Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Electroweak Vacuum Stability

    A positive Higgs quartic at the weak scale does not guarantee that the same running coupling remains positive at much higher scales. Fermion and gauge fluctuations compete with the scalar interaction. We will integrate a specified one-loop trajectory, vary its inputs and then distinguish a zero of a running parameter from a physical vacuum-decay prediction.

    Preparation: The Higgs potential, renormalization schemes and beta functions.

    Physical inputs must be matched first

    Write V=−μH2H†H+λ(H†H)2V=-\mu_H^2H^\dagger H+\lambda(H^\dagger H)^2. At tree level the radial Higgs mass gives λ=Mh2/(2v2)\lambda=M_h^2/(2v^2). In a loop calculation, a measured mass and a running coefficient are different quantities. Schematically, with vF=(2GF)−1/2v_F=(\sqrt2G_F)^{-1/2},

    λMS‾(μ)=Mh22vF2+δλmatch(μ),yt(μ)=2MtvF [1+δt(μ)].\lambda_{\overline{\mathrm{MS}}}(\mu)=\frac{M_h^2}{2v_F^2}+\delta\lambda_{\mathrm{match}}(\mu),\qquad y_t(\mu)=\frac{\sqrt2M_t}{v_F}\,[1+\delta_t(\mu)].

    The finite matching terms depend on the chosen observables, perturbative order and tadpole/input prescription. For example, the one-loop QCD mass conversion at μ=Mt\mu=M_t contributes δt=−4αs/(3π)\delta_t=-4\alpha_s/(3\pi) before the remaining electroweak and input-conversion terms. A collider mass parameter also requires a stated relation to a field-theory mass definition. Replacing all these steps by a tree relation can move a high-scale crossing substantially.

    Buttazzo et al. §2 derive matching by equating bare quantities in on-shell and MS‾\overline{\mathrm{MS}} prescriptions. We use that distinction, but do not reproduce their precision matching calculation or adopt their historical numerical input fit. The following benchmark starts directly from running coordinates and is completely specified as such.

    A one-loop benchmark that can be reproduced

    Let t=log⁡(μ/μ0)t=\log(\mu/\mu_0), with μ0=173 GeV\mu_0=173\,\mathrm{GeV}. Use the Standard Model particle content above that scale and neglect Yukawa couplings other than yty_t. Here gYg_Y has the Standard Model hypercharge normalization Q=T3+YQ=T^3+Y, not the grand-unified normalization. The one-loop equations are

    16π2dgYdt=416gY3,16π2dg2dt=−196g23,16π2dg3dt=−7g33,16\pi^2\frac{dg_Y}{dt}=\frac{41}{6}g_Y^3,\qquad 16\pi^2\frac{dg_2}{dt}=-\frac{19}{6}g_2^3,\qquad 16\pi^2\frac{dg_3}{dt}=-7g_3^3, 16π2dytdt=yt(92yt2−1712gY2−94g22−8g32),16\pi^2\frac{dy_t}{dt}=y_t\left(\frac92y_t^2-\frac{17}{12}g_Y^2-\frac94g_2^2-8g_3^2\right), 16π2dλdt=24λ2+(12yt2−9g22−3gY2)λ−6yt4+38[2g24+(g22+gY2)2].16\pi^2\frac{d\lambda}{dt}=24\lambda^2+(12y_t^2-9g_2^2-3g_Y^2)\lambda-6y_t^4 +\frac38\left[2g_2^4+(g_2^2+g_Y^2)^2\right].

    The 24λ224\lambda^2 term is the scalar contribution; the negative −6yt4-6y_t^4 term can drive the quartic downward. Gauge contributions affect both the quartic directly and the evolution of the Yukawa coupling. Holding yty_t fixed while running λ\lambda would miss an essential part of the calculation.

    Specify the boundary values

    (gY,g2,g3,yt,λ)μ0=(0.36,0.65,1.16,0.93,0.126).(g_Y,g_2,g_3,y_t,\lambda)_{\mu_0}=(0.36,0.65,1.16,0.93,0.126).

    These are illustrative MS‾\overline{\mathrm{MS}} coordinates, not a reported best fit. The one-loop system is integrated without additional thresholds to 1018 GeV10^{18}\,\mathrm{GeV}. That continuation is a model assumption; it excludes new fields or higher-dimensional interactions along the way.

    Scale in GeVλ(μ)\lambda(\mu)
    10310^30.09628130
    10610^60.02846077
    101010^{10}−0.01025999
    101810^{18}−0.02783994

    The first zero is μλ=3.4014830×108 GeV\mu_\lambda=3.4014830\times10^8\,\mathrm{GeV}. Repeating the same calculation while changing only the initial top Yukawa gives

    yt(μ0)y_t(\mu_0)First zero of λ\lambda, in GeVλ(1018 GeV)\lambda(10^{18}\,\mathrm{GeV})
    0.911.397952×10131.397952\times10^{13}−0.00451045
    0.933.401483×1083.401483\times10^8−0.02783994
    0.957.213342×1067.213342\times10^6−0.05213676

    Changing λ(μ0)\lambda(\mu_0) to 0.1210.121 or 0.1310.131 at fixed yt=0.93y_t=0.93 instead moves the crossing to 5.011687×1075.011687\times10^7 or 4.197463×109 GeV4.197463\times10^9\,\mathrm{GeV}. This sensitivity is a result of the stated flow, not an uncertainty band derived from experimental errors.

    Three specified one-loop quartic trajectories. A larger initial top Yukawa moves the zero crossing to a lower scale.

