Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    From a Lattice Correlator to a Continuum Mass

    How do numbers measured at integer time separations give a particle mass in MeV? Start with the spatially averaged field on a finite periodic lattice. Its correlations decay in both directions around the Euclidean time circle. Fitting this decay gives an energy in lattice units. An independently calibrated reference pole sets the units, and repeating the fit at several spacings reveals the continuum limit.

    Our free-field benchmark gives 400.5±1.8400.5\pm1.8 MeV from the three finest spacings in the larger box. The quoted error is statistical. The exact continuum answer of 400 MeV lets us test the entire procedure, including the size and sign of the lattice artifact. All eight measured correlators and their time covariances are available as a small data file.

    Preparation. The free scalar lattice action supplies the dynamics. The finite-time trace explains periodic propagation, and the correlated fit introduces the statistical method.

    Fix the theory, the ruler and the box

    Use two decoupled real scalar fields in 1+11+1 Euclidean dimensions. Each has the nearest-neighbour action on a periodic Nt×NsN_t\times N_s lattice with equal spacing aa in both directions. In natural units, T=aNtT=aN_t and L=aNsL=aN_s are lengths. Write m^=am0\widehat m=am_0 for the dimensionless coefficient of the bare mass term. For either field the dimensionless inverse propagator is

    K(q0,q1)=m^2+4sin⁡2(q0/2)+4sin⁡2(q1/2).K(q_0,q_1)=\widehat m^2+4\sin^2(q_0/2)+4\sin^2(q_1/2).

    The allowed momenta are q0=2πk/Ntq_0=2\pi k/N_t and q1=2πj/Nsq_1=2\pi j/N_s. At zero spatial momentum, continuing q0q_0 to the pole iaMi aM gives m^=2sinh⁡(aM/2)\widehat m=2\sinh(aM/2). The reference field has an exactly known pole. Assign it Mr=200M_r=200 MeV and denote its value in lattice units by x=aMrx=aM_r. This fixes a=x/Mra=x/M_r. Set the target bare parameter to twice the reference value at every spacing:

    m^r=2sinh⁡(x/2),m^=2m^r.\widehat m_r=2\sinh(x/2),\qquad \widehat m=2\widehat m_r .

    Hold the vanishing interactions, this bare ratio and the reference pole in physical units fixed. In this Gaussian theory that trajectory approaches the same continuum mass ratio at every refinement. It is the example's line of constant physics. An interacting theory generally needs measured renormalized tuning conditions. The reference scale here carries no statistical or calibration error.

    Use x=1/2,1/3,1/4,1/6x=1/2,1/3,1/4,1/6. Hold TMr=6TM_r=6 and repeat the calculation at LMr=3LM_r=3 and 66. For instance, x=1/4x=1/4 in the larger box gives Nt=Ns=24N_t=N_s=24. The continuum prediction to check is the target mass, measured in units of the reference.

    Measure the periodic correlator

    Project the target field onto zero spatial momentum by taking Φj=Ns−1/2∑yφj,y\Phi_j=N_s^{-1/2}\sum_y\varphi_{j,y} on time slice jj. Average over all source times in each configuration:

    cn=1Nt∑jΦjΦj+n,Cn=⟨cn⟩.c_n=\frac1{N_t}\sum_j\Phi_j\Phi_{j+n},\qquad C_n=\langle c_n\rangle .

    The field has zero mean by reflection symmetry. The first scalar simulation measures a local field correlator averaged over axes; summing the spatial slice here selects a single spatial momentum. The time recurrence for CnC_n has roots e±ee^{\pm e}, with e=aMe=aM. Periodicity pairs propagation over nn steps with propagation over Nt−nN_t-n. Summing the images of the infinite-time propagator gives

    Cn=A[e−en+e−e(Nt−n)],A=12sinh⁡e (1−e−eNt).C_n=A\big[e^{-en}+e^{-e(N_t-n)}\big],\qquad A=\frac{1}{2\sinh e\,(1-e^{-eN_t})}.

    We let AA float in the fit. Even an exact single pole has a vanishing symmetric slope at the midpoint. A logarithmic slope from the last two points need not give its mass. In an interacting theory, additional poles or thermal transitions can also change the time dependence.

