A smooth continuum gauge field can have integer topological charge, yet a lattice field-strength calculation may return . Is the field in the wrong sector, or is the estimator inaccurate? To answer, we must distinguish a continuum invariant, a finite-spacing definition and the effect of smoothing. We will follow one explicit flux configuration across three spacings and then identify what additional information is needed for a quantum susceptibility.
Preparation: Oriented links and plaquettes and gradient flow. The fermionic comparison uses the meaning of a Dirac zero mode and chirality; its lattice relation is stated explicitly below.
Continuum charge and its boundary conditions
First consider four-dimensional Euclidean theory, . Set , use Hermitian generators with , and retain the site's . Define
With the usual untwisted bundle and boundary conditions, a smooth finite-action field on compactified , or a smooth connection on a closed four-manifold with the appropriate bundle, has integer . Boundary conditions matter: an arbitrary open subregion does not have an integer charge, and twisted boundary data require their own quantization statement.
Why can a local density give a global integer? In differential-form notation, introduce the anti-Hermitian connection , curvature , and
Locally is the exterior derivative of a Chern–Simons three-form. The potential need not be one smooth, globally trivial gauge choice: transition functions between patches, or the pure gauge at spatial infinity, carry an integer winding. This is why a nonzero charge cannot be excluded by treating the density as a globally harmless total derivative.
There is also a direct test of stability. For a smooth variation of the connection, the Bianchi identity gives
It vanishes on a closed manifold, or with sufficiently restrictive falloff and boundary data. Smooth gradient flow is such a variation, so continuum is independent of flow time under these assumptions. The local flow identity and the role of total derivatives are developed in Cè et al., §2, Eqs.(2.4)–(2.9); their Hermitian connection absorbs the coupling, .
A field-strength estimator at finite spacing
For the site's forward links, a positive plaquette based at is
Products act on a vector from right to left. To reduce the error from locating the curvature at a corner, sum the four positively oriented elementary loops in the plane that are based at . Call this sum . The clover field strength is
For a smooth field, the four loops each contribute ; the subtraction doubles that term. Thus with the displayed sign. Translating a backward-link formula without changing its orientation would spoil this check.
Replace the curvatures in by these clover estimates and integrate by a lattice sum:
This gauge-invariant real number is generally not an integer at finite . Evaluating it on links flowed to a positive physical time suppresses rough short-distance fluctuations and often reveals values near integers. It does not make this particular polynomial estimator exactly quantized. Rounding it to the nearest integer conceals discretization errors and becomes ambiguous for rough fields.
A small lattice dislocation is a localized rough configuration at the cutoff scale that can resemble a topological object to one estimator. Under lattice flow it can disappear or pass between apparent sectors. Even an initially smooth continuum-like lump can shrink to the cutoff under a discretized action if evolved too far. The continuum invariance proof required a smooth connection and controlled boundaries throughout; it does not forbid these finite-spacing events.
The space of all unconstrained lattice links is connected. To separate exact sectors, a geometric construction or an index must exclude, or become singular at, particular rough configurations. Conditions that keep plaquettes sufficiently close to the identity can supply that separation. The applicable bound and the definition are part of the statement; there is no universal numerical smoothness threshold shared by all groups and actions. Lüscher, §§4.2–4.3 explains this separation for flowed fields.
A periodic flux configuration that we can calculate
Use a separate two-dimensional compact-U(1) torus of side . Its charge is a first Chern number,
It is not the four-dimensional invariant. The example below tests discretization and smoothing with an exactly known charge.
Let and for integer , with so the desired flux lies inside the principal plaquette branch. A constant-flux link configuration is
The last row supplies the transition across the periodic seam. Substitution into the positive plaquette gives everywhere: the corner angle differs by , which is invisible to the compact link product. Omitting the seam would introduce a compensating sheet of flux and change the construction.
For principal plaquette angles , compare
On a periodic U(1) lattice, the product of all plaquettes is one because links cancel in pairs. Therefore the sum of principal angles is times an integer. Away from a plaquette's branch cut, cannot change continuously. This two-dimensional geometric definition is discussed in Bonati and Rossi, §III, Eqs.(16)–(20).
