Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Running Coefficients and Matrix Elements

    A quark matrix element and its Wilson coefficient can each change with the subtraction scale while their contribution to a prediction stays fixed. The cancellation works only when coefficients evolve in the dual representation. We solve the quark–gluon two-operator example and then change to a moving basis where matrix ordering becomes unavoidable.

    Preparation: The spin-two mixing matrix and running couplings. Operators and coefficients are columns, OB=ZORO_B=ZO_R, γ=Z−1DZ\gamma=Z^{-1}\mathcal DZ, and DOR=−γOR\mathcal D O_R=-\gamma O_R. A transpose below is an ordinary transpose, not a complex conjugate; a non-Hermitian interaction separately needs its Hermitian conjugate.

    The coefficient equation is forced

    Let a local effective Hamiltonian contain CTOC^{\mathsf T}O. Canonical heavy-scale factors, if present, are included in CC. Fixed-bare scale independence gives

    0=D(CTO)=(DC)TO−CTγO,DC=γTC.0=\mathcal D(C^{\mathsf T}O)=(\mathcal DC)^{\mathsf T}O-C^{\mathsf T}\gamma O,\qquad \boxed{\mathcal DC=\gamma^{\mathsf T}C.}

    In indices, DCi=γjiCj\mathcal DC_i=\gamma_{ji}C_j. Matrix elements between fixed physical states evolve with the operator equation. Consequently A=CT⟨f∣O∣i⟩\mathcal A=C^{\mathsf T}\langle f|O|i\rangle has zero scale derivative through the computed order. Elementary-field factors in an amputated off-shell Green function require their own accounting; this equation concerns the renormalized operator matrix elements, not an arbitrarily amputated tensor.

    Set t=ln⁡(μ/μ0)t=\ln(\mu/\mu_0). For general running matrices,

    U˙=−γ(t)U,U(0)=1,O(t)=U(t)O(0),C(t)=U(t)−TC(0).\dot U=-\gamma(t)U,\qquad U(0)=\mathbf1,\qquad O(t)=U(t)O(0),\qquad C(t)=U(t)^{-\mathsf T}C(0).

    Differentiate U−1U=1U^{-1}U=1 to get U˙−1=U−1γ\dot U^{-1}=U^{-1}\gamma; transposition proves the coefficient equation. The ordered solution places later scales to the left:

    U(t2,t0)=U(t2,t1)U(t1,t0)=Pexp⁡[−∫t0t2dt γ(t)].U(t_2,t_0)=U(t_2,t_1)U(t_1,t_0)=\mathcal P\exp\left[-\int_{t_0}^{t_2}dt\,\gamma(t)\right].

    Pairing invariance alone is not enough to test the ordering: any invertible wrong matrix VV paired with V−TV^{-\mathsf T} preserves the scalar. The differential equation or composition law must also be checked.

    A two-operator probe with a known solution

    Use the physical forward spin-two block,

    γ(t)=αs(t)πK,K=(A−B−AB),A=43CF,B=23nfTF.\gamma(t)=\frac{\alpha_s(t)}\pi K,\qquad K=\begin{pmatrix}A&-B\\-A&B\end{pmatrix},\qquad A=\frac43C_F,\quad B=\frac23n_fT_F.

    A weak prescribed symmetric external source can couple to CqOqμν+CgOgμνC_qO_q^{\mu\nu}+C_gO_g^{\mu\nu}. This need not be a dynamical massless graviton. Dividing its forward matrix element by the common tensor normalization leaves the response R=Cqfq+Cgfg\mathcal R=C_qf_q+C_gf_g. The coefficients must come from a matching or normalization condition at μ0\mu_0; evolution does not determine that input or the nonperturbative hadron fractions.

    At leading order α˙s=−β0αs2/(2π)\dot\alpha_s=-\beta_0\alpha_s^2/(2\pi). For β0>0\beta_0>0,

    αs(t)=α01+β0α0t/(2π),τ(t)=∫0tαs(t′)πdt′=2β0ln⁡α0αs(t).\alpha_s(t)=\frac{\alpha_0}{1+\beta_0\alpha_0t/(2\pi)},\qquad \tau(t)=\int_0^t\frac{\alpha_s(t')}{\pi}dt'=\frac2{\beta_0}\ln\frac{\alpha_0}{\alpha_s(t)}.

