Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Matching to Nonperturbative Matrix Elements

    A perturbative Wilson coefficient and a lattice matrix element cannot be multiplied merely because they refer to an operator with the same name. The operator normalization, subtraction scheme, scale and mixing prescription must also agree. Their separate scheme dependence cancels only after the coefficient is transformed in the opposite way.

    We will combine a short-distance coefficient with a supplied synthetic four-fermion matrix element, evolve it through two steps, convert schemes and propagate correlated uncertainties. The numbers below are teaching inputs, not a lattice calculation, an experimental fit or a prediction for neutral-meson mixing.

    Preparation: Renormalized operator insertions, operator mixing and Wilson-coefficient evolution.

    Specify the matrix element

    Consider the color-singlet operator

    Q=(sˉαγμPLdα)(sˉβγμPLdβ),PL=1−γ52.Q=(\bar s_\alpha\gamma_\mu P_Ld_\alpha)(\bar s_\beta\gamma^\mu P_Ld_\beta),\qquad P_L=\frac{1-\gamma_5}{2}.

    The effective Hamiltonian includes CQ+C∗Q†C Q+C^*Q^\dagger. We assume a chirally symmetric regularization and a physical sector in which this operator renormalizes multiplicatively after any required evanescent-operator prescription has been fixed. A regulator with broken chiral symmetry can require additional operator subtractions; the one-dimensional example is not a rule that all four-fermion mixing disappears.

    Let MX(μ)=⟨Pˉ∣QX(μ)∣P⟩\mathcal M_X(\mu)=\langle\bar P|Q_X(\mu)|P\rangle, with relativistically normalized neutral pseudoscalar states. This matrix element has mass dimension four, whereas CXC_X has dimension minus two. Their product has dimension two. A physical mass splitting would require the additional normalization and other contributions appropriate to its observable; we do not identify this product alone with a measured splitting.

    An off-shell scheme XX can be defined in Landau gauge using an amputated four-quark vertex ΓQ\Gamma_Q and a projector P\mathscr P normalized by PΓQtree=1\mathscr P\Gamma_Q^{\rm tree}=1:

    Zq−2ZQX PΓQ∣subtraction point=1,QX=ZQXQbare.Z_q^{-2}Z_Q^X\,\mathscr P\Gamma_Q\big|_{\rm subtraction\ point}=1,\qquad Q_X=Z_Q^XQ_{\rm bare}.

    For definiteness, take a nonexceptional Euclidean tetrahedral configuration: ∑ipi=0\sum_i p_i=0, pi2=μ2p_i^2=\mu^2, and pi⋅pj=−μ2/3p_i\cdot p_j=-\mu^2/3 for i≠ji\ne j. Every two-leg partial sum then has squared length 4μ2/34\mu^2/3. Choose P\mathscr P as the normalized Euclidean tensor inner product with the tree Dirac/color tensor, and determine the quark normalization by Zq=−itr⁡[p̸Sbare−1(p)]/(4Ncμ2)Z_q=-i\operatorname{tr}[\not p S_{\rm bare}^{-1}(p)]/(4N_c\mu^2) at p2=μ2p^2=\mu^2, with Hermitian Euclidean gamma matrices and the trace over spin and color (Nc=3N_c=3). These conditions illustrate the information a scheme must supply. They do not compute a real QCD conversion coefficient for this scheme.

    This lattice convention QX=ZQXQbareQ_X=Z_Q^XQ_{\rm bare} is the inverse of the continuum convention Qbare=ZQRQ_{\rm bare}=ZQ_R used in the operator-mixing chapter. Stating the direction avoids an accidental inverse or transpose. Martinelli et al., §3.2 exhibit the four-fermion renormalization condition and the role of additional mixing. Their unhalved (1−γ5)(1-\gamma_5) currents differ from our PLP_L currents by an overall factor four in QQ.

    For an actual operator construction, extract the weak matrix element from a ratio of lattice correlators and keep its bare normalization explicit. The conversion below starts from such an input. The momentum-subtraction projectors specify what the intermediate renormalization factor measures.

