Spectral Weights and Real-Time Response from a Truncated Hamiltonian
A list of energies does not tell us how strongly a probe excites each state. The missing information is in operator matrix elements. Together, energies and matrix elements determine finite-volume spectral peaks, time correlators and linear response—and expose truncation errors that an energy comparison alone can miss.
We will calculate these quantities for the spatially averaged field in the chapter's interacting scalar model. Direct time evolution and sum rules provide checks, while a deliberately smoothed spectrum shows why a plotting width must not be interpreted as a decay rate.
Preparation: The scalar Fock Hamiltonian and its field parity, and Renormalized Truncated Hamiltonians for the normalized variational map used below.
Specify both the Hamiltonian and the probe
Use the same periodic scalar, with , and multiplying without a . The infinite-line mass- ordering is represented on the circle by
where and . The additive constant cancels from every energy difference used here.
The Hermitian probe is the spatial average
It has zero momentum, is even under spatial reflection and odd under field parity. Thus it connects the reflection-even, field-even ground state to the reflection-even, field-odd sector. Restricting to those sectors loses no states in this particular correlator.
For raw total-energy truncation, use and . For the normalized graph construction, the trial states are with , and the matching matrices are
Between field parities, the latter means . The large finite reference has cutoff , with retained as a separate sensitivity check. Smaller cutoffs are , , and . No eigenvalue or operator is fitted to a target level.
Insert a complete set of finite-space states
Let be the normalized even ground state of the chosen matrix, its odd eigenstates, and
Parity gives . Inserting the identity in the odd sector yields the Wightman correlator
The corresponding positive-frequency measure is
There is no in this definition. With the site Fourier and retarded conventions, the commutator spectral function is instead
It is odd, and is nonnegative as a measure. A finite spatial volume has discrete physical levels; a finite basis makes the number of retained peaks finite as well. A peak's location and weight answer different questions, and both need cutoff tests.
Get the response sign from the source
The retarded correlator is
Couple a source by , so the Hamiltonian perturbation is . A spatially uniform source density is . First-order evolution gives
In particular, a positive impulse applies the unitary to the state. Its initial response has the positive sign in . These conventions agree with Kovtun, §§2.2–2.3, printed pp. 18–21 (PDF), with our expectation values taken in the ground state rather than a thermal ensemble.
Fourier transformation of Eq. (5) gives
so . The zero-frequency susceptibility is
Here denotes frequency zero. There are no source-dependent operator or contact terms for this specified linear probe. A current or metric probe can require additional terms; Eq. (7) should not be transferred to it without checking its source definition.
Sum rules distinguish missing states from algebra errors
Completeness in the matrix space gives
The same identities hold with replaced by the graph matrices. To derive the second one, expand the double commutator as and let act on the ground state on the left and right. The result is .
These exact matrix identities are useful checks, but they are not the full canonical sum rules. Before energy projection, the field potential commutes with the uniform coordinate. Its kinetic term gives
A total-energy projection generally changes the commutator. Its deviation from must be measured, rather than assumed away because Eq. (8) passes.
There is also a distinction at equal time. The true projected operator includes paths through states outside , whereas does not:
The calculation evaluates the zero-mode square before compressing it, then compares its ground-state expectation with the spectral zeroth moment. For the graph, use in the first expression. Even the finite reference can miss weight when a single action of leaves its energy cutoff.
Matched spectral weights and remaining reference dependence
Selected results from the actual interacting matrices are:
| Approximation | Lowest odd gap | Lowest peak weight | |
|---|---|---|---|
| Raw, cutoff | |||
| Graph, cutoff | |||
| Graph, cutoff | |||
| Reference, cutoff |
The graph calculation improves these quantities relative to that finite reference. Nevertheless, the reference at cutoff has gap , weight and susceptibility . Its change to cutoff exceeds some graph-versus-reference differences in the table. The table is not a set of continuum predictions with the displayed last digits as physical error bounds.
Consistent operator transformation matters too. At graph cutoff , using the bare low-space operator with the graph eigenstates changes the lowest weight from to . The numerical effect is modest here; the normalization and omitted high-space matrix elements have not become optional.
The canonical first-moment target is . Raw cutoff gives , graph cutoff gives , and the cutoff- reference gives . Improvement is not automatic for every diagnostic: at cutoff , the graph value is farther from the target than the raw value .
At graph cutoff , the spectral zeroth moment is , while the true transformed expectation is . Their positive difference, , is missing spectral weight of the type in Eq. (10). The cutoff- reference still has a smaller positive deficit, approximately .
