    A heavy particle can leave a mass term in a low-energy theory even when it cannot be produced. How large is that term, and does its sign depend on how we subtract the loop? We will calculate one threshold in three prescriptions and compare the same inputs.

    Preparation: Scalar mass renormalization and functional matching. We work perturbatively in flat spacetime, at external momenta much smaller than the heavy mass. A light pole is assumed to remain in this regime after matching.

    Fix the model and the mass definition

    Take two real scalars with canonical kinetic terms and

    V(ϕ,H)=12m>2ϕ2+12M2H2+λ24ϕ4+κ4ϕ2H2.V(\phi,H)=\frac12m_>^2\phi^2+\frac12M^2H^2+\frac{\lambda}{24}\phi^4+\frac{\kappa}{4}\phi^2H^2.

    Here M2>0M^2>0, λ,κ≥0\lambda,\kappa\geq0, and the expansion is about the symmetric vacuum. Choose the renormalized light input so that this vacuum and its small positive pole mass survive. The label >> denotes the theory containing HH, not a bare parameter. The EFT below MM contains a mass m<2m_<^2. At the order considered, the distinction between the heavy renormalized and pole mass changes the result only at higher order at fixed nonexceptional kinematics.

    The interaction vertex is −iκ-i\kappa. A heavy tadpole attached to two external ϕ\phi lines has symmetry factor 1/21/2. Using D=4−2ϵD=4-2\epsilon and the site conventions, write the propagator insertion as −iΣH-i\Sigma_H. Then

    A(M2)=μ2ϵi∫dDk(2π)D1k2−M2+i0=M216π2(Δϵ+1−ln⁡M2μ2),ΣH,loop=−κ2A(M2),A(M^2)=\frac{\mu^{2\epsilon}}{i}\int\frac{\mathrm d^D k}{(2\pi)^D}\frac1{k^2-M^2+i0}=\frac{M^2}{16\pi^2}\left(\Delta_\epsilon+1-\ln\frac{M^2}{\mu^2}\right),\qquad \Sigma_{H,\rm loop}=-\frac\kappa2 A(M^2),

    where Δϵ=1/ϵ−γE+ln⁡4π\Delta_\epsilon=1/\epsilon-\gamma_E+\ln4\pi and terms vanishing with ϵ\epsilon are omitted. This sign follows by multiplying the vertex, propagator and symmetry factor; the sign of a memorized Euclidean integral alone would not determine it. The mass counterterm δm2=κM2Δϵ/(32π2)\delta m^2=\kappa M^2\Delta_\epsilon/(32\pi^2) gives

    ΣHMS‾=κM232π2(ln⁡M2μ2−1).\Sigma_H^{\overline{\rm MS}}=\frac{\kappa M^2}{32\pi^2}\left(\ln\frac{M^2}{\mu^2}-1\right).

    This diagram has no external-momentum dependence, hence no heavy field-residue correction at order κ\kappa.

    Match a common low-energy pole

    The full and effective theories have the same light diagrams to this accuracy. Equating their inverse two-point functions therefore gives

    m<2(μ)=m>2(μ)+κM232π2(ln⁡M2μ2−1)+O(κ2,κλ).m_<^2(\mu)=m_>^2(\mu)+\frac{\kappa M^2}{32\pi^2}\left(\ln\frac{M^2}{\mu^2}-1\right)+O(\kappa^2,\kappa\lambda).

    The displayed correction is a matching coefficient in a stated scheme. In particular, it is negative at μ=M\mu=M. It is not an independently measurable negative contribution to a mass: the measurable pole includes the matched parameter and the remaining light corrections.

    An independent derivation differentiates the heavy determinant. At a constant light background its squared mass is u=M2+κϕ2/2u=M^2+\kappa\phi^2/2, and the renormalized one-loop potential is

    V1,H=u264π2(ln⁡uμ2−32).V_{1,H}=\frac{u^2}{64\pi^2}\left(\ln\frac u{\mu^2}-\frac32\right).

    Since u′(0)=0u'(0)=0 and u′′(0)=κu''(0)=\kappa, differentiating twice gives exactly ΣHMS‾\Sigma_H^{\overline{\rm MS}}. This comparison fixes both the factor of two associated with a real heavy field and the potential-to-mass normalization. In a Lorentzian Lagrangian this potential appears with a minus sign.

    The explicit scale derivative of the threshold is −κM2/(16π2)-\kappa M^2/(16\pi^2). Consequently the heavy contribution to the high-energy mass beta function is +κM2/(16π2)+\kappa M^2/(16\pi^2), canceling that derivative in the low-energy relation. Running of MM and κ\kappa inside this one-loop term contributes at higher loop order. With additive mass renormalization it is clearer to use βm2\beta_{m^2} directly than to divide by a mass that might pass through zero.

    Move a finite term without changing the theory

    Choose instead

    δmc2=κM232π2(Δϵ+c),mc2=m>2−cκM232π2.\delta m_c^2=\frac{\kappa M^2}{32\pi^2}(\Delta_\epsilon+c),\qquad m_c^2=m_>^2-c\frac{\kappa M^2}{32\pi^2}.

    The second relation holds because the bare mass is unchanged. The renormalized loop becomes

    ΣH,c=κM232π2(ln⁡M2μ2−1+c),mc2+ΣH,c=m>2+ΣHMS‾.\Sigma_{H,c}=\frac{\kappa M^2}{32\pi^2}\left(\ln\frac{M^2}{\mu^2}-1+c\right),\qquad m_c^2+\Sigma_{H,c}=m_>^2+\Sigma_H^{\overline{\rm MS}}.

