Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Fixing the Coupling by a Measurement

    Two finite answers can disagree because their couplings describe different measurements. Match the inputs before comparing a second observable at the same perturbative order. For a massive scalar, we fix the threshold interaction and predict scattering away from threshold, distinguishing this physical input from a Euclidean zero-momentum condition.

    Preparation: The one-loop scalar amplitude. Use the common pole mass M>0M>0 and retain amplitudes through order λ2\lambda^2. In both scattering prescriptions the free internal mass is MM, with finite mass counterterms enforcing that pole; only the coupling subtraction differs. Thus λˉ\bar\lambda denotes a modified-MS coupling in an on-shell-mass organization. The threshold coupling is defined by the limiting massive amplitude, not a collision rate at exactly zero incident flux.

    Pole conditions and coupling conditions are different

    An on-shell mass scheme imposes that the two-point pole lie at M2M^2. A unit-residue field condition fixes a finite field normalization. Neither condition determines a four-point coupling: that requires an additional input.

    For the scalar model define the real threshold input

    λT:=−Re⁡M(4M2,0,0).\lambda_T:=-\operatorname{Re}\mathcal M(4M^2,0,0).

    The one-loop absorptive part vanishes at threshold. This coupling can be inferred from low-energy scattering, with the weak repulsive branch chosen to fix the sign; a cross section alone gives only its magnitude at leading order. It is a perturbative low-energy normalization, not a statement about nonperturbative four-dimensional ϕ4\phi^4 continuum existence.

    Let σT=lim⁡s↓4M2σ(s)\sigma_T=\lim_{s\downarrow4M^2}\sigma(s), extrapolated from nonzero relative momentum. Near threshold only the isotropic term survives for this massive short-range interaction. The identical-boson rate therefore gives, through the order used here,

    M2σT=λT2128π,λT=+128πM2σT.M^2\sigma_T=\frac{\lambda_T^2}{128\pi}, \qquad \lambda_T=+\sqrt{128\pi M^2\sigma_T}.

    For example, a threshold input M2σT=1/(128π)M^2\sigma_T=1/(128\pi) selects λT=1\lambda_T=1 on the repulsive branch. This is an illustrative input. Carry it to s=8M2s=8M^2 and 12M212M^2 without another fit.

    Let L=ln⁡(M2/μ2)L=\ln(M^2/\mu^2). The modified-MS amplitude at this point is −λˉ+λˉ2(2−3L)/(32π2)-\bar\lambda+\bar\lambda^2(2-3L)/(32\pi^2). Thus

    λT=λˉ−λˉ232π2(2−3L)+O(λˉ3),λˉ=λT+λT232π2(2−3L)+O(λT3).\boxed{\lambda_T=\bar\lambda-\frac{\bar\lambda^2}{32\pi^2}(2-3L)+O(\bar\lambda^3),\qquad \bar\lambda=\lambda_T+\frac{\lambda_T^2}{32\pi^2}(2-3L)+O(\lambda_T^3).}

    The inverse relation is a perturbative series. Solving the truncated quadratic exactly would add particular higher-order terms without calculating the other terms of that order.

    The second kinematic point

    Substitute the inverse map into the full amplitude and reexpand. The logarithm cancels against the finite coupling conversion:

    MT(s,t,u)=−λT+λT232π2[b(s)+b(t)+b(u)−2]+O(λT3).\boxed{\mathcal M_T(s,t,u)=-\lambda_T+\frac{\lambda_T^2}{32\pi^2}[b(s)+b(t)+b(u)-2]+O(\lambda_T^3).}

    Equivalently, subtract the regulated four-point loop at threshold. Its counterterm is

    δλT=λT232π2[3Δϵ−3L+2]+O(λT3).\delta\lambda_T=\frac{\lambda_T^2}{32\pi^2}[3\Delta_\epsilon-3L+2]+O(\lambda_T^3).

    The bare coupling in the two schemes agrees after inserting the finite map. No mass-parameter substitution is made inside this threshold bubble. A fully modified-MS propagator mass differs from MM perturbatively, but expanding its square-root threshold is nonuniform when ss is within the mass shift of 4M24M^2. The pole-mass organization fixes the cut at the same physical location in both calculations.

    For a concrete second point, choose s=8M2s=8M^2 and scattering angle cos⁡θ=0\cos\theta=0, so t=u=−2M2t=u=-2M^2. Then

    MT=−λT+λT232π2[b(8M2)+2b(−2M2)−2]+O(λT3),\mathcal M_T=-\lambda_T+\frac{\lambda_T^2}{32\pi^2}[b(8M^2)+2b(-2M^2)-2]+O(\lambda_T^3),

    where

    b(8M2)=2−12ln⁡2+12−1+iπ2,b(−2M2)=2−3ln⁡3+13−1.b(8M^2)=2-\frac1{\sqrt2}\ln\frac{\sqrt2+1}{\sqrt2-1}+\frac{i\pi}{\sqrt2},\qquad b(-2M^2)=2-\sqrt3\ln\frac{\sqrt3+1}{\sqrt3-1}.

    These are finite, explicit numbers. The real part changes the one-loop rate; the imaginary part satisfies the two-particle unitarity relation. No new renormalization condition is fitted at this second point.

