Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Interpolating Operators and Smearing

    Two operators can create the same lowest state while producing very different correlators at accessible time separations. One may also excite many higher states; another may have a weak signal or a noisy cancellation. An interpolating operator chooses these overlaps. It does not choose a different energy spectrum.

    This article constructs operators with definite lattice symmetries, explains spatial smearing with the site's forward-link convention, and tests a genuine composite smearing in the chapter's two-site scalar theory. The test has a useful outcome: stronger smoothing decreases the ground-state fraction of this particular cubic operator. Smoothing is a design choice to assess, not an automatic improvement.

    Preparation: The finite-time spectral sum, gauge links and their endpoints, and basic matrix eigenvectors. Fermionic applications also use quark contractions.

    Choose quantum numbers before choosing a shape

    At zero temperature, an operator OaO_a on one time slice has overlaps

    za(n)=⟨0∣Oa∣n⟩,Cabvac(t)=∑nza(n)zb(n)∗e−Ent.z_a^{(n)}=\langle0|O_a|n\rangle, \qquad C^{\rm vac}_{ab}(t)=\sum_n z_a^{(n)}z_b^{(n)*}e^{-E_nt}.

    We use unit-normalized finite-volume states and gaps measured above the vacuum. Changing OaO_a changes za(n)z_a^{(n)}; the action and transfer operator still determine EnE_n. An operator is useful only if it has nonzero overlap with the state of interest and permits a statistically informative measurement.

    A spatial momentum projection can be defined by

    Op(t)=Ns−ds/2∑xe−ip⋅xO(t,x),O_{\boldsymbol p}(t)=N_s^{-d_s/2} \sum_{\boldsymbol x}e^{-i\boldsymbol p\cdot\boldsymbol x}O(t,\boldsymbol x),

    on a dsd_s-dimensional spatial lattice of NsN_s sites per direction. This displayed phase is the local projection convention. The zero-momentum example below is independent of the phase choice. Rotations surviving the lattice regulator, parity, internal charges and flavor further select the channel. A cubic lattice has discrete rotation representations, rather than exact continuum spin labels; the multi-hadron construction develops that distinction.

    For a simple parity symmetry PP, an operator with POaP−1=paOaPO_aP^{-1}=p_aO_a connects states only when prps=pap_rp_s=p_a. In a thermal correlator this rule constrains transitions between any two occupied states, not only vacuum-to-particle transitions. See the explicit spectral matrix in the preceding article. The use of quark bilinears and baryon contractions to realize selected quantum numbers is illustrated in Gupta, §17.2 and Table 8, printed pp. 111–112, PDF.

    Spatial smearing changes an insertion

    For a scalar field, a normalized spatial kernel defines

    ψ(t,x)=∑yK(x,y)φ(t,y).\psi(t,\boldsymbol x)=\sum_{\boldsymbol y} K(\boldsymbol x,\boldsymbol y)\varphi(t,\boldsymbol y).

    Both fields belong to the same time slice. Correlators of ψ\psi, or of composites made from it, are measured with the original weight e−S[φ]e^{-S[\varphi]}. Replacing the fields in the action would instead define a different action and generally a different spectrum. No such replacement is made here.

    The motivation is spectral: if ∣z(2)/z(1)∣|z^{(2)}/z^{(1)}| becomes smaller while the signal remains measurable, a lower-state approximation can become useful at an earlier separation. But statistical variance also changes. A source with a small excited overlap can still be expensive or noisy. This overlap-versus-noise problem motivates the Wuppertal-smearing study in Della Morte et al., §1, printed p. 1, PDF.

    There is an important elementary counterexample. If K(x,y)=w(x−y)K(\boldsymbol x,\boldsymbol y)=w(\boldsymbol x-\boldsymbol y) is translation invariant, then

    ∑xψ(t,x)=(∑xw(x))∑yφ(t,y).\sum_{\boldsymbol x}\psi(t,\boldsymbol x) =\left(\sum_{\boldsymbol x}w(\boldsymbol x)\right) \sum_{\boldsymbol y}\varphi(t,\boldsymbol y).

