Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    A plaquette measures the failure of parallel transport around a small square to return a color vector unchanged. Squaring that small curvature should reproduce the Yang–Mills action. The Wilson action implements this idea using a real trace of the exact group-valued plaquette. The normalization depends on the representation, the spacings, and whether the gauge coupling is inside the connection.

    Preparation: Forward links and Haar integration, Taylor expansion and the leading Baker–Campbell–Hausdorff formula. We use Hermitian generators, Dμ=∂μ−ig0AμD_\mu=\partial_\mu-ig_0A_\mu, and the fundamental SU(N) trace tr⁡(TaTb)=δab/2\operatorname{tr}(T^aT^b)=\delta^{ab}/2.

    From a small square to the field strength

    Take an isotropic Euclidean lattice with spacing aa. Forward links transport from xx to x+μ^x+\hat\mu with phase +ig0∫A+ig_0\int A. The positively oriented plaquette based at xx is

    Pμν(x)=Vν†(x)Vμ†(x+ν^)Vν(x+μ^)Vμ(x).P_{\mu\nu}(x)=V_\nu^\dagger(x)V_\mu^\dagger(x+\hat\nu) V_\nu(x+\hat\mu)V_\mu(x).

    For a smooth field, the derivative part of its expansion comes from the displaced links: the ν\nu link contributes ig0a2∂μAνig_0a^2\partial_\mu A_\nu, and the reversed μ\mu link contributes −ig0a2∂νAμ-ig_0a^2\partial_\nu A_\mu. To determine the non-Abelian sign independently, hold both potentials constant and put X=ig0aAμX=ig_0aA_\mu, Y=ig0aAνY=ig_0aA_\nu. Then

    e−Ye−XeYeX=1+[Y,X]+O(a3)=1+g02a2[Aμ,Aν]+O(a3).e^{-Y}e^{-X}e^Ye^X=1+[Y,X]+O(a^3) =1+g_0^2a^2[A_\mu,A_\nu]+O(a^3).

    Combining the terms gives

    Pμν(x)=1+ig0a2Fμν(x)+O(a3),Fμν=∂μAν−∂νAμ−ig0[Aμ,Aν].P_{\mu\nu}(x)=1+ig_0a^2F_{\mu\nu}(x)+O(a^3),\qquad F_{\mu\nu}=\partial_\mu A_\nu-\partial_\nu A_\mu-ig_0[A_\mu,A_\nu].

    There is no sum over μ,ν\mu,\nu in this equation. The O(a3)O(a^3) part includes derivative and transport corrections at the chosen corner. Since the plaquette is unitary, write its near-identity logarithm as iHiH with Hermitian H=g0a2F+O(a3)H=g_0a^2F+O(a^3). Expanding its real trace yields

    1−1NRe⁡tr⁡Pμν=g02a42Ntr⁡Fμν2+O(a5)=g02a44N∑a(Fμνa)2+O(a5).1-\frac1N\operatorname{Re}\operatorname{tr}P_{\mu\nu} =\frac{g_0^2a^4}{2N}\operatorname{tr}F_{\mu\nu}^2+O(a^5) =\frac{g_0^2a^4}{4N}\sum_a(F_{\mu\nu}^a)^2+O(a^5).

    This argument fixes the sign even when all derivatives vanish. It also explains why the trace action has no term linear in curvature. Formulas written with backward links require the adjoint and field translation before comparing their ordered products.

    Match one independent plaquette per plane

    Define the fundamental Wilson action by

    SW=β∑x∑μ<ν(1−1NRe⁡tr⁡Pμν(x)).S_W=\beta\sum_x\sum_{\mu<\nu} \left(1-\frac1N\operatorname{Re}\operatorname{tr}P_{\mu\nu}(x)\right).