    Step scaling preserves the operator definition

    At finite lattice spacing alata_{\rm lat}, form the ratio of renormalization constants and take a controlled continuum limit:

    σX(μ2,μ1)=lim⁡alat→0ZQX(μ2,alat)ZQX(μ1,alat),MX(μ2)=σX(μ2,μ1)MX(μ1).\sigma_X(\mu_2,\mu_1)=\lim_{a_{\rm lat}\to0}\frac{Z_Q^X(\mu_2,a_{\rm lat})}{Z_Q^X(\mu_1,a_{\rm lat})},\qquad \mathcal M_X(\mu_2)=\sigma_X(\mu_2,\mu_1)\mathcal M_X(\mu_1).

    The simulation would also need volume, quark-mass and discretization control; a ratio alone does not prove these limits. Here the continuum step factors are supplied synthetic inputs. Composition gives σX(μ3,μ1)=σX(μ3,μ2)σX(μ2,μ1)\sigma_X(\mu_3,\mu_1)=\sigma_X(\mu_3,\mu_2)\sigma_X(\mu_2,\mu_1), while the coefficient evolves oppositely so that CXMXC_X\mathcal M_X stays invariant.

    At a fixed scale, let QY=RYXQXQ_Y=R_{YX}Q_X. Then

    MY=RYXMX,CX=RYXCY,CYMY=CXMX.\mathcal M_Y=R_{YX}\mathcal M_X,\qquad C_X=R_{YX}C_Y,\qquad C_Y\mathcal M_Y=C_X\mathcal M_X.

    For a column of operators, the corresponding coefficient relation is CX=RYXTCYC_X=R_{YX}^{T}C_Y when the Hamiltonian is CTOC^TO. Complex coefficients use the same algebraic transpose in this contraction; Hermitian conjugation belongs to the separately included conjugate Hamiltonian.

    Carry out the synthetic conversion

    Use the following central values:

    InputValueRelative standard uncertainty
    MX(2 GeV)\mathcal M_X(2\,\mathrm{GeV})0.012 GeV40.012\,\mathrm{GeV}^44%4\%
    σX(4,2)\sigma_X(4,2)0.960.961.5%1.5\%
    σX(8,4)\sigma_X(8,4)0.970.971.2%1.2\%
    RYX(8 GeV)R_{YX}(8\,\mathrm{GeV})1.041.041%1\%

    The scales in the step factors are in GeV. Define the finite scheme coordinate in this example by RYX(8)=1+2aR_{YX}(8)=1+2a at a=0.02a=0.02. This number is specified for the synthetic example; it is not presented as a calculated RI-to-modified-MS coefficient. Supply the short-distance coefficient CY(8)=1.06×10−10 GeV−2C_Y(8)=1.06\times10^{-10}\,\mathrm{GeV}^{-2}. Its own uncertainty is set aside to isolate the matrix-element and conversion problem; a real prediction must include it.

    The two steps give σX(8,2)=0.9312\sigma_X(8,2)=0.9312 and

    MY(8)=1.04(0.97)(0.96)(0.012)=0.011621376 GeV4.\mathcal M_Y(8)=1.04(0.97)(0.96)(0.012)=0.011621376\,\mathrm{GeV}^4.

    Therefore the common product is

    A=CY(8)MY(8)=1.231865856×10−12 GeV2.\mathcal A=C_Y(8)\mathcal M_Y(8)=1.231865856\times10^{-12}\,\mathrm{GeV}^2.

    The same result follows by evolving the coefficient to the original scheme and scale:

    CX(2)=RYX(8)σX(8,4)σX(4,2)CY(8)=1.02655488×10−10 GeV−2.C_X(2)=R_{YX}(8)\sigma_X(8,4)\sigma_X(4,2)C_Y(8)=1.02655488\times10^{-10}\,\mathrm{GeV}^{-2}.

    Multiplying this by 0.012 GeV40.012\,\mathrm{GeV}^4 reproduces A\mathcal A. No new fit has been performed at either scale.

    The unexpanded central products above use the stated finite coordinate transformation exactly. If instead a conversion is known only perturbatively, it must be truncated consistently. For R=1+ar+O(a2)R=1+ar+O(a^2), the inverse is 1−ar+O(a2)1-ar+O(a^2), so

    (1−ar)(1+ar)=1−a2r2.(1-ar)(1+ar)=1-a^2r^2.

    The residual is of the first omitted order, not an exact scheme dependence. With r=2r=2 and a=0.04,0.02,0.01a=0.04,0.02,0.01, the residuals are 0.0064,0.0016,0.00040.0064,0.0016,0.0004; halving aa reduces the error by four. Using an exactly inverted truncated factor instead is an algebraic convention that includes selected higher-order terms, not knowledge of the full two-loop conversion.