    For c=1c=1 the explicit threshold vanishes at μ=M\mu=M, while the high-energy mass coordinate changes by the old threshold. This does not remove the relation between the common low-energy pole and the specified high-energy inputs. Holding the numerical value of mc2m_c^2 equal to the old m>2m_>^2 would instead compare different theories.

    The cutoff calculation with converted inputs

    A spherical Euclidean momentum cutoff gives the positive integral

    IΛ(M2)=∫kE2<Λ2d4kE(2π)41kE2+M2=Λ2−M2ln⁡(1+Λ2/M2)16π2.I_\Lambda(M^2)=\int_{k_E^2<\Lambda^2}\frac{\mathrm d^4k_E}{(2\pi)^4}\frac1{k_E^2+M^2}=\frac{\Lambda^2-M^2\ln(1+\Lambda^2/M^2)}{16\pi^2}.

    It follows directly from the radial measure k3dk/(8π2)k^3\mathrm dk/(8\pi^2). The unrenormalized mass correction is κIΛ/2\kappa I_\Lambda/2. To match the previous subtraction convention, choose

    δmΛ2=κ32π2[−Λ2+M2ln⁡Λ2μ2−M2].\delta m_\Lambda^2=\frac{\kappa}{32\pi^2}\left[-\Lambda^2+M^2\ln\frac{\Lambda^2}{\mu^2}-M^2\right].

    Adding the two expressions produces

    κ2IΛ+δmΛ2=κM232π2[ln⁡M2μ2−1−ln⁡(1+M2Λ2)].\frac\kappa2I_\Lambda+\delta m_\Lambda^2=\frac{\kappa M^2}{32\pi^2}\left[\ln\frac{M^2}{\mu^2}-1-\ln\left(1+\frac{M^2}{\Lambda^2}\right)\right].

    Thus the converted result tends to the dimensional-regularization answer, with an error −κM4/(32π2Λ2)+O(Λ−4)-\kappa M^4/(32\pi^2\Lambda^2)+O(\Lambda^{-4}). The regulator-dependent quadratic term has canceled. If a finite cutoff instead represents actual new dynamics, this counterterm cannot be inferred without specifying that dynamics and its matching data.

    What the threshold establishes

    For a fixed high-energy mass prescription and fixed κ\kappa, changing the heavy physical mass changes the low-energy matching relation by a quantity of order κM2/(16π2)\kappa M^2/(16\pi^2). Low-energy decoupling does not require suppression of a relevant operator's coefficient by 1/M1/M. Once that coefficient has been measured and matched, heavy effects in higher-dimension interactions are suppressed in the usual low-energy expansion.

    This calculation establishes sensitivity under stated input variations. Whether the inputs are independent, symmetry-related or statistically distributed is additional information, developed in symmetry protection and parameter choices.

    Exercises

    1. A converted regulator sequence. At μ=M\mu=M, compare the finite-cutoff answer with the dimensional answer for Λ/M=5,10,20\Lambda/M=5,10,20. Express the error in units κM2/(32π2)\kappa M^2/(32\pi^2) and bound its magnitude.

    Solution

    The error is −ln⁡(1+M2/Λ2)-\ln(1+M^2/\Lambda^2), giving −0.0392207-0.0392207, −0.00995033-0.00995033 and −0.00249688-0.00249688. Since 0<ln⁡(1+x)<x0<\ln(1+x)<x for x>0x>0, its magnitude is less than M2/Λ2M^2/\Lambda^2. Successive ratios approach four, consistent with the first omitted inverse-cutoff power. Subtracting only Λ2\Lambda^2 would retain an uncanceled logarithm and would not compare the same renormalized prescription.

    2. A numerical finite-scheme change. With M=10 TeVM=10\,\mathrm{TeV}, κ=0.1\kappa=0.1, μ=M\mu=M, neglect common light loops. Find the high-energy mass squared giving m<2=0.0100 TeV2m_<^2=0.0100\,\mathrm{TeV}^2. Repeat for c=1c=1.

    Solution

    The quantity b=κM2/(32π2)b=\kappa M^2/(32\pi^2) is 0.0316629 TeV20.0316629\,\mathrm{TeV}^2. In the first scheme m>2=m<2+b=0.0416629 TeV2m_>^2=m_<^2+b=0.0416629\,\mathrm{TeV}^2. In the second, m12=m>2−b=0.0100 TeV2m_1^2=m_>^2-b=0.0100\,\mathrm{TeV}^2 and the explicit threshold is zero. Both give the same low-energy mass. Keeping 0.04166290.0416629 as the second scheme's input would change the low-energy mass and fail the fixed-input comparison.

    Summary

    A real heavy scalar generates a calculable local mass threshold. Its finite split between a renormalized input and a loop depends on the subtraction prescription; their sum does not. Dimensional and cutoff regulators agree after converting the counterterms and inputs. The physical question concerns specified heavy thresholds and input relations, not an isolated regulator power divergence.

    References

    • Nathaniel Craig, Naturalness: A Snowmass White Paper, §2.1 and §5: radiative stability, symmetry and the interpretation of heavy thresholds. The scalar normalization and subtraction comparison above are derived explicitly here.
    • Stephen P. Martin, A Supersymmetry Primer, §7.3, equations (7.3.4)–(7.3.6): one-loop supertrace potential; one real scalar supplies the determinant used above.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.