    Since K2=(A+B)KK^2=(A+B)K, the exponential reduces to

    U=1+e−(A+B)τ−1A+BK,U−T=1+e+(A+B)τ−1A+BKT.U=\mathbf1+\frac{e^{-(A+B)\tau}-1}{A+B}K,\qquad U^{-\mathsf T}=\mathbf1+\frac{e^{+(A+B)\tau}-1}{A+B}K^{\mathsf T}.

    For fq+fg=1f_q+f_g=1, define r=e−(A+B)τr=e^{-(A+B)\tau}. Then

    fq(t)=BA+B+r[fq(0)−BA+B],fg(t)=1−fq(t).f_q(t)=\frac B{A+B}+r\left[f_q(0)-\frac B{A+B}\right],\qquad f_g(t)=1-f_q(t).

    The nonconserved fraction decays toward the stationary column. The corresponding coefficient combination grows inversely, so their contraction stays fixed. Decompose the coefficient into the two left-eigenoperator rows, written as columns:

    C(0)=u(11)+v(A−B),u=BCq(0)+ACg(0)A+B,v=Cq(0)−Cg(0)A+B.C(0)=u\begin{pmatrix}1\\1\end{pmatrix}+v\begin{pmatrix}A\\-B\end{pmatrix},\qquad u=\frac{BC_q(0)+AC_g(0)}{A+B},\quad v=\frac{C_q(0)-C_g(0)}{A+B}.

    Then C(t)=u(1,1)T+vr−1(A,−B)TC(t)=u(1,1)^{\mathsf T}+vr^{-1}(A,-B)^{\mathsf T}. In particular a source coupling to the total stress tensor, Cq=CgC_q=C_g, has constant coefficients.

    For an illustrative input, choose Nc=3N_c=3, nf=3n_f=3, μ0=2 GeV\mu_0=2\,\mathrm{GeV}, α0=0.25\alpha_0=0.25, f(0)=(0.6,0.4)Tf(0)=(0.6,0.4)^{\mathsf T} and C(0)=(2,−1)TC(0)=(2,-1)^{\mathsf T}. These fractions are assumed numbers, not a fit to hadron data. At μ=20 GeV\mu=20\,\mathrm{GeV} the leading solution is

    αs=0.137019896,f=(0.5255783700.474421630),C=(2.86297220−1.48542186),R=0.8.\alpha_s=0.137019896,\qquad f=\begin{pmatrix}0.525578370\\0.474421630\end{pmatrix},\qquad C=\begin{pmatrix}2.86297220\\-1.48542186\end{pmatrix},\qquad \mathcal R=0.8.

    Solving the coupled differential equations independently checks this closed solution. Using U−1U^{-1} instead of U−TU^{-\mathsf T} for the coefficient gives R≃0.614444\mathcal R\simeq0.614444, an error visible precisely because KK is nonsymmetric.

    Quark and gluon fractions evolve in opposite directions while the two coefficient-weighted contributions change with a constant sum.

    Leading fixed-flavor evolution for the illustrative input above. The separate contributions CqfqC_qf_q and CgfgC_gf_g depend on scale; their sum is 0.80.8. The curve is a perturbative evolution example, not a determination of hadron momentum fractions.

    A moving basis creates noncommuting matrices

    The leading matrix above commutes with itself at different scales. To test the general formula on the same physical system, make an explicitly scale-dependent finite coordinate change,

    O′=R(t)O,R(t)=(1ρt01),C′=R−TC,ρ=0.4.O'=R(t)O,\qquad R(t)=\begin{pmatrix}1&\rho t\\0&1\end{pmatrix},\qquad C'=R^{-\mathsf T}C,\qquad \rho=0.4.

    This is a chosen moving basis, not an additional physical interaction or a claim about a new QCD subtraction calculation. Differentiation gives

    γ′(t)=αs(t)πR(t)KR(t)−1−(0ρ00),U′(t,0)=R(t)U(t,0).\gamma'(t)=\frac{\alpha_s(t)}\pi R(t)KR(t)^{-1}-\begin{pmatrix}0&\rho\\0&0\end{pmatrix},\qquad U'(t,0)=R(t)U(t,0).