    Where the data come from. These are computer-generated measurements of the free Gaussian measure. We can sample exactly the variables used by the estimator. For the unitary temporal Fourier transform of Φ\Phi, write PkP_k for the sample mean squared amplitude across N=220N=2^{20} independent fields. At a nonredundant frequency qk=2πk/Ntq_k=2\pi k/N_t its expectation is gk=1/K(qk,0)g_k=1/K(q_k,0). The zero and Nyquist modes are real and have multiplicity dk=1d_k=1. Each other positive frequency represents two real degrees of freedom and has dk=2d_k=2. Gaussian integration gives the independent draws and their reconstruction,

    Pk=gk χdkN2dkN,Dnk=dkNtcos⁡(nqk),C‾n=∑kDnkPk.\begin{aligned} P_k&=g_k\,\frac{\chi^2_{d_kN}}{d_kN},\\ D_{nk}&=\frac{d_k}{N_t}\cos(nq_k),& \overline C_n&=\sum_k D_{nk}P_k . \end{aligned}

    This draws the exact distribution of the time-averaged measurements without generating unused spatial modes. The sample means have known covariance

    Vnm=∑kDnkDmk2gk2dkN.V_{nm}=\sum_k D_{nk}D_{mk}\frac{2g_k^2}{d_k N}.

    The eight data sets use independent draws (NumPy default generator, seed 241118). Time indices nn on the same configurations remain strongly correlated. For example, at x=1/4x=1/4 in the larger box, the correlation coefficient between n=4n=4 and 55 is 0.891. Here independence refers to successive field samples. For a Markov chain, keep the entire time vector together and account for autocorrelation in algorithmic time when estimating VV.

    Fit a mass at each spacing

    Select the same physical window, 1≤nx≤2.51\leq nx\leq2.5, on each lattice. Write R=M/MrR=M/M_r so that e=xRe=xR. For a trial RR, define fn=e−xRn+e−xR(Nt−n)f_n=e^{-xRn}+e^{-xR(N_t-n)}. Minimize the covariance-weighted residual for C‾−Af\overline C-Af. The amplitude at fixed RR is

    A(R)=fTV−1C‾fTV−1f.A(R)=\frac{f^{\mathsf T}V^{-1}\overline C}{f^{\mathsf T}V^{-1}f}.

    Use the covariance restricted to the fit window. A one-dimensional minimization in RR then gives the mass. The one-standard-error estimates below use the local curvature of the correlated two-parameter fit, with the known covariance of the mean. Each column of measurements uses its own realizations.

    aMraM_rM/MrM/M_r at LMr=3LM_r=3M/MrM/M_r at LMr=6LM_r=6
    1/21/21.9507±0.00961.9507\pm0.00961.9402±0.00951.9402\pm0.0095
    1/31/31.9706±0.00811.9706\pm0.00811.9764±0.00821.9764\pm0.0082
    1/41/41.9840±0.00751.9840\pm0.00751.9825±0.00751.9825\pm0.0075
    1/61/61.9912±0.00691.9912\pm0.00691.9975±0.00701.9975\pm0.0070

    At x=1/4x=1/4, LMr=6LM_r=6, the fit gives χ2=2.09\chi^2=2.09 for five degrees of freedom. Raising the lower time cut to nx≥1.5nx\geq1.5 gives R=1.9798±0.0199R=1.9798\pm0.0199. This is compatible with the first result but less precise. Treating the same time points as independent instead gives 1.98571.9857 with a nominal error of 0.00720.0072. That error uses a diagonal covariance contradicted by the actual data-generating law.

    Extrapolate and check the spatial volume

    The exact dispersion relation predicts a specific cutoff dependence:

    R(x)=2xarsinh⁡[2sinh⁡(x/2)]=2−x24+O(x4).R(x)=\frac{2}{x}\operatorname{arsinh}\big[2\sinh(x/2)\big] =2-\frac{x^2}{4}+O(x^4).

    This explains why the coarse values sit below two. Fit the measured ratios in each box to R0+bx2R_0+b x^2, letting the intercept and slope vary. The input errors at different spacings are independent here. Using the three finest spacings in the larger box gives R0=2.00247±0.00917R_0=2.00247\pm0.00917 with χ2=0.46\chi^2=0.46 for one degree of freedom. Multiplying by MrM_r gives the reported mass.

    Fitted scalar masses in two boxes rise as the squared spacing decreases. The larger-box fit extrapolates to the 400 MeV continuum benchmark.

    Each marker comes from a fit to a correlated periodic-time data vector. Bars show one statistical standard error. The solid line is the fit to the three finest spacings at LMr=6LM_r=6, extended to zero spacing. The star is the independent continuum answer for the specified free action.

    The checks change one choice at a time.

    Change in the larger box, unless indicatedContinuum mass (MeV)
    Three finest spacings, linear in x2x^2400.49±1.83400.49\pm1.83
    Include the coarsest spacing400.44±1.25400.44\pm1.25
    Use all four spacings and add an x4x^4 term400.71±2.30400.71\pm2.30
    Later time window on all three fine lattices400.81±5.31400.81\pm5.31
    Three finest spacings in the smaller box399.69±1.82399.69\pm1.82

    These changes share data except for the independent spatial boxes. Keep the variations separate from the statistical error. As a check available only because this problem is solved, fitting the three exact finite-spacing ratios with the same larger-box weights gives 399.93399.93 MeV. The residual truncation error of that extrapolation is about 0.070.07 MeV. The measured intercept is also affected by statistical fluctuations.