    Here β\beta is the lattice coupling. The sum uses each unoriented elementary square once, and the added constant makes SW=0S_W=0 on identity links. The target is

    SE=14∫ddx∑μ,ν,a(Fμνa)2=12∫ddx∑μ<ν,a(Fμνa)2.S_E=\frac14\int\mathrm d^d x\sum_{\mu,\nu,a}(F_{\mu\nu}^a)^2 =\frac12\int\mathrm d^d x\sum_{\mu<\nu,a}(F_{\mu\nu}^a)^2.

    Using ∑x≃a−d∫ddx\sum_x\simeq a^{-d}\int\mathrm d^d x, the coefficient of the latter sum in SWS_W is βg02a4−d/(4N)\beta g_0^2a^{4-d}/(4N). Thus

    β=2Nad−4g02.\boxed{\beta=\frac{2Na^{d-4}}{g_0^2}.}

    The canonical coupling has mass dimension (4−d)/2(4-d)/2, so this expression is dimensionless. In four dimensions it reduces to 2N/g022N/g_0^2. The plaquette construction and four-dimensional normalization are the Wilson-action result presented in Tong, §4.2.1, Eq. (4.9), printed p. 209, PDF. The factor of two is fixed by the difference between μ<ν\mu<\nu and a sum over both orders.

    An alternative convention absorbs the coupling into A=g0A\mathscr A=g_0A, so that F=g0F\mathscr F=g_0F and the target action reads ∫tr⁡FμνFμν/(2g02)\int\operatorname{tr}\mathscr F_{\mu\nu}\mathscr F_{\mu\nu}/(2g_0^2). The anti-Hermitian convention uses A=−iA\mathcal A=-i\mathscr A and F=−iF\mathcal F=-i\mathscr F, giving the compensating minus sign in −∫tr⁡F2/(2g02)-\int\operatorname{tr}\mathcal F^2/(2g_0^2). One must not keep both an explicit 1/g021/g_0^2 in the action and an extra unaccounted coupling inside the same curvature.

    For smooth fields on a periodic lattice, the integrated leading bulk discretization errors are O(a2)O(a^2). The apparent O(a)O(a) relative term in the corner expansion shifts the location at which the curvature density is sampled; its first integrated contribution is a total derivative. Equivalently a plaquette-centered expansion removes that odd displacement. Boundaries require their own treatment. The classical smooth-field expansion fixes the normalization and the leading discretization error. Bare parameters must still be matched along an appropriate continuum trajectory.

    U(1) fixes the charge normalization separately

    For a unit-charge U(1) field, use Vμ=eie0∫AV_\mu=e^{ie_0\int A} and P=eiθμνP=e^{i\theta_{\mu\nu}}. The trace is one-dimensional, and its generator has square one, not the SU(N) fundamental index 1/21/2. Therefore

    SU(1)=β∑x,μ<ν(1−cos⁡θμν),β=ad−4e02.S_{U(1)}=\beta\sum_{x,\mu<\nu}(1-\cos\theta_{\mu\nu}),\qquad \beta=\frac{a^{d-4}}{e_0^2}.

    This is not obtained by setting N=1N=1 in the SU(N) formula. In two dimensions with spacings ax,aτa_x,a_\tau,

    θxτ=e0axaτFxτ+⋯ ,β=1e02axaτ,SE=12∫dx dτ Fxτ2.\theta_{x\tau}=e_0a_xa_\tau F_{x\tau}+\cdots,\qquad \beta=\frac{1}{e_0^2a_xa_\tau},\qquad S_E=\frac12\int\mathrm dx\,\mathrm d\tau\,F_{x\tau}^2.

    This is the normalization used by the chapter's open two-dimensional ensemble. Its compact link angles are integrated over their full circles. Replacing every cosine by a quadratic is a small-plaquette expansion, not an identity for that ensemble.

    A smooth periodic-field check

    On a 2π×2π2\pi\times2\pi torus choose e0=1e_0=1, Ax=0A_x=0 and Aτ(x)=csin⁡xA_\tau(x)=c\sin x, with c=0.4c=0.4 in the chosen length units. Exact link integrals give

    Vx=1,Vτ(x)=eiaτcsin⁡x,θxτ(x)=aτc[sin⁡(x+ax)−sin⁡x].V_x=1,\qquad V_\tau(x)=e^{ia_\tau c\sin x},\qquad \theta_{x\tau}(x)=a_\tau c[\sin(x+a_x)-\sin x].