The sine definition instead estimates the curvature by . For the constant field,
Uniform flux is stationary under the link flow: every plaquette has the same sine, and each link meets two plaquettes with opposite orientation. Flow therefore cannot remove even this simple estimator's residual bias. Refining the grid can.
Following a smooth deformation at matched physical times
To obtain a nontrivial flow, take and multiply each link by
Here has dimensions of inverse length and perturbs the coupling-absorbed potential . Its extra plaquette angle is a difference of neighboring sines, so its sum vanishes. The continuum curvature represented by these links is
The charge remains one, although the local field is not constant and can change sign. In continuum Abelian flow the deformation decays exactly:
We evolve the actual compact links with , using periodic incidence matrices and . This calculation shares the geometry and flow algorithm with the previous article but uses no random ensemble. The initial continuum field, , and each physical observation time are the same for .
| Largest initial | |||
|---|---|---|---|
| 16 | 0.072379 | 0.999305061 | 0.999774422 |
| 32 | 0.018329 | 0.999956197 | 0.999985949 |
| 64 | 0.004597 | 0.999997257 | 0.999999122 |
At every recorded time, is one to within . The action decreases at every integration step, and all recorded plaquette angles remain far from the branch cut. The final sine-charge deficits fall by factors 16.05 and 16.01 when halves. This is the expected behavior of this particular smooth two-dimensional sine estimator; it is not the generic error order of a four-dimensional clover charge.
Actual periodic U(1) link flow for a smooth flux with , at three spacings and the same physical times. The geometric charge remains one. Solid curves show the noninteger sine estimator's deficit; dashed lines show its constant-flux value at the corresponding spacing. There are no statistical error bars because these are deterministic configurations, not an ensemble. The vertical axis is logarithmic.
The selected integration uses . Halving the maximum step from to changes any saved plaquette angle by less than , well below the discretization differences. Comparing the final lattice curvature at plaquette midpoints with the displayed continuum solution gives maximum errors , and in units of . Their approximately fourfold decrease is a separate second-order continuum check. A constant-flux run stays stationary, and a gauge transformation leaves the geometric charge unchanged.
A useful common interval here is . Its two-dimensional root-mean-square radius is to . The coarsest grid has only , so separation from the cutoff is modest at its lower end; the finer grids improve that separation at the same physical time. We inspect charge and curvature across spacings, not merely a flat-looking segment on one grid. Because the starting field is already smooth, there is no initial dislocation to remove and no topological transition to demonstrate.
What a fermionic definition adds
In four dimensions, an exact lattice chiral relation gives another route to an integer charge. Let be a lattice Dirac operator with -Hermiticity and the Ginsparg–Wilson relation
The normalization of the coefficient is part of the definition: overlap conventions often use a rescaled coefficient in place of . For this displayed normalization, define the one-flavor index
The trace includes sites, spin and color; count exact zero modes of chirality . Nonzero spectral contributions cancel or have zero weight, leaving an integer. This index identity follows from the exact lattice chiral symmetry; see Lüscher, §4, Eqs.(4.2)–(4.6).
To fix the sign relative to the above, choose Hermitian Euclidean gamma matrices and . Then , and the continuum index for agrees with the displayed . Reversing the chirality orientation reverses the zero-mode counting convention. An unqualified formula without this convention can carry the opposite sign in another source.
A generic Wilson Dirac operator does not satisfy this relation and cannot be inserted into this trace as an exact index formula. For overlap operators, locality and the definition of the sign function also need control; a rough field can drive the kernel through a zero eigenvalue. The resulting finite-spacing index changes do not contradict continuum topological stability.
The field-strength, flowed and fermionic constructions thus have different finite-spacing properties. Their continuum agreement is a universality statement with a specified limit, not equality on every rough lattice configuration. For Yang–Mills theory, the relation of positive-flow-time charge cumulants to a Ginsparg–Wilson definition, including the treatment of contact terms, is established in Cè et al., §§3.1–3.3, especially Eqs.(3.29)–(3.33). Those cumulants are more information than the charge of our one classical field.