    For a normalized kernel, the elementary zero-momentum field is unchanged. Several such smearings therefore give proportional operators and a rank-one correlator matrix, configuration by configuration. They cannot isolate several zero-momentum levels. A localized unprojected smeared field can suppress nonzero spatial momenta, but that is a momentum mixture. To change relative momentum content at fixed total momentum, construct a composite before the final projection.

    Gauge covariance fixes the hopping directions

    For fundamental matter ψ(x)↦G(x)ψ(x)\psi(x)\mapsto G(x)\psi(x), this volume uses a forward link

    Vi(x)↦G(x+i^)Vi(x)G†(x).V_i(x)\mapsto G(x+\widehat i)V_i(x)G^\dagger(x).

    It transports from xx to x+i^x+\widehat i. To bring a neighboring field back to xx, use the inverse transporter. The spatial hopping operator is therefore

    (HVψ)(x)=∑i=1ds[Vi†(x)ψ(x+i^)+Vi(x−i^)ψ(x−i^)].(H_V\psi)(x)=\sum_{i=1}^{d_s}\left[ V_i^\dagger(x)\psi(x+\widehat i) +V_i(x-\widehat i)\psi(x-\widehat i) \right].

    For example, Vi†(x)ψ(x+i^)V_i^\dagger(x)\psi(x+\widehat i) transforms as G(x)Vi†(x)G†(x+i^)G(x+i^)ψ(x+i^)G(x)V_i^\dagger(x)G^\dagger(x+\widehat i)G(x+\widehat i)\psi(x+\widehat i), which is G(x)G(x) times the original expression. The other term works in the same way. Hence every polynomial in HVH_V is gauge covariant.

    A normalized iterative smearing is

    ψ(n)=(1+κHV1+2dsκ)nψ,κ≥0.\psi^{(n)}=\left(\frac{1+\kappa H_V}{1+2d_s\kappa}\right)^n\psi, \qquad \kappa\geq0.

    The normalization is convenient and can be absorbed into an overlap. In a trivial gauge background its momentum multiplier is

    K~(p)=[1+2κ∑icos⁡(aspi)1+2dsκ]n≃exp⁡ ⁣[−nκas2p21+2dsκ]\widetilde K(\boldsymbol p)= \left[\frac{1+2\kappa\sum_i\cos(a_sp_i)}{1+2d_s\kappa}\right]^n \simeq \exp\!\left[-\frac{n\kappa a_s^2\boldsymbol p^2}{1+2d_s\kappa}\right]

    at small as∣p∣a_s|\boldsymbol p|. This explains the approximate Gaussian shape. It is not an exact Gaussian kernel on an arbitrary gauge configuration. Della Morte et al., §2, Eqs. (2)–(5), printed pp. 2–3, PDF write the first hopping term with Ui(x)U_i(x). Their link is the backward transporter in our notation, so Ui(x)=Vi†(x)U_i(x)=V_i^\dagger(x); the two formulas then coincide, apart from our optional normalization.

    A color-singlet bilinear ψ(n)‾Γψ(n)\overline{\psi^{(n)}}\Gamma\psi^{(n)} is gauge invariant because both smeared fields transform at the same endpoint. A plain spatial average of colored fields without transporters has no such property. Gauge-fixed operators are a different construction: their meaning requires the stated gauge prescription, and gauge-dependent overlaps should not be described as gauge-invariant matrix elements.

    Gradient flow is different again. Its flow parameter is an additional smoothing coordinate, not the Euclidean source-sink separation. The usual four-dimensional gauge flow smooths in temporal as well as spatial directions. Its flowed observables are well-defined objects to study, but a flowed insertion with support across neighboring times is not automatically a single-slice operator in the transfer formula above. The heat-kernel smoothing and flow equation are explicit in Lüscher, Eqs. (1.1)–(1.4) and (2.18), printed pp. 1–2 and 5, PDF. Purely spatial operator smearing retains the time-slice construction used here.

