From a Lattice Correlator to a Continuum Mass
How do numbers measured at integer time separations give a particle mass in MeV? Start with the spatially averaged field on a finite periodic lattice. Its correlations decay in both directions around the Euclidean time circle. Fitting this decay gives an energy in lattice units. An independently calibrated reference pole sets the units, and repeating the fit at several spacings reveals the continuum limit.
Our free-field benchmark gives MeV from the three finest spacings in the larger box. The quoted error is statistical. The exact continuum answer of 400 MeV lets us test the entire procedure, including the size and sign of the lattice artifact. All eight measured correlators and their time covariances are available as a small data file.
Preparation. The free scalar lattice action supplies the dynamics. The finite-time trace explains periodic propagation, and the correlated fit introduces the statistical method.
Fix the theory, the ruler and the box
Use two decoupled real scalar fields in Euclidean dimensions. Each has the nearest-neighbour action on a periodic lattice with equal spacing in both directions. In natural units, and are lengths. Write for the dimensionless coefficient of the bare mass term. For either field the dimensionless inverse propagator is
The allowed momenta are and . At zero spatial momentum, continuing to the pole gives . The reference field has an exactly known pole. Assign it MeV and denote its value in lattice units by . This fixes . Set the target bare parameter to twice the reference value at every spacing:
Hold the vanishing interactions, this bare ratio and the reference pole in physical units fixed. In this Gaussian theory that trajectory approaches the same continuum mass ratio at every refinement. It is the example's line of constant physics. An interacting theory generally needs measured renormalized tuning conditions. The reference scale here carries no statistical or calibration error.
Use . Hold and repeat the calculation at and . For instance, in the larger box gives . The continuum prediction to check is the target mass, measured in units of the reference.
Measure the periodic correlator
Project the target field onto zero spatial momentum by taking on time slice . Average over all source times in each configuration:
The field has zero mean by reflection symmetry. The first scalar simulation measures a local field correlator averaged over axes; summing the spatial slice here selects a single spatial momentum. The time recurrence for has roots , with . Periodicity pairs propagation over steps with propagation over . Summing the images of the infinite-time propagator gives
We let float in the fit. Even an exact single pole has a vanishing symmetric slope at the midpoint. A logarithmic slope from the last two points need not give its mass. In an interacting theory, additional poles or thermal transitions can also change the time dependence.
Where the data come from. These are computer-generated measurements of the free Gaussian measure. We can sample exactly the variables used by the estimator. For the unitary temporal Fourier transform of , write for the sample mean squared amplitude across independent fields. At a nonredundant frequency its expectation is . The zero and Nyquist modes are real and have multiplicity . Each other positive frequency represents two real degrees of freedom and has . Gaussian integration gives the independent draws and their reconstruction,
This draws the exact distribution of the time-averaged measurements without generating unused spatial modes. The sample means have known covariance
The eight data sets use independent draws (NumPy default generator, seed 241118). Time indices on the same configurations remain strongly correlated. For example, at in the larger box, the correlation coefficient between and is 0.891. Here independence refers to successive field samples. For a Markov chain, keep the entire time vector together and account for autocorrelation in algorithmic time when estimating .
Fit a mass at each spacing
Select the same physical window, , on each lattice. Write so that . For a trial , define . Minimize the covariance-weighted residual for . The amplitude at fixed is
Use the covariance restricted to the fit window. A one-dimensional minimization in then gives the mass. The one-standard-error estimates below use the local curvature of the correlated two-parameter fit, with the known covariance of the mean. Each column of measurements uses its own realizations.
| at | at | |
|---|---|---|
At , , the fit gives for five degrees of freedom. Raising the lower time cut to gives . This is compatible with the first result but less precise. Treating the same time points as independent instead gives with a nominal error of . That error uses a diagonal covariance contradicted by the actual data-generating law.
Extrapolate and check the spatial volume
The exact dispersion relation predicts a specific cutoff dependence:
This explains why the coarse values sit below two. Fit the measured ratios in each box to , letting the intercept and slope vary. The input errors at different spacings are independent here. Using the three finest spacings in the larger box gives with for one degree of freedom. Multiplying by gives the reported mass.