When a susceptibility is meaningful
For a sampled ensemble in a physical four-volume , the connected susceptibility is
At zero theta angle in a CP-symmetric ensemble, in the ideal measure; retaining the subtraction is useful for finite samples and more general situations. With a properly defined density, also equals an integrated connected correlation function. The coincidence region requires control: an unflowed naive lattice product cannot simply be assumed to have the correct continuum contact terms.
One practical prescription measures flowed charge at fixed positive physical , takes the continuum limit with fixed physical volume and controlled boundaries, and then checks the infinite-volume limit. Smooth continuum charge is flow-time independent under the boundary assumptions already stated, so residual dependence can diagnose cutoff or boundary effects. An operator-matching prescription is needed if one instead sends to zero while the cutoff remains finite.
Sampling is equally consequential. If a Markov chain remains frozen in one sector, a nearly constant charge and tiny estimated variance do not establish a small physical susceptibility. Flow smooths each configuration; it does not repair missing transitions or make correlated measurements independent. One must assess autocorrelations, sector coverage and finite-volume effects. Open boundaries allow charge flux and require a corresponding bulk observable and boundary analysis; the closed-manifold invariance argument cannot be applied unchanged.
Our configuration is deliberately fixed. Treating it as an ensemble would give zero connected variance by construction and no estimate of . Its useful result is narrower: charge quantization, estimator bias and continuum curvature can be tested separately on the same smooth field.
Summary
Topological charge needs both a definition and boundary conditions. A flowed field-strength estimate can approach an integer without being exactly integer at finite spacing; a geometric or fermionic definition supplies different finite-cutoff information. The smooth torus example shows these differences explicitly. A susceptibility additionally requires a correctly sampled quantum distribution and controlled continuum, volume and contact-term limits.
Exercises
Uniform flux does not cure a sine estimator
For integer charge on an torus, assume . Derive the leading error of and explain why further link flow cannot remove it. What occurs at the boundary of the assumed angle range?
Solution
All principal plaquettes equal . Expanding gives
On a torus , so the link force vanishes. The bias is stationary; one must change the estimator or the spacing. At , the geometric principal-branch definition reaches its discontinuity. Passing through it can change the integer obtained from the sum of principal angles, so the smooth-sector argument no longer applies across that crossing.
Where the fourth power comes from
Let be a fixed smooth two-dimensional curvature and suppose each plaquette angle is its integrated flux, , with no branch crossing. Derive the leading difference between and as . Why can the local curvature still have only second-order accuracy?
Solution
For a midpoint , smoothness gives . Therefore
There are plaquettes, each cubic term is , and their sum is . This argument assumes a fixed smooth field and a controlled integrated-flux discretization; it does not assign an error order to rough quantum fields or to the four-dimensional clover operator. Dividing by gives , so local curvature generally has second-order error even though the difference between these two total-charge estimators starts at fourth order. For the deformed positive-charge example, the integral of is positive, explaining the plotted deficit's sign.
References
- C. Bonati and P. Rossi, “The topological susceptibility of two-dimensional U(N) gauge theories,” arXiv:1901.09830, §III, Eqs.(16)–(20).
- M. Cè, C. Consonni, G. P. Engel and L. Giusti, “Non-Gaussianities in the topological charge distribution of the SU(3) Yang–Mills theory,” Phys. Rev. D 92 (2015) 074502, arXiv:1506.06052, §§2–3 and Appendix A.
- M. Lüscher, “Exact chiral symmetry on the lattice and the Ginsparg–Wilson relation,” Phys. Lett. B 428 (1998) 342–345, arXiv:hep-lat/9802011, §§3–4.
- M. Lüscher, “Properties and uses of the Wilson flow in lattice QCD,” JHEP 08 (2010) 071, arXiv:1006.4518, revised version, §§4.2–4.4.