Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Scale Setting and Lines of Constant Physics

    A lattice calculation may report a mass as aM=0.2aM=0.2. That number does not say whether the mass is 1 eV or 1 GeV. A dimensionful input sets the overall scale; ratios computed by the theory predict other quantities. The same input also carries statistical, finite-volume and cutoff effects into the final result.

    Preparation: Continuum tuning and elementary propagation of correlated errors.

    From lattice numbers to units

    Let A=aMA=aM and B=aXB=aX be two dimensionless masses extracted with the same lattice spacing, and let M∗M_* be the chosen physical input for the first mass. Then

    aM=AM∗,Xlat=BaM=M∗BA.a_M=\frac{A}{M_*},\qquad X^{\rm lat}=\frac B{a_M}=M_*\frac BA.

    The final expression makes the prediction particularly clear: the computed quantity is R=B/AR=B/A, and M∗M_* supplies its units. The input observable cannot simultaneously count as a successful prediction. This ratio-based formulation is explained in Sommer, §1, Eqs.(1)–(4).

    For a toy scalar theory, M∗M_* may simply be a definition of the unit of energy. When comparing a theory with experiment, the input must refer to the same physical theory and observable. Omitting electromagnetism or changing the matter content, for example, changes what matching to an experimental mass means.

    A length input works similarly. If ℓ^=ℓ/a\widehat\ell=\ell/a, then aℓ=ℓ∗/ℓ^a_\ell=\ell_*/\widehat\ell. A flow observable can define a useful length after its relation to a dimensionful input is established. A precisely measured dimensionless scale does not create physical units by itself.

    A correlated numerical example

    Consider the following synthetic measurements, chosen to demonstrate error propagation rather than represent an ensemble:

    A=0.200±0.002,B=0.350±0.004,Corr⁡(A,B)=0.8.A=0.200\pm0.002,\qquad B=0.350\pm0.004,\qquad \operatorname{Corr}(A,B)=0.8.

    The same configurations often affect both fitted masses, so correlation is natural. For small errors, linearizing R=B/AR=B/A gives

    Var⁡(R)=σB2A2+B2σA2A4−2BCov⁡(A,B)A3.\operatorname{Var}(R)= \frac{\sigma_B^2}{A^2} +\frac{B^2\sigma_A^2}{A^4} -\frac{2B\operatorname{Cov}(A,B)}{A^3}.

    Here R=1.750R=1.750 and σR=0.01209\sigma_R=0.01209. Discarding the positive correlation gives 0.026580.02658, more than twice as large. Negative correlation could instead increase the ratio's error. Correlation has to be measured or specified, not chosen to make the uncertainty smaller.

    Take an independent input M∗=500±5M_*=500\pm5 MeV. This gives

    aM=(4.000±0.0566)×10−4 MeV−1,Xlat=875.0±10.64 MeV.\begin{aligned} a_M&=(4.000\pm0.0566)\times10^{-4}\ {\rm MeV}^{-1},\\ X^{\rm lat}&=875.0\pm10.64\ {\rm MeV}. \end{aligned}

    The prediction's variance is M∗2Var⁡(R)+R2σM∗2M_*^2\operatorname{Var}(R)+R^2\sigma_{M_*}^2 under the stated independence. The spacing's uncertainty is already correlated with BB; propagating errors from B/aMB/a_M as though they were independent would lose the covariance term.

    For actual correlator fits, resample common blocks of configurations and refit both masses on every jackknife or bootstrap sample. Form the ratio and the tuning observables inside that same resample. This preserves nonlinear correlations and uses the original independent information once. Linear propagation is a useful check when relative errors are small; it is unreliable for a denominator whose distribution approaches zero.

    Why two scale choices differ at finite spacing

    Suppose, schematically, that two measured masses satisfy

    A=aM[1+cM(aM)2+⋯ ],B=aX[1+cX(aM)2+⋯ ].A=aM\left[1+c_M(aM)^2+\cdots\right],\qquad B=aX\left[1+c_X(aM)^2+\cdots\right].

    Using the exact continuum value of MM as input gives

    Xlat=X[1+(cX−cM)(aM)2+⋯ ].X^{\rm lat}=X\left[1+(c_X-c_M)(aM)^2+\cdots\right].

    Thus a scale with substantial artifacts changes the apparent slope of every dimensionful result. Setting a scale does not remove its artifacts. Finite-volume shifts enter the ratio in the same way: at first order, the relative shift is δX(L)−δM(L)\delta_X(L)-\delta_M(L). A small difference can be a cancellation, not proof that either individual observable has negligible volume dependence. Sommer's §1.2 discusses precision and systematic effects as separate scale-selection criteria.

    Two reasonable scale choices should approach the same physical predictions after the relevant continuum, volume and parameter limits. At finite cutoff their discrepancy is useful diagnostic information. It should not be hidden by averaging the assigned spacings without a model of their correlations and artifacts.