    A composite basis on two sites

    Use the interacting model already defined in finite-time correlators: Nt=16N_t=16, two periodic spatial sites, m2=1/4m^2=1/4, λ=1/5\lambda=1/5, and both spacings one. Let

    Q=(φ0+φ1)/2,R=(φ0−φ1)/2.Q=(\varphi_0+\varphi_1)/\sqrt2, \qquad R=(\varphi_0-\varphi_1)/\sqrt2.

    The slice potential is even separately in QQ and RR. Spatial interchange sends R↦−RR\mapsto-R while leaving QQ fixed. The basis

    O=(Q,Q3,QR2)\boldsymbol O=(Q,Q^3,QR^2)

    is odd under global field reflection and even under interchange; it has zero total spatial momentum. It can access more than one state in this channel. Its exact ensemble means vanish by symmetry, so we do not subtract noisy measured means from its correlator matrix.

    Consider the explicitly defined two-site average

    ψ0=φ0+αφ11+α,ψ1=φ1+αφ01+α,0≤α≤1.\psi_0=\frac{\varphi_0+\alpha\varphi_1}{1+\alpha}, \qquad \psi_1=\frac{\varphi_1+\alpha\varphi_0}{1+\alpha}, \qquad 0\leq\alpha\leq1.

    This is a simple scalar stencil, with no gauge links. Put c=(1−α)/(1+α)c=(1-\alpha)/(1+\alpha). Then ψ0,1=(Q±cR)/2\psi_{0,1}=(Q\pm cR)/\sqrt2. Their normalized elementary sum (ψ0+ψ1)/2(\psi_0+\psi_1)/\sqrt2 is always QQ, but their projected cubic composite is

    Bα=ψ03+ψ132=12Q3+32c2QR2.B_\alpha=\frac{\psi_0^3+\psi_1^3}{\sqrt2} =\frac12Q^3+\frac32c^2QR^2.

    The two odd powers of RR cancel; the R2R^2 term survives with a tunable coefficient. This is a genuine change of an operator at fixed quantum numbers. α=0\alpha=0 gives the local cubic summed over sites; α=1\alpha=1 first averages the field completely and then cubes it. Interchanging these operations changes the observable.

    Let bα=(0,1/2,3c2/2)Tb_\alpha=(0,1/2,3c^2/2)^{\mathsf T}. Its measured correlator is bαTC(t)bαb_\alpha^{\mathsf T}C(t)b_\alpha, using the full matrix measured on each configuration. Cubing the separately averaged QQQQ correlator would be a different estimator and, in this interacting theory, not even an exact Gaussian identity.

    Measure overlap and usable time separation separately

    Direct transfer-operator quadrature provides vacuum amplitudes za(n)z_a^{(n)} and the full thermal reference. Let ∣1⟩|1\rangle denote the lowest state in the selected odd-QQ, even-RR channel. Define the vacuum ground-state fraction of BαB_\alpha by

    F1(α)=∣⟨0∣Bα∣1⟩∣2⟨0∣Bα2∣0⟩.F_1(\alpha)=\frac{|\langle0|B_\alpha|1\rangle|^2} {\langle0|B_\alpha^2|0\rangle}.

    The vacuum expectation of BαB_\alpha is zero, so the denominator is the sum of its squared overlaps over this entire channel. This fraction is invariant under rescaling the operator. It is a property of the vacuum state, not a finite-temperature occupation probability.

    For the frozen choices α=0,1/2,1\alpha=0,1/2,1, the ground fractions are 0.6638690.663869, 0.6163690.616369 and 0.6064650.606465. Stronger smearing makes this fraction smaller. It suppresses the QR2QR^2 part, which contributes substantial lowest-state overlap. Even in the free limit, R2R^2 contains its vacuum expectation as well as a two-quantum excitation, so eliminating it need not improve the ground-state projection.