Check the time signal without summing eigenstate phases
For a separate numerical evaluation of Eq. (3), form and apply a matrix exponential directly:
The companion uses an exponential-action algorithm on the odd-sector matrix, independently of its spectral decomposition. For every displayed approximation and both references, the two evaluations agree within on . This checks the numerical propagation and spectral assembly for the same finite Hamiltonian; it is not an independent continuum calculation.
The impulse check is more sensitive to the response sign. At graph cutoff , evolve with the full even-plus-odd Hamiltonian and divide the difference of the resulting means by . The maximum deviation from is for and for . The factor of four is consistent with the symmetric finite-source error being quadratic in .
A static check diagonalizes and differentiates the field mean. At , it gives , within of Eq. (7). Finally, setting in the actual Fock matrices recovers the one-pole result
to in the retained check. This fixes the field-average normalization independently of an interacting fit.
Smearing is a resolution choice
A delta spectrum cannot be drawn as an ordinary curve. For illustration, replace each delta by a normalized Gaussian,
The numerical output retains all original gaps and weights. The chosen widths and are display resolutions. The Gaussian is normalized on the entire real line; a plot restricted to omits its small negative-frequency tail. For a smeared commutator function, use to preserve oddness.
The same , , Hamiltonian and averaged-field operator determine both panels. Gaussian spectral widths are chosen for display and are not decay rates. The time response is calculated from the unsmeared weights. The reference has energy cutoff , with its separate cutoff sensitivity retained in the text and numerical output.
At fixed finite volume and cutoff, these signals are sums of phases and can recur. Smoothing a plotted spectrum cannot establish irreversible damping. Conversely, a small energy error can accumulate a phase error of order , so agreement at short times does not establish long-time accuracy.
A useful sequence is to converge the basis at fixed volume and fixed time or resolution, test the larger-reference dependence, and only then investigate increasing volume. If a continuum spectral density is sought, the resolution must also be compared with the shrinking finite-volume level spacing. The limits of cutoff, volume, resolution and time answer different questions and cannot be silently interchanged.
The lowest peak can be a sharper test than the gap alone. At cutoff the raw gap is above the cutoff- reference, while the static susceptibility is below it. Each higher odd state contributes to the susceptibility, so matching one gap cannot fix the measured response. A different finite experiment reads a Schwinger-model correlator on a qubit register. Its resolution kernel comes from a finite series of sampling times. Here each weight was obtained directly from an eigenvector before a display width was chosen.
Summary
Spectral weights turn energies into correlators and response functions. Consistently transformed operators, direct propagation, canonical sum rules and source checks test different parts of the calculation. The finite scalar example improves low peaks with a graph basis while retaining reference drift and missing-weight diagnostics. Finite spectral peaks and plotting widths do not by themselves describe decay in an infinite system.
Exercises
1. Recover the free averaged-field response. For a frequency- zero oscillator, use Eq. (1) to find its spectral weight, zeroth and first moments, retarded correlator and static susceptibility. Check the static answer by completing the square in a source .
Solution
Only the one-quantum state is created from the vacuum. Its gap is and its weight is , so
Equation (5) gives , and Eq. (7) gives . Writing , the static Hamiltonian is
Its ground state has , confirming the positive physical susceptibility and the minus sign between and .
2. Smoothing creates apparent damping. Fourier transform the Gaussian measure in Eq. (11) over the full real frequency line. Find the change in its zeroth, first and second moments. Explain why the resulting time envelope is not evidence for a physical relaxation rate.
Solution
For each peak,
Thus . Gaussian normalization and its zero centered mean preserve and , while its variance adds
These are full-real-line integrals; discarding the negative-frequency Gaussian tails changes them. At any nonzero display width the envelope suppresses late times even for a single exactly stable oscillator. Taking before therefore gives a different visual conclusion from removing the smoothing first. The suppression was introduced by the resolution kernel, not by the Hamiltonian dynamics.
References
- P. Kovtun, “Lectures on Hydrodynamic Fluctuations in Relativistic Theories,” Journal of Physics A 45 (2012) 473001, arXiv:1205.5040 (PDF). §§2.2–2.3, printed pp. 18–21, define the source response, retarded correlator and spectral conventions; the finite ground-state sums here are derived explicitly.
- S. Rychkov and L. G. Vitale, “Hamiltonian Truncation Study of the Theory in Two Dimensions,” Physical Review D 91 (2015) 085011, arXiv:1412.3460v6 (PDF). §2 defines the scalar Hamiltonian used for the numerical example; §§3.1–3.3 explain its truncation corrections.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.