Gradient Flow
A plaquette measured on a quantum gauge field contains fluctuations all the way down to the lattice spacing. Can we resolve the field over a chosen physical distance without fixing its gauge? Gradient flow supplies a deterministic smoothing equation. We will derive its resolution scale, evolve the chapter's compact-U(1) configurations, and distinguish smoothing errors from lattice and statistical errors.
Preparation: Links and plaquettes, the Wilson action, and Gaussian Fourier integrals.
A gauge-covariant smoothing equation
Work in Euclidean space. Let be a Hermitian gauge potential at flow time , with initial value . Flow time has dimensions of length squared; it is an auxiliary variable, not a real or Euclidean time coordinate of the original field theory. In the site's convention,
The Yang–Mills gradient flow is
It moves in the direction that decreases the Euclidean gauge action. Gauge transformations independent of take solutions to solutions. The flow therefore gives a new gauge field on each configuration and permits gauge-invariant measurements at positive .
Lüscher's defining equations (1.1)–(1.4) use an anti-Hermitian connection. The explicit dictionary is , and . Then . The site's forward transporter is ; this translation matters when reading a source that assigns a link to the reverse direction.
No new field configurations are sampled by this equation. Starting from one configuration and flowing it to ten times gives ten correlated measurements of that same configuration.
The heat kernel and the smoothing radius
Linearize around the zero field, keeping only terms first order in . The flow becomes
The transverse components diffuse. A longitudinal component is a pure gauge direction and does not relax in this form of the equation. To expose the full heat kernel, add to the flow. This modifies the representative by a time-dependent gauge transformation, leaving gauge-invariant observables unchanged. At linear order the modified equation is simply ; the relation between the two flows is developed in Lüscher, §2.1, Eqs.(2.2)–(2.4).
Fourier transforming in Euclidean dimensions gives
Transform back to obtain
The kernel integrates to one. Each coordinate has variance , so its radial mean square is
Thus the familiar is the four-dimensional root-mean-square radius. In our two-dimensional example that radius is . It is not a sharp cutoff: the kernel has tails, and a Fourier mode is attenuated continuously by . The nonlinear non-Abelian flow retains this useful short-distance interpretation, although its solution is not a componentwise Gaussian convolution.
For an elementary lattice check, take a periodic grid and a weak transverse link angle , . The linearized lattice flow predicts
The numerical check uses , , and . Fourth-order Runge–Kutta steps , and give relative errors , and against this exponential. The approximately sixteenfold improvement per halving identifies the integration error; the amplitude is small enough that nonlinear corrections do not dominate this test.
Flowing links on the shared ensemble
Use the chapter's open two-dimensional compact-U(1) lattice, with plaquettes, equal spacing , and
Here is the dimensionful two-dimensional gauge coupling, is a forward link, and denotes a plaquette angle, not momentum. Introduce the oriented incidence matrix : each row adds the four link angles around a positive plaquette, so . This is a matrix on the finite grid, distinct from the continuum potential .
After absorbing the action's overall coupling into the conventional flow normalization, the link equation in dimensionless time is
It evolves links collectively. Flowing each plaquette independently by would give a different process: neighboring plaquettes share links. Multiplying the link equation by yields the actual plaquette evolution .
Two exact identities make useful checks. First,
Second, let map site phases to link differences. A gauge transformation is , with the final endpoint minus the initial endpoint. Since , the force is unchanged. Corresponding trajectories remain related by that gauge transformation. Compact links can be reconstructed from unwrapped angles throughout the integration; resetting an individual angle by changes neither the force nor the observables.
On an open lattice, a maximal-tree gauge makes the initial plaquettes independent with density . We use the first 256 configurations of the same fixed sample stream used for the static-potential calculation, rather than resampling a separate ensemble. All links, including boundary links, evolve. The measured observable is the dimensionless action density
For a smooth Abelian field , this corresponds to averaged over the grid. The plot retains lattice units. It does not transplant a four-dimensional normalization into two dimensions.
| Mean | Standard error | |
|---|---|---|
| 0 | 0.136289 | 0.000995 |
| 0.25 | 0.034875 | 0.000414 |
| 0.5 | 0.014452 | 0.000260 |
| 1 | 0.005564 | 0.000147 |
| 2 | 0.002134 | 0.000080 |
| 4 | 0.000762 | 0.000041 |
At , the exact mean is , within the sampling uncertainty. The errors in the table come from variation between independent configurations. Values at different flow times remain correlated; the companion retains their covariance.