    The two box intercepts differ by 0.80±2.590.80\pm2.59 MeV. What does that comparison test? For this spatially projected free field, K(q0,0)K(q_0,0) is independent of NsN_s at every spacing. The exact rest-energy shift is zero even at finite LL. The box comparison checks the projection, normalization and statistical precision. Its agreement cannot establish that an interacting hadron has negligible finite-volume corrections. There the box can change the energy itself and several physical volumes or a justified correction model are needed.

    Reproduce the fits

    Save the correlators and covariances as continuum-mass.json. This Python example uses NumPy and SciPy. It reads the larger-box data and fits the periodic correlator, then performs the linear continuum extrapolation. The covariance matrices describe the means already, so there is no further division by the sample count.

    import json
    import numpy as np
    from scipy.optimize import curve_fit
    
    with open("continuum-mass.json") as stream:
        ensembles = json.load(stream)["ensembles"]
    
    points = []
    for row in ensembles:
        if row["length"] != 6:
            continue
        x, nt = row["x"], row["nt"]
        n = np.arange(len(row["mean"]))
        i = n[(n*x >= 1) & (n*x <= 2.5)]
        y = np.asarray(row["mean"])[i]
        V = np.asarray(row["covariance"])[np.ix_(i, i)]
    
        def model(n, A, R):
            return A*(np.exp(-x*R*n) + np.exp(-x*R*(nt-n)))
    
        pars, cov = curve_fit(model, i, y, p0=(1., 2.),
                              sigma=V, absolute_sigma=True)
        points.append((x, pars[1], np.sqrt(cov[1, 1])))
    
    x, R, err = np.array([p for p in points if p[0] < 0.5]).T
    fit, cov = curve_fit(lambda x, r, b: r + b*x**2, x, R,
                         sigma=err, absolute_sigma=True)
    print(200*fit[0], 200*np.sqrt(cov[0, 0]))
    

    Summary

    A periodic-time fit yields the target gap on each lattice. An exactly calibrated second field puts it in common units. The continuum result uses a sequence of lattices; fit-window changes, omitted cutoff terms and spatial volume each have a separate physical meaning. The exact Gaussian answer makes all three tests interpretable.

    Exercises

    What does one fine lattice establish?

    Quote a mass and statistical error from the x=1/6x=1/6, LMr=6LM_r=6 measurement. How does the estimated cutoff correction compare to that error?

    Solution

    The measured mass is 200(1.99753±0.00696)=(399.51±1.39)200(1.99753\pm0.00696)=(399.51\pm1.39) MeV. The leading cutoff shift in RR is −x2/4=−1/144-x^2/4=-1/144, or −1.39-1.39 MeV in the mass. Its magnitude happens to match the statistical error here. Without the other spacings the data would give no measured slope or continuum intercept; estimating the shift from the analytic expansion relies on external knowledge of this action.

    Diagnose a misleading plateau check

    A reader uses the adjacent logarithm at n=Nt/2−1n=N_t/2-1 instead of the periodic fit. What mass would it infer from exact data at x=1/4x=1/4? Would increasing the ensemble size fix the result?

    Solution

    Write Cn=2A e−eNt/2cosh⁡[e(Nt/2−n)]C_n=2A\,e^{-eN_t/2}\cosh[e(N_t/2-n)]. The ratio of the last two values up to the midpoint is cosh⁡e\cosh e. Here e=2arsinh⁡[2sinh⁡(1/8)]≃0.4962e=2\operatorname{arsinh}[2\sinh(1/8)]\simeq0.4962. The log estimator reports Rlog⁡=x−1log⁡cosh⁡e≃0.473R_{\log}=x^{-1}\log\cosh e\simeq0.473, far below the true finite-spacing ratio 1.98481.9848. Increasing the sample size converges to that biased estimator. The periodic fit uses both directions of propagation and recovers the correct noise-free result.

    References

    • Rainer Sommer, “Scale setting in lattice QCD,” §1, Eqs. (1.1)–(1.4), on obtaining physical predictions from dimensionless ratios and a dimensionful input. arXiv:1401.3270, p. 2
    • C. Michael and A. McKerrell, “Fitting Correlated Hadron Mass Spectrum Data,” §§1–2, on the covariance of a time series of correlator measurements and its role in fitting. The covariance in this Gaussian benchmark is analytically calculable. arXiv:hep-lat/9412087, pp. 1–3

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.