Each marker comes from a fit to a correlated periodic-time data vector. Bars show one statistical standard error. The solid line is the fit to the three finest spacings at , extended to zero spacing. The star is the independent continuum answer for the specified free action.
The checks change one choice at a time.
| Change in the larger box, unless indicated | Continuum mass (MeV) |
|---|---|
| Three finest spacings, linear in | |
| Include the coarsest spacing | |
| Use all four spacings and add an term | |
| Later time window on all three fine lattices | |
| Three finest spacings in the smaller box |
These changes share data except for the independent spatial boxes. Keep the variations separate from the statistical error. As a check available only because this problem is solved, fitting the three exact finite-spacing ratios with the same larger-box weights gives MeV. The residual truncation error of that extrapolation is about MeV. The measured intercept is also affected by statistical fluctuations.
The two box intercepts differ by MeV. What does that comparison test? For this spatially projected free field, is independent of at every spacing. The exact rest-energy shift is zero even at finite . The box comparison checks the projection, normalization and statistical precision. Its agreement cannot establish that an interacting hadron has negligible finite-volume corrections. There the box can change the energy itself and several physical volumes or a justified correction model are needed.
Reproduce the fits
Save the correlators and covariances as continuum-mass.json. This Python example uses NumPy and SciPy. It reads the larger-box data and fits the periodic correlator, then performs the linear continuum extrapolation. The covariance matrices describe the means already, so there is no further division by the sample count.
import json
import numpy as np
from scipy.optimize import curve_fit
with open("continuum-mass.json") as stream:
ensembles = json.load(stream)["ensembles"]
points = []
for row in ensembles:
if row["length"] != 6:
continue
x, nt = row["x"], row["nt"]
n = np.arange(len(row["mean"]))
i = n[(n*x >= 1) & (n*x <= 2.5)]
y = np.asarray(row["mean"])[i]
V = np.asarray(row["covariance"])[np.ix_(i, i)]
def model(n, A, R):
return A*(np.exp(-x*R*n) + np.exp(-x*R*(nt-n)))
pars, cov = curve_fit(model, i, y, p0=(1., 2.),
sigma=V, absolute_sigma=True)
points.append((x, pars[1], np.sqrt(cov[1, 1])))
x, R, err = np.array([p for p in points if p[0] < 0.5]).T
fit, cov = curve_fit(lambda x, r, b: r + b*x**2, x, R,
sigma=err, absolute_sigma=True)
print(200*fit[0], 200*np.sqrt(cov[0, 0]))
Summary
A periodic-time fit yields the target gap on each lattice. An exactly calibrated second field puts it in common units. The continuum result uses a sequence of lattices; fit-window changes, omitted cutoff terms and spatial volume each have a separate physical meaning. The exact Gaussian answer makes all three tests interpretable.
Exercises
What does one fine lattice establish?
Quote a mass and statistical error from the , measurement. How does the estimated cutoff correction compare to that error?
Solution
The measured mass is MeV. The leading cutoff shift in is , or MeV in the mass. Its magnitude happens to match the statistical error here. Without the other spacings the data would give no measured slope or continuum intercept; estimating the shift from the analytic expansion relies on external knowledge of this action.
Diagnose a misleading plateau check
A reader uses the adjacent logarithm at instead of the periodic fit. What mass would it infer from exact data at ? Would increasing the ensemble size fix the result?
Solution
Write . The ratio of the last two values up to the midpoint is . Here . The log estimator reports , far below the true finite-spacing ratio . Increasing the sample size converges to that biased estimator. The periodic fit uses both directions of propagation and recovers the correct noise-free result.
References
- Rainer Sommer, “Scale setting in lattice QCD,” §1, Eqs. (1.1)–(1.4), on obtaining physical predictions from dimensionless ratios and a dimensionful input. arXiv:1401.3270, p. 2
- C. Michael and A. McKerrell, “Fitting Correlated Hadron Mass Spectrum Data,” §§1–2, on the covariance of a time series of correlator measurements and its role in fitting. The covariance in this Gaussian benchmark is analytically calculable. arXiv:hep-lat/9412087, pp. 1–3
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.