    To connect overlaps with accessible time separations, define the dimensionless cosh effective energy

    Eeff(t)=arcosh⁡C(t−1)+C(t+1)2C(t).E_{\rm eff}(t)=\operatorname{arcosh} \frac{C(t-1)+C(t+1)}{2C(t)}.

    For a single cosh it equals the gap. For a mixture it is a diagnostic, not an independent eigenvalue. The table compares the exact thermal quantity with the actual common path ensemble at the preselected time t=3t=3:

    α\alphaVacuum fraction F1F_1Thermal Eeff(3)E_{\rm eff}(3)Measured Eeff(3)E_{\rm eff}(3)
    00.6638690.5797250.57080±0.002880.57080\pm0.00288
    1/21/20.6163690.5928870.58658±0.003420.58658\pm0.00342
    10.6064650.5949940.58913±0.003530.58913\pm0.00353

    The lowest transfer gap is 0.54166962580.5416696258. Even the exact effective energies at t=3t=3 have not reached it: the unsmeared cubic differs by about 7%7\%. At t=1t=1 its exact effective energy is 0.8678150.867815, while that of the fully averaged cubic is 0.9053810.905381. Reducing the field's spatial variation has not produced an earlier single-state window in this example.

    Stronger two-site cubic smearing reduces the exact ground-state fraction and leaves larger early-time effective energies; measured points carry replica-jackknife errors.

    Left: vacuum fractions from the interacting transfer reference. Right: exact finite-time effective energies (colored lines) and actual ensemble estimates at the fixed times 1, 2 and 3 (points with replica-jackknife errors); tiny horizontal offsets separate markers. The dashed line is the lowest transfer gap. All curves use the same action, temporal extent and operator definitions. Neither a visually approaching curve nor the error bars establish a fit plateau.

    The means use the same 16 independent chains as the preceding article. For each deleted replica, we recompute the ensemble correlator and then the nonlinear effective energy. All 16 resamples are defined at the stated times; none is clipped or dropped. The α=0\alpha=0, t=3t=3 value lies about 3.13.1 of these estimated standard errors below the reference. That discrepancy is retained, not removed by choosing another time or increasing the run after looking at it. Replica errors themselves are estimated from only 16 streams; block-size and start-group diagnostics are saved separately. These correlated comparisons demonstrate the sampling limitations as well as the operator dependence.

    A larger basis can form linear combinations to suppress selected unwanted overlaps. However, taking three BαB_\alpha values does not provide three independent operators: they all lie in the span of Q3Q^3 and QR2QR^2. Adding QQ gives the three-dimensional basis used in the generalized eigenvalue analysis. Statistical conditioning, omitted states and thermal transitions still have to be checked there.

    Summary

    An interpolator specifies a symmetry channel and a set of spectral overlaps. Spatial smearing can change those overlaps while leaving the measure fixed, but an elementary zero-momentum average may be unchanged exactly. Composite operators avoid that degeneracy. The two-site calculation supplies an explicit counterexample to the claim that more smoothing always improves the ground-state signal; both overlap fractions and measured time dependence must be assessed.

    Exercises

    Three smearings, only two operators

    Show that B0,B1/2,B1B_0,B_{1/2},B_1 are linearly dependent on every configuration. What happens to their 3×33\times3 correlation matrix? Show that replacing B1/2B_{1/2} by QQ removes this algebraic dependence.

    Solution

    For α=1/2\alpha=1/2, c=1/3c=1/3. Thus

    B0=12Q3+32QR2,B1/2=12Q3+16QR2,B1=12Q3.B_0=\frac12Q^3+\frac32QR^2, \qquad B_{1/2}=\frac12Q^3+\frac16QR^2, \qquad B_1=\frac12Q^3.