    Euclidean momentum subtraction is another coordinate

    A Euclidean zero-momentum prescription instead defines λE=λMOM\lambda_E=\lambda_{\rm MOM} from the four-point proper vertex at all external Euclidean momenta zero, with a declared field normalization. For the same one-loop scalar field normalization, the channel bubbles are all B(0)B(0):

    λE=λˉ+3λˉ2L32π2+O(λˉ3)=λT+λT216π2+O(λT3).\lambda_E=\bar\lambda+\frac{3\bar\lambda^2L}{32\pi^2}+O(\bar\lambda^3)=\lambda_T+\frac{\lambda_T^2}{16\pi^2}+O(\lambda_T^3).

    Eliminating λˉ\bar\lambda gives the last relation. Euclidean zero momentum is not on-shell massive 2→22\to2 kinematics: s+t+u=0s+t+u=0 there, while s+t+u=4M2s+t+u=4M^2 physically. Calling the Euclidean coupling a measured threshold amplitude would miss λT2/(16π2)\lambda_T^2/(16\pi^2).

    More general MOM conditions use a specified nonexceptional Euclidean configuration and specified external field normalization. Each produces a corresponding finite map, potentially depending on M/μM/\mu. They are not all interchangeable definitions of one universal “MOM coupling.”

    MS versus modified MS

    At the same dimensional scale μ\mu, MS subtracts 1/ϵ1/\epsilon, while modified MS subtracts Δϵ\Delta_\epsilon. Let c=ln⁡4π−γEc=\ln4\pi-\gamma_E. Equality of the bare coupling gives

    λMS=λˉ+3cλˉ232π2+O(λˉ3).\lambda_{\rm MS}=\bar\lambda+\frac{3c\bar\lambda^2}{32\pi^2}+O(\bar\lambda^3).

    The extra 3c3c retained in the MS loop amplitude then cancels this finite shift of its tree term. Equivalently, when changing the scale label along with the subtraction convention, the MS loop at scale μ\mu has the same finite logarithm as the modified-MS loop at μˉ2=4πe−γEμ2\bar\mu^2=4\pi e^{-\gamma_E}\mu^2. State whether scales or couplings are being relabeled; doing both inadvertently counts the conversion twice.

    A mass-dependent physical scheme and a mass-independent subtraction scheme need not have identical beta functions away from an asymptotic regime. The threshold measurement fixes λT\lambda_T even as μ\mu changes in the calculation; the logarithm in its relation to λˉ\bar\lambda compensates the running. The scheme transformation of the beta function differentiates this particular map at fixed pole mass.

    What a residual difference means

    An amplitude calculated to one loop is known through O(λT2)O(\lambda_T^2); its rate is known through O(λT3)O(\lambda_T^3). If one inserts the finite coupling map but does not reexpand the two truncated rates, their difference begins at O(λT4)O(\lambda_T^4). This difference is a collection of incomplete higher-order terms, not a new physical effect.

    At s=8M2s=8M^2, cos⁡θ=0.23\cos\theta=0.23, μ=2M\mu=2M, the retained numerical calculation compares the two unexpanded squared amplitudes after the one-loop map. Halving λT\lambda_T from 0.40.4 successively gives ratios of differences 16.037316.0373, 16.018816.0188, 16.009516.0095, approaching the 242^4 scaling expected for order λT4\lambda_T^4. Reexpanding instead makes their coefficients through cubic order identical algebraically.

    Summary

    Physical threshold, Euclidean MOM, MS and modified MS define distinct coordinates on the same regulated theory. Matching one input and reexpanding a second prediction removes scheme differences through the calculated order; unmatched couplings do not test scheme independence.

    With the threshold coupling fixed, integrate the angular distribution at two higher energies. Those two rates test the energy dependence with the same measured input.

    Exercises

    1. An apparent disagreement at the mass scale

    At μ=M\mu=M, two authors choose λT=1\lambda_T=1 and λˉ(M)=1\bar\lambda(M)=1, respectively. Do their one-loop threshold amplitudes agree?

    Solution

    The predictions are −1-1 and −1+1/(16π2)-1+1/(16\pi^2): the inputs were not matched. To represent λT=1\lambda_T=1, use λˉ(M)=1+1/(16π2)+O(λT3)\bar\lambda(M)=1+1/(16\pi^2)+O(\lambda_T^3) as the perturbative map and reexpand. The finite correction then cancels.

    2. Transform a beta function

    Let λ′=λ+aλ2\lambda'=\lambda+a\lambda^2 with constant aa and β(λ)=bλ2+cλ3+O(λ4)\beta(\lambda)=b\lambda^2+c\lambda^3+O(\lambda^4). Find β′(λ′)\beta'(\lambda') through cubic order. What extra term appears if a=a(μ)a=a(\mu)?

    Solution

    At constant aa, the chain rule gives β′=(1+2aλ)(bλ2+cλ3)\beta'=(1+2a\lambda)(b\lambda^2+c\lambda^3). Invert λ=λ′−aλ′2+⋯\lambda=\lambda'-a\lambda'^2+\cdots; the 2ab2ab terms cancel:

    β′(λ′)=bλ′2+cλ′3+O(λ′4).\beta'(\lambda')=b\lambda'^2+c\lambda'^3+O(\lambda'^4).

    If the map depends explicitly on scale, add (μ da/dμ)λ2(\mu\,\mathrm da/\mathrm d\mu)\lambda^2 before reexpressing it; even the leading coefficient can change. A threshold coupling at fixed physical inputs is scale independent only when this derivative of its modified-MS map is included.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.