    Propagate correlations, not just separate error bars

    Let x=(MX,σ42,σ84,R)x=(\mathcal M_X,\sigma_{42},\sigma_{84},R) be the four supplied inputs. Their covariance is Σij=xixjdidjρij\Sigma_{ij}=x_i x_j d_i d_j\rho_{ij}, with relative uncertainties d=(0.04,0.015,0.012,0.01)d=(0.04,0.015,0.012,0.01) and the explicitly synthetic correlation matrix

    ρ=(10.5−0.20.250.510.159807620.03839746−0.20.1598076210.106547580.250.038397460.106547581).\rho=\begin{pmatrix} 1&0.5&-0.2&0.25\\ 0.5&1&0.15980762&0.03839746\\ -0.2&0.15980762&1&0.10654758\\ 0.25&0.03839746&0.10654758&1 \end{pmatrix}.

    The companion defines this positive matrix through a triangular factor before rounding the displayed entries. To first order in input fluctuations, the gradient is gi=∂A/∂xi=A/xig_i=\partial\mathcal A/\partial x_i=\mathcal A/x_i, hence

    Var⁡(A)=gTΣg=A2∑i,jdiρijdj.\operatorname{Var}(\mathcal A)=g^T\Sigma g=\mathcal A^2\sum_{i,j}d_i\rho_{ij}d_j.

    It gives a standard uncertainty 6.4853×10−14 GeV26.4853\times10^{-14}\,\mathrm{GeV}^2. Setting all off-diagonal correlations to zero instead gives 5.6033×10−14 GeV25.6033\times10^{-14}\,\mathrm{GeV}^2. Shared ensembles and renormalization fits can therefore matter as much as an individual uncertainty.

    A seeded simulation of 300,000300{,}000 correlated Gaussian input vectors gives 6.4833×10−14 GeV26.4833\times10^{-14}\,\mathrm{GeV}^2, consistent with the linear propagation at these small uncertainties. This is a check of the specified error model, not evidence that a real lattice distribution is Gaussian. Perturbative truncation, continuum extrapolation and missing matrix elements require their own justified uncertainty treatment rather than being silently absorbed into these four numbers.

    Summary

    Matching to a nonperturbative matrix element means translating both factors into one operator definition, scale and scheme. Step scaling moves the matrix element and the coefficient in opposite directions. A synthetic worked example makes the cancellation and correlated error propagation explicit while keeping supplied data distinct from a first-principles UV derivation.

    Exercises

    1. Convert a whole step instead of its endpoint

    Suppose RYX(2)=1.08R_{YX}(2)=1.08, RYX(4)=1.06R_{YX}(4)=1.06, and RYX(8)=1.04R_{YX}(8)=1.04. Determine the two step factors in scheme YY and verify composition.

    Solution

    At each endpoint QY=RQXQ_Y=RQ_X, so

    σY(μ2,μ1)=R(μ2)σX(μ2,μ1)R(μ1)−1.\sigma_Y(\mu_2,\mu_1)=R(\mu_2)\sigma_X(\mu_2,\mu_1)R(\mu_1)^{-1}.

    Thus σY(4,2)=1.06(0.96)/1.08=0.94222222\sigma_Y(4,2)=1.06(0.96)/1.08=0.94222222 and σY(8,4)=1.04(0.97)/1.06=0.95169811\sigma_Y(8,4)=1.04(0.97)/1.06=0.95169811. Their product is 0.896711110.89671111, equal to 1.04(0.9312)/1.081.04(0.9312)/1.08. The intermediate R(4)R(4) cancels. Replacing both endpoint factors by one common conversion would fail whenever the conversion runs with scale.

    2. Change the operator normalization

    Replace each PLP_L by 1−γ51-\gamma_5 in the definition of QQ. What changes in the matrix element, coefficient, step factors and uncertainty of the product?

    Solution

    Each current doubles, so Q′=4QQ'=4Q. Therefore M′=4M\mathcal M'=4\mathcal M and C′=C/4C'=C/4. Both matrix elements in a step ratio acquire the same factor, leaving σ\sigma unchanged. The matrix-element covariance scales consistently by the factors applied to its rows and columns; its relative uncertainty is unchanged. The product and its propagated absolute uncertainty are identical. Importing a source's matrix element while retaining the old coefficient would instead produce a factor-four error, even with otherwise correct running.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.