    Follow a line of constant physics

    Changing a bare mass or coupling changes the theory as well as its ruler. An interacting line of constant physics therefore fixes enough dimensionless renormalized observables to identify the desired theory while the cutoff changes.

    For the two-dimensional scalar action with λ^φ4/24\widehat\lambda\varphi^4/24, the previous article gives an explicit finite-volume prescription: on a periodic square, tune z=N/ξ2z=N/\xi_2 and gR=−χ4/(χ22ξ22)g_R=-\chi_4/(\chi_2^2\xi_2^2) to selected values. Here ξ2\xi_2 is the specified second-moment length and the susceptibilities come from magnetization cumulants. The two conditions determine two bare parameters locally when their response matrix is nonsingular. The physical input L∗L_* then assigns a=L∗/Na=L_*/N; equivalently, setting ξ2,∗=L∗/z\xi_{2,*}=L_*/z gives the same scale.

    To implement the tuning, measure zz and gRg_R near a trial (m^02,λ^)(\widehat m_0^2,\widehat\lambda), estimate their derivatives with respect to those parameters, and solve the linear correction

    (δzδgR)=(∂m^02z∂λ^z∂m^02gR∂λ^gR)(δm^02δλ^).\begin{pmatrix}\delta z\\ \delta g_R\end{pmatrix} = \begin{pmatrix} \partial_{\widehat m_0^2}z & \partial_{\widehat\lambda}z\\ \partial_{\widehat m_0^2}g_R & \partial_{\widehat\lambda}g_R \end{pmatrix} \begin{pmatrix}\delta\widehat m_0^2\\ \delta\widehat\lambda\end{pmatrix}.

    The left side is target minus measured value. Check the new point with a fresh calculation; linear response is local. Derivatives can be estimated with nearby runs or covariance identities, for example

    ∂θ⟨O⟩=⟨∂θO⟩−Cov⁡(O,∂θS).\partial_\theta\langle O\rangle =\langle\partial_\theta O\rangle -\operatorname{Cov}(O,\partial_\theta S).

    For θ=m^02\theta=\widehat m_0^2, ∂θS=12∑nφn2\partial_\theta S=\tfrac12\sum_n\varphi_n^2; for θ=λ^\theta=\widehat\lambda, it is 124∑nφn4\tfrac1{24}\sum_n\varphi_n^4. Differentiate the constituent moments before forming the response of zz or gRg_R. This construction specifies how to tune the simulations at successive lattice spacings.

    A useful final observable is then a ratio not used in tuning, measured at fixed zz, gRg_R and geometry for several NN. Its residual variation is the subject of continuum and volume extrapolation.

    Carry the ratio through a complete scalar mass measurement. An exactly calibrated reference pole makes the horizontal spacings known there. The target energy is fitted from a separate correlator at each spacing.

    Summary

    A dimensionful input converts computed ratios into physical units. Its errors and regulator dependence propagate into other observables, usually with correlations. A line of constant physics specifies which renormalized quantities stay fixed before changing the spacing; scale setting alone does not accomplish that tuning.

    Exercises

    Perfect common fluctuations

    Suppose every resampled pair obeys B=2AB=2A exactly. What is the statistical uncertainty of B/AB/A? What happens if an independently uncertain M∗M_* sets the scale?

    Solution

    The ratio is exactly 2 in every sample, so its sampling variance is zero, even though both masses fluctuate. In linear propagation, σB=2σA\sigma_B=2\sigma_A and Cov⁡(A,B)=2σA2\operatorname{Cov}(A,B)=2\sigma_A^2, and the three terms cancel. The dimensionful prediction is X=2M∗X=2M_* and has uncertainty 2σM∗2\sigma_{M_*}. Common statistical cancellation cannot remove an independent uncertainty in the external input.

    Tuning with an action derivative

    For a parameter-independent observable O=∑nφn2O=\sum_n\varphi_n^2 in the scalar theory, determine the sign of ∂m^02⟨O⟩\partial_{\widehat m_0^2}\langle O\rangle at finite volume.

    Solution

    Differentiate the normalized finite integral. The derivative of its numerator inserts −12O-\tfrac12O, and the derivative of its denominator subtracts the disconnected contribution. Consequently

    ∂m^02⟨O⟩=−12(⟨O2⟩−⟨O⟩2)≤0.\partial_{\widehat m_0^2}\langle O\rangle =-\frac12\left(\langle O^2\rangle-\langle O\rangle^2\right)\le0.

    Increasing the mass coefficient suppresses the total squared field. This is an exact finite-volume check in the stable positive scalar measure, not an assertion that every fitted mass or coupling has an equally simple monotonicity property.

    References

    The synthetic error-propagation example is reproduced by examples/lattice-hamiltonian/lattice-fields/limits.py.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.