Actual link flow on the open compact-U(1) ensemble at . Points show the mean and one standard error; the diamond marks the exact initial mean. The vertical axis is logarithmic. Boundary effects are part of this finite-grid observable. Both the figure and its numerical data come from this calculation.
The selected curve uses Runge–Kutta step . Repeating it with and gives maximum differences, over every configuration and saved time, of and in . The latter is much smaller than the statistical errors. Every integration step decreases the action. A directional finite-difference derivative checks the force, and evolving gauge-transformed initial links changes plaquette phases by less than . These checks test this finite calculation; no continuum or infinite-volume limit was taken.
Choosing a physical flow window
Three scales must be separated for a continuum flowed observable:
in four dimensions, together with control of any other physical length relevant to the observable. The first inequality suppresses cutoff effects that can contain powers of . The second limits finite-volume and boundary contamination. If the aim is to approximate an unsmeared local quantity, must also be small relative to its physical variation scale, and the small-flow-time matching must be performed. These are different purposes for choosing .
In four-dimensional Yang–Mills theory a common flowed energy density is
The repeated indices are summed; . At positive physical flow time, gauge-invariant local composites of the flowed gauge field are ultraviolet finite after ordinary renormalization of the underlying theory. The all-orders perturbative proof and the qualifications for the expansion are given by Lüscher and Weisz, §§7–8, especially §8.2. Small can still produce singular coefficients and mixing with the identity; smoothing does not remove the need to match an unflowed composite operator.
An equation such as , for a specified constant and an appropriate crossing, defines a reference scale. Its scheme, discretization, statistical uncertainty and continuum extrapolation are part of scale setting. Holding fixed while refining drives the physical smoothing length to zero. To compare the same finite-flow-time observable across spacings, hold a physical combination such as fixed instead.
Finally, gradient flow alone is not an exact Wilsonian renormalization-group transformation. On a finite lattice the smooth flow is an invertible change of link variables at every finite time; a change of variables in the path integral also requires its Jacobian. It has not integrated out a set of degrees of freedom or supplied a coarse-grained effective action. This distinction is particularly clear in Lüscher, §4.1. The next article uses flow to compare topological-charge definitions, with a separate periodic configuration and a matched physical window.
Summary
Gradient flow suppresses short-distance gauge-field fluctuations through a deterministic, gauge-covariant evolution. The heat kernel fixes its characteristic radius, while the link gradient supplies action and gauge checks. A useful calculation controls integration steps, correlated statistics, physical flow time, lattice spacing and boundaries separately.
Exercises
Which limit keeps the smoothing scale?
A four-dimensional calculation uses , and . Refine to at fixed . Find the new required to preserve the physical flow time and compute before and after refinement. What happens if is left equal to two?
Solution
The dimensionless physical time is . Halving therefore requires . Both grids then have . If , the new physical time is , a quarter of the old one, and the smoothing radius is . That calculation compares different observables. Keeping fixed does not by itself fix the flow prescription.
Why independent plaquette cooling fails
Consider two open plaquettes sharing one link. Choose their orientations so the shared link has opposite signs in the two plaquettes. Find and their flow equations. For small equal angles , compare their initial decay rate with two isolated plaquettes.
Solution
Each plaquette contains four links, and their one shared link contributes to the off-diagonal inner product. Hence
For small equal angles, . An isolated plaquette has . Shared links change the relaxation modes. The symmetric and antisymmetric combinations of the pair decay at rates 3 and 5; neither is reproduced by assigning the same independent one-plaquette equation to each face.
References
- M. Lüscher, “Properties and uses of the Wilson flow in lattice QCD,” JHEP 08 (2010) 071, arXiv:1006.4518, revised version, §§1–2 and §4.1.
- M. Lüscher and P. Weisz, “Perturbative analysis of the gradient flow in non-abelian gauge theories,” JHEP 02 (2011) 051, arXiv:1101.0963, §§7–8.
Reproducible calculation: examples/lattice-hamiltonian/lattice-gauge-theory/flow.py, flow-results.json and plot_flow.py, using the shared u1.py geometry and ensemble.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.