    The matrices γ′(t1)\gamma'(t_1) and γ′(t2)\gamma'(t_2) generally do not commute. Direct integration of U˙′=−γ′U′\dot U'=-\gamma'U' reproduces the endpoint expression. Replacing it by exp⁡[−∫γ′dt]\exp[-\int\gamma' dt] does not; dropping the derivative term also solves a different problem. Both failures are explicitly tested in the companion calculation. Pairing a wrong solution with its own inverse transpose would conceal them if no endpoint or differential check were made.

    For a general map with R(0)≠1R(0)\ne1, both endpoints enter:

    U′(t,0)=R(t)U(t,0)R(0)−1,C′(t)=R(t)−TU(t,0)−TR(0)TC′(0).U'(t,0)=R(t)U(t,0)R(0)^{-1},\qquad C'(t)=R(t)^{-\mathsf T}U(t,0)^{-\mathsf T}R(0)^{\mathsf T}C'(0).

    A constant finite scheme transformation is the simpler special case. Matching coefficients and matrix elements in different schemes without these maps produces a false physical scale or basis dependence.

    Fixed order versus leading-log evolution

    The exponential resums leading logarithms from the displayed one-loop matrix and beta function. It is not an exact QCD prediction. Expanding over a short interval with h=α0t/πh=\alpha_0t/\pi gives

    f(t)=(1−hK)f(0)+O(α02t,α02t2),C(t)=(1+hKT)C(0)+O(α02t,α02t2).f(t)=(1-hK)f(0)+O(\alpha_0^2t,\alpha_0^2t^2),\qquad C(t)=(1+hK^{\mathsf T})C(0)+O(\alpha_0^2t,\alpha_0^2t^2).

    Their product cancels at order hh. Multiplying just the displayed truncated factors retains −h2C(0)TK2f(0)-h^2C(0)^{\mathsf T}K^2f(0), which is beyond that fixed-order accuracy. The exact cancellation in the leading-log numerical example checks the solution of its specified evolution equations, not the absence of higher-order matching or matrix-element corrections. Flavor thresholds require a new matching step.

    The contraction CT⟨O⟩C^{\mathsf T}\langle O\rangle also occurs when the input matrix element comes from a finite lattice. The correlated step-scaling calculation follows its normalization and error through conversion to a common scheme.

    Summary

    Wilson coefficients follow +γT+\gamma^{\mathsf T} because operators follow −γ-\gamma. A nonsymmetric physical mixing matrix tests that statement directly. In a moving basis, the derivative connection and endpoint maps are essential, and pairing invariance must be supplemented by a check of the actual evolution equation.

    Exercises

    1. A pure total-stress coupling

    Take C(0)=(c,c)TC(0)=(c,c)^{\mathsf T} and arbitrary fq(0)+fg(0)=1f_q(0)+f_g(0)=1. Find the response at any scale in the leading example, including in the moving basis.

    Solution

    Since KT(1,1)T=0K^{\mathsf T}(1,1)^{\mathsf T}=0, C(t)=c(1,1)TC(t)=c(1,1)^{\mathsf T} and R=c(fq+fg)=c\mathcal R=c(f_q+f_g)=c. In the moving basis, C′=c(1,1−ρt)TC'=c(1,1-\rho t)^{\mathsf T} and f′=(fq+ρtfg,fg)Tf'=(f_q+\rho t f_g,f_g)^{\mathsf T}. Their contraction is again cc. Constant physical coupling does not imply constant coordinate components in a moving basis.

    2. Diagnose the first uncanceled term

    At fixed short-interval hh, multiply f=(1−hK)f0f=(1-hK)f_0 by C=(1+hKT)C0C=(1+hK^{\mathsf T})C_0. How does the residual scale under h→h/2h\to h/2? Would applying the same sign to both flows improve it?

    Solution

    The product is C0T(1+hK)(1−hK)f0=C0Tf0−h2C0TK2f0C_0^{\mathsf T}(1+hK)(1-hK)f_0=C_0^{\mathsf T}f_0-h^2C_0^{\mathsf T}K^2f_0. The residual decreases by four when hh is halved, unless that matrix element accidentally vanishes. Using C=(1−hKT)C0C=(1-hK^{\mathsf T})C_0 instead leaves −2hC0TKf0-2hC_0^{\mathsf T}Kf_0 already at the calculated order. A higher-order residual and an order-hh convention error are distinguishable by this scaling test.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.