    The continuum field strength is ccos⁡xc\cos x and its action is SE=c2π2=1.5791367042S_E=c^2\pi^2=1.5791367042. The retained algebra_checks.py multiplies the four links around each plaquette and evaluates the Wilson action. For Nx=Nτ=NN_x=N_\tau=N it gives:

    NNSWS_WSW/SES_W/S_E
    81.49420323450.9462152520
    161.55858121110.9869830819
    321.57404650850.9967765959
    641.57786729940.9991961401

    The leading relative error decreases by a factor approaching four when aa halves. Independently summing 2sin⁡2(θxτ/2)2\sin^2(\theta_{x\tau}/2) checks the cancellation-sensitive 1−Re⁡P1-\operatorname{Re}P evaluation. Rectangular 32×1632\times16 and 32×6432\times64 grids check the axaτa_xa_\tau coefficient as well.

    The companion also uses constant SU(2) potentials A1=σ1/2A_1=\sigma_1/2, A2=σ2/2A_2=\sigma_2/2, g0=1g_0=1. Their curvature is F12=σ3/2F_{12}=\sigma_3/2. Direct matrix exponentials give (P−P†)/(2ia2)→F12(P-P^\dagger)/(2ia^2)\to F_{12}, while the plaquette action divided by a4/8a^4/8 tends to one. This check detects a commutator-sign mistake that the Abelian configuration cannot.

    Separate spatial and temporal spacings

    For d−1d-1 spatial dimensions with spacing asa_s and one Euclidean time direction with spacing aτa_\tau, define ξ=as/aτ\xi=a_s/a_\tau. Use independent coefficients

    SW=βs∑x,i<j(1−1NRe⁡tr⁡Pij)+βτ∑x,i(1−1NRe⁡tr⁡Piτ).S_W=\beta_s\sum_{x,i<j}\left(1-\frac1N\operatorname{Re}\operatorname{tr}P_{ij}\right) +\beta_\tau\sum_{x,i}\left(1-\frac1N\operatorname{Re}\operatorname{tr}P_{i\tau}\right).

    A spatial plaquette has area as2a_s^2 and a temporal plaquette has area asaτa_sa_\tau, while the cell volume is asd−1aτa_s^{d-1}a_\tau. Matching each independent F2/2F^2/2 term gives the tree-level values

    βs=2Ng02aτasd−5=β0ξ,βτ=2Ng02asd−3aτ=β0ξ,β0=2Nasd−4g02.\beta_s=\frac{2N}{g_0^2}a_\tau a_s^{d-5}=\frac{\beta_0}{\xi},\qquad \beta_\tau=\frac{2N}{g_0^2}\frac{a_s^{d-3}}{a_\tau}=\beta_0\xi,\qquad \beta_0=\frac{2Na_s^{d-4}}{g_0^2}.

    When there is only one spatial direction there are no ijij plaquettes, so only the temporal coefficient is needed. At fixed asa_s, sending aτ→0a_\tau\to0 makes temporal plaquettes stiff while each spatial action contribution is proportional to the elapsed time. This is the scaling needed for a Hamiltonian limit; obtaining the Hamiltonian still requires the transfer operator and its electric-field normalization.

    These are classical matching relations. In an interacting quantum theory, a bare anisotropy parameter need not equal the ratio of physical spatial and temporal scales. That ratio must be calibrated from observables before interpreting a measured energy as a physical one.

    The representation is part of the regulator

    Suppose the plaquette trace is taken in a representation RR of dimension dRd_R and index T(R)T(R), defined by tr⁡R(TaTb)=T(R)δab\operatorname{tr}_R(T^aT^b)=T(R)\delta^{ab}. Its expansion is

    1−1dRRe⁡tr⁡RP=g02a4T(R)2dR∑a(Fμνa)2+⋯ .1-\frac1{d_R}\operatorname{Re}\operatorname{tr}_R P =\frac{g_0^2a^4T(R)}{2d_R}\sum_a(F_{\mu\nu}^a)^2+\cdots.

