- Home
- Library
- Renormalization and Effective Field Theory
- Soft and Collinear Fields, Rapidity and Evolution
- Matching and Evolution across Several Scales
Matching and Evolution across Several Scales
A useful multiscale prediction must do more than identify a large logarithm. It must specify the matched operator, its boundary conditions, the evolution accuracy and the low-energy matrix element. We complete the massive-boson Sudakov example and calculate its leading-logarithmic suppression.
Preparation. Read rapidity renormalization and coefficient evolution. The observable here is a spacelike fermion-current form factor, an amplitude. Squaring it without including real radiation does not produce an infrared-inclusive scattering cross section.
First reproduce the one-loop form factor
Use the previous pages' , and . The massless hard matching coefficient in the site's amplitude normalization is
It is obtained by subtracting the infrared-identical effective current matrix element from the full current vertex. Its finite terms are the spacelike continuation of the quark-current coefficient in Becher, Broggio and Ferroglia 2015, §5, Eqs. (5.1)–(5.5), printed p. 48 (PDF). The low-scale factor, including the two external legs, is
Multiplying through first order gives
Both and have canceled. This is the leading-power one-loop contribution from the massive gauge exchange in the stated theory, with massless external fermions and no Yukawa interaction. The term is negative: virtual radiation suppresses the amplitude. The finite constant depends on the specified external-leg and coupling convention; it is not fixed by the anomalous dimension alone.
Match at the natural scales, then evolve
The hard current satisfies
where and likewise for . At LL in exponent counting, retain the one-loop cusp and one-loop beta function, omit noncusp terms, and use tree boundary coefficients. This definition specifies the ingredients instead of relying on a label alone.
Choose the natural endpoints , . In the rapidity representation one can evolve the soft and collinear rapidity scales together at , where their one-loop rapidity anomalous dimensions vanish. The remaining LL result is
The integration runs downward, so the exponent is negative for a positive cusp anomalous dimension. Another path in the plane gives the same answer when the rapidity anomalous dimension is integrated consistently. Boundary constants and noncusp logarithms enter beyond leading-logarithmic accuracy.
Evaluate the running-coupling integral
Let
The denominator must remain positive throughout the interval. Direct integration gives
For , the quotient tends to , so
Expanding the exponential reproduces the one-loop double logarithm derived from the actual sector integrals. Replacing the running coupling by its endpoint value throughout the integral generally gives a different logarithmic series.
For a definite running example, use an Abelian Stückelberg gauge-boson mass , one massless unit-charge Dirac species, and . The mass term is , invariant under , . In a covariant gauge that removes the quadratic mixing, and the Abelian ghosts are free. They introduce no charged scalar contribution to this beta coefficient; the massless fermion vacuum polarization fixes it. At one loop the exchanged-boson form factor is the Abelian specialization of the calculation above. Choose , ; these are illustrative perturbative inputs. The retained program integrates the cusp equation numerically and compares it with the analytic expression, including the continuous limit. It gives and . Freezing the coupling instead gives . The smaller infrared coupling in this Abelian example weakens the suppression.
| Running-coupling | Fixed-coupling | |
|---|---|---|
| 1 | 1 | 1 |
| 2 | 0.9879338903 | 0.9878399033 |
| 5 | 0.9372700724 | 0.9361671838 |
| 20 | 0.8016627885 | 0.7957012153 |
The rows near unity show the kernel’s limiting behavior; they are not predictions using a controlled power expansion.
Test intermediate-scale independence honestly
Define the LL transport between arbitrary endpoints by
For any perturbative intermediate
The equality follows from adjacent integrals and is checked numerically. Moving a matching boundary requires moving its boundary value too. If the hard boundary is relocated from to , use , not one. If the low boundary is relocated to , its translated factor is . Then
This is exact within the chosen LL evolution model. Setting both relocated boundaries to one instead leaves a calculable spurious scale dependence. In a genuine finite-order calculation, scale variation with consistently truncated boundary functions probes missing terms; exact all-order matching-scale independence is not a property to demand of every truncated expression.
When scales merge
At , and the LL kernel equals one. Finite matching terms remain, and the leading-power expansion is no longer controlled.
A prediction valid away from the Sudakov hierarchy must restore the full fixed-order result and subtract its overlap with the resummed approximation. For an amplitude through one loop,
Here “full” must include the actual finite-mass kinematics, not just the leading-power formula on this page. Both terms labeled NLO include the tree term, so it is not counted twice. Equivalently, write and subtract . The present calculation establishes the hierarchical form factor; it does not provide that finite-mass interpolation.
Exercises
1. Expand the LL exponent by one more logarithm
Expand the running-coupling result through first order in and identify the next term generated by running.
Solution
Since ,
The running term is . It is positive for the Abelian example's negative , because the coupling becomes smaller toward the infrared. This is distinct from the order- term produced by expanding the exponential itself.
2. An incorrect matching-scale variation
At fixed coupling, set a relocated hard boundary to one at , evolve to , and compare with the correctly transported result.
Solution
Writing , integration gives . The correct hard boundary has , which cancels the extra term. A boundary equal to one at every scale describes different approximations, not a test of the same matched prediction.
References
- Becher, Thomas, Alessandro Broggio, and Andrea Ferroglia. 2015. Introduction to Soft-Collinear Effective Theory. Lecture Notes in Physics 896; arXiv:1410.1892v3, §§5.1–5.2. Open PDF.
- Chiu, Jui-yu, Andreas Fuhrer, André H. Hoang, Randall Kelley, and Aneesh V. Manohar. 2009. “Soft-Collinear Factorization and Zero-Bin Subtractions.” Physical Review D 79, 053007, Eqs. (23)–(26). Open PDF.
- Chiu, Jui-yu, Ambar Jain, Duff Neill, and Ira Z. Rothstein. 2012. “A Formalism for the Systematic Treatment of Rapidity Logarithms in Quantum Field Theory.” Journal of High Energy Physics 05, 084; arXiv:1202.0814v2, §4.2. Open PDF.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.