    Consequently B1/2=B0/9+8B1/9B_{1/2}=B_0/9+8B_1/9. Every correlation matrix made from these exact measurements has the same null combination, so its rank is at most two even before taking an ensemble average. More samples cannot repair an exact dependence.

    The coefficient matrix for (Q,B0,B1)(Q,B_0,B_1) in the basis (Q,Q3,QR2)(Q,Q^3,QR^2) has determinant −3/4-3/4, which is nonzero. These are independent polynomials on the continuous slice configuration space. Their equal-time Gram matrix is positive definite under a density positive on an open set: a nonzero linear combination cannot vanish almost everywhere. This does not guarantee a well-conditioned noisy matrix at another separation, nor that three states can be resolved with the available statistics.

    Remove a vacuum overlap in the free two-mode theory

    Set λ=0\lambda=0 and take infinite temporal extent. The independent modes have gaps EQ=2arsinh⁡(m/2)E_Q=2\operatorname{arsinh}(m/2) and ER=2arsinh⁡(m2+4/2)E_R=2\operatorname{arsinh}(\sqrt{m^2+4}/2), and variances vQ=1/(2sinh⁡EQ)v_Q=1/(2\sinh E_Q) and vR=1/(2sinh⁡ER)v_R=1/(2\sinh E_R). Find η\eta so that B~α=Bα−ηQ\widetilde B_\alpha=B_\alpha-\eta Q has no vacuum-to-one-QQ overlap, and compute its vacuum correlator.

    Solution

    Normal order separately in the two independent oscillators:

    Q3=:Q3:+3vQQ,QR2=Q:R2:+vRQ.Q^3={:Q^3:}+3v_QQ, \qquad QR^2=Q{:R^2:}+v_RQ.

    The required coefficient and remaining operator are

    η=32(vQ+c2vR),B~α=12:Q3:+32c2Q:R2:.\eta=\frac32(v_Q+c^2v_R), \qquad \widetilde B_\alpha=\frac12{:Q^3:}+\frac32c^2Q{:R^2:}.

    The two terms create orthogonal oscillator states, respectively three QQ quanta and one QQ plus two RR quanta. Their vacuum norms are 3!vQ33!v_Q^3 and 2!vQvR22!v_Qv_R^2. Therefore

    ⟨B~α(t)B~α(0)⟩vac=32vQ3e−3EQt+92c4vQvR2e−(EQ+2ER)t.\langle\widetilde B_\alpha(t)\widetilde B_\alpha(0)\rangle_{ \rm vac} =\frac32v_Q^3e^{-3E_Qt} +\frac92c^4v_Qv_R^2e^{-(E_Q+2E_R)t}.

    At α=1\alpha=1, c=0c=0 and the second contribution disappears: after the separate vacuum subtraction this operator creates only the three-QQ level. This is a controlled improvement for that excited target, unlike the ground-state comparison above. At finite temporal extent, vacuum normal ordering does not remove all thermally occupied transitions; the full trace is required again.

    References

    • Michele Della Morte, Benjamin Jäger, Thomas D. Rae and Hartmut Wittig, Improved interpolating fields for hadrons at non-zero momentum, European Physical Journal A 48, 139 (2012), arXiv:1208.0189, §§1–2, Eqs. (2)–(5). Spatial hopping kernels and anisotropic Wuppertal smearing; backward links are translated above.
    • Rajan Gupta, Introduction to Lattice QCD, Les Houches lectures (1998), arXiv:hep-lat/9807028, §17.2 and Table 8. Hadronic interpolating fields and quantum numbers.
    • Martin Lüscher, Properties and uses of the Wilson flow in lattice QCD, Journal of High Energy Physics 2010(08), 071, arXiv:1006.4518, Eqs. (1.1)–(1.4) and (2.18). The additional flow coordinate and smoothing kernel.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.