    Thus a pure RR plaquette action matches the canonical kinetic term with

    βR=dRad−4g02T(R).\beta_R=\frac{d_Ra^{d-4}}{g_0^2T(R)}.

    The leading local curvature term does not specify the whole lattice theory. An adjoint trace, for example, cannot distinguish two fundamental plaquettes differing by a center element. The integration group, allowed line observables, global sectors and finite-spacing action must be stated along with this perturbative normalization. Adding representations or larger loops can alter lattice artifacts and phase structure while leaving the same quadratic continuum term.

    Summary

    The Wilson action sums the departure of a plaquette's real normalized trace from one. Its continuum coefficient follows from three inputs: the plaquette area, the cell volume, and the generator trace. Those inputs give β=2Nad−4/g02\beta=2Na^{d-4}/g_0^2 for fundamental SU(N), a different unit-charge U(1) coefficient, and separate spatial and temporal couplings on an anisotropic lattice. Smooth-field tests verify these normalizations.

    Exercises

    Fundamental and adjoint terms together

    In four-dimensional SU(2), combine fundamental and adjoint plaquette terms with coefficients bF,bAb_F,b_A. Use dF=2d_F=2, T(F)=1/2T(F)=1/2, dA=3d_A=3 and T(A)=2T(A)=2 to find the tree-level relation to the canonical g0g_0. Why does matching this relation not make the two pure actions identical?

    Solution

    Each coefficient contributes g02bRT(R)/(2dR)g_0^2b_RT(R)/(2d_R) to an independent FμνaFμνaF^a_{\mu\nu}F^a_{\mu\nu} term. Matching to 1/21/2 gives

    bF4+2bA3=1g02.\frac{b_F}{4}+\frac{2b_A}{3}=\frac1{g_0^2}.

    Thus the pure fundamental action uses bF=4/g02b_F=4/g_0^2, while the pure adjoint action uses bA=3/(2g02)b_A=3/(2g_0^2). These are equalities of their leading smooth-field terms. For a plaquette P=−1P=-\mathbf1 the fundamental normalized trace is −1-1 and costs 2bF2b_F. Its adjoint matrix is the identity and costs zero. The actions assign different weights to a perfectly valid compact configuration, despite agreeing to quadratic order near P=1P=\mathbf1. Specifying the global gauge group and allowed observables is also necessary.

    Detect a mistuned time spacing

    Suppose a four-dimensional lattice has ξ=as/aτ=2\xi=a_s/a_\tau=2, but uses equal spatial and temporal plaquette coefficients. Find the ratio of the resulting continuum ∑i(Fiτa)2\sum_i(F_{i\tau}^a)^2 coefficient to the ∑i<j(Fija)2\sum_{i<j}(F_{ij}^a)^2 coefficient. How should the two lattice coefficients be related instead?

    Solution

    Dividing the two plaquette-area squares by the common cell volume gives spatial coefficient g02βsξ/(4N)g_0^2\beta_s\xi/(4N) and temporal coefficient g02βτ/(4Nξ)g_0^2\beta_\tau/(4N\xi). Their ratio is

    βτβsξ2.\frac{\beta_\tau}{\beta_s\xi^2}.

    Equal lattice coefficients therefore give 1/41/4, so the Euclidean electric and magnetic terms have unequal physical normalization. Matching requires βτ/βs=ξ2=4\beta_\tau/\beta_s=\xi^2=4, with their overall values fixed by the target coupling. One could reinterpret a mistuned action using a different time coordinate, but then its actual physical anisotropy would differ from the stipulated one. Quantum calibration can require further tuning.

    References

    • D. Tong, Gauge Theory, graduate lecture notes (2018), Chapter 4, PDF, §4.2.1, printed pp. 207–209. The continuum coefficient is derived here with the site's forward-link convention.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.