume, spacing and scale-setting observable requires additional ensembles. Pure-gauge and full-QCD scalar spectra are different theories. No such variations, mass calibration or resonance extraction are supplied by this one calculation.
Exercises
- Set , keep and work in the same sector at zero temperature. Determine the two correlators and the mixed correlator for . What does their adjacent-time GEVP return?
Solution
The vacuum has every . A plaquette flips four electric links, each costing , so its excitation energy is . A contractible rectangle flips six links and costs . On the lattice the nine plaquette states and eighteen rectangle states are mutually orthogonal within each set, and the two sets are disjoint. Their vacuum expectation values vanish. Including the averaging factors gives
The two generalized eigenvalues are and , so the two energies are exactly for every . Degeneracy among unaveraged loop states does not spoil this conclusion: each averaged operator couples to a single energy. Turning on mixes loop configurations and introduces additional energies into each correlator. The companion verifies the three endpoint correlators by an independent magnetic-basis diagonalization.
- Prove that the conditional estimator is unbiased and has no greater variance per independent draw than explicitly sampling the intermediate bridge state. Does this prove it is a more efficient QCD method?
Solution
Draw and then . For the unsymmetrized pair define . The joint probability is , hence summing over reproduces the trace with the two centered insertions. Therefore .
The measured quantity is , so iterated expectation proves unbiasedness. Total variance gives
Apply the same argument to the symmetrized insertion if that is the measured observable. The inequality compares variances per independent start, not errors at equal computational cost. Here the exact conditional sum needs 256 states and dense transfer matrices; its cost grows exponentially with the spatial lattice. This proof supplies no efficient exact conditioning procedure for QCD.
References
- Blossier, B., von Hippel, G., Mendes, T., Sommer, R., and Della Morte, M., “Efficient use of the Generalized Eigenvalue Problem,” Proceedings of Science LATTICE2008, 135 (2008), arXiv:0808.1017, §1.2, Eqs. (1.1)–(1.16).
- Briceño, R. A., Dudek, J. J., and Young, R. D., “Scattering processes and resonances from lattice QCD,” Reviews of Modern Physics 90, 025001 (2018), arXiv:1706.06223, §§III and V.B.1.
- Caselle, M., Hasenbusch, M., and Provero, P., “Spectrum of the gauge Ising model in three dimensions,” Nuclear Physics B Proceedings Supplements 63, 616–618 (1998), arXiv:hep-lat/9709087, §2. Only its symmetry discussion is used here; our Hamiltonian data are independently generated.
- Zhang, D.-B., “Physics-informed quantum algorithms for glueball-like excitations in a lattice gauge theory,” arXiv:2608.25696v2, §II, Eqs. (1)–(7). The source interchanges our electric and magnetic Pauli labels and uses a different geometry.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.