    The same initial quartic and gauge couplings, with three initial top Yukawa values. This is a sensitivity calculation in the stated one-loop model; the crossing scales are not current experimental bounds.

    The companion integrates the coupled system with an adaptive high-order solver and with a separate fixed-step fourth-order Runge–Kutta method. Using 40, 80 and 160 steps over the full logarithmic interval gives maximum endpoint discrepancies 5.76×10−85.76\times10^{-8}, 3.64×10−93.64\times10^{-9} and 2.28×10−102.28\times10^{-10} against the adaptive solution. The gauge couplings also obey the independently integrated formula

    1gi2(μ)=1gi2(μ0)−bi8π2log⁡μμ0,(bY,b2,b3)=(416,−196,−7).\frac1{g_i^2(\mu)}=\frac1{g_i^2(\mu_0)}-\frac{b_i}{8\pi^2}\log\frac\mu{\mu_0},\qquad (b_Y,b_2,b_3)=\left(\frac{41}{6},-\frac{19}{6},-7\right).

    This checks the logarithm, normalization and numerical integration. It does not estimate missing higher-loop corrections.

    What the crossing does and does not establish

    For a large radial background φ\varphi, a leading-log diagnostic is V(φ)≈λ(μ=φ)φ4/4V(\varphi)\approx\lambda(\mu=\varphi)\varphi^4/4. Negative λ\lambda suggests that the high-field region merits a stability analysis. This expression omits finite effective-potential terms, the background-field anomalous-dimension factor and higher-loop running. It is not a complete effective action.

    The background field and the off-shell effective potential depend on gauge fixing. At consistent order, physical comparisons of stationary vacuum energies and the decay rate must be gauge independent; a field value read from a plotted potential need not be. The MS‾\overline{\mathrm{MS}} running-coupling zero is also a scheme-dependent diagnostic, not a scheme-independent observable. Buttazzo et al. §4.3 explicitly distinguish such definitions. Changing a finite coupling convention without changing matching and the effective action consistently cannot produce a new physical stability verdict.

    A vacuum can be locally stable while another configuration has lower energy. That situation permits metastability, with a finite tunneling rate. A cosmological lifetime additionally depends on the rate integrated over a spacetime history and, in general, finite-temperature effects. A zero crossing alone determines neither the bounce nor the age of a vacuum.

    A calculable tunneling limit

    The large-field negative-quartic model provides a controlled analytic illustration of the exponent. Set V(φ)=−ℓφ4/4V(\varphi)=-\ell\varphi^4/4 with fixed ℓ>0\ell>0, ignore gravity and use an O(4)O(4)-symmetric Euclidean profile. Its equation and regular solution are

    φ′′+3rφ′=−ℓφ3,φB(r)=8ℓRr2+R2.\varphi''+\frac3r\varphi'=-\ell\varphi^3,\qquad \varphi_B(r)=\sqrt{\frac8\ell}\frac{R}{r^2+R^2}.

    The profile is regular at r=0r=0 and tends to zero at infinity. Direct substitution verifies the equation for every R>0R>0. Its Euclidean action is

    B=2π2∫0∞dr r3[12(φB′)2−ℓ4φB4]=8π23ℓ.B=2\pi^2\int_0^\infty dr\,r^3\left[\frac12(\varphi_B')^2-\frac\ell4\varphi_B^4\right] =\frac{8\pi^2}{3\ell}.

    For example, after r=Rur=Ru, the dimensionless integrals are ∫0∞u5/(1+u2)4du=1/6\int_0^\infty u^5/(1+u^2)^4du=1/6 and ∫0∞u3/(1+u2)4du=1/12\int_0^\infty u^3/(1+u^2)^4du=1/12. The kinetic term is 16π2/(3ℓ)16\pi^2/(3\ell) and the potential term is −8π2/(3ℓ)-8\pi^2/(3\ell). For ℓ=0.02\ell=0.02, separate numerical integration gives 2631.894507−1315.947253=1315.9472532631.894507-1315.947253=1315.947253.

    Classical scale invariance leaves RR undetermined. Running couplings and fluctuation effects remove that degeneracy. The fixed negative quartic has no electroweak mass barrier; this profile models the high-field part of the tunneling problem, rather than constructing the full electroweak bounce. A schematic rate is Γ/V∼R−4e−B\Gamma/V\sim R^{-4}e^{-B}, but its prefactor, selected radius and matching to the low-field vacuum require further work. Buttazzo et al. §6.3 explain how the bounce action enters a spacetime-integrated decay probability. The example here does not calculate a present-day Standard Model lifetime or include unknown ultraviolet or gravitational effects.

    Summary

    Vacuum stability combines matching, coupled running and a consistent effective-action calculation. The benchmark demonstrates how strongly a quartic crossing depends on input coordinates. The negative-quartic bounce demonstrates exponential suppression, while also showing why a running zero is insufficient to determine a lifetime.

    Exercises

    1. Translate the hypercharge convention

    Buttazzo et al. use g12=(5/3)gY2g_1^2=(5/3)g_Y^2 and tabulate several equations for squared couplings differentiated with respect to log⁡μ2\log\mu^2. Recover the hypercharge equation used above.

    Solution

    Their one-loop coefficient for dg12/dlog⁡μ2dg_1^2/d\log\mu^2 is (41/10)g14/(16π2)(41/10)g_1^4/(16\pi^2). Since

    dg12dlog⁡μ2=g1dg1dlog⁡μ,\frac{dg_1^2}{d\log\mu^2}=g_1\frac{dg_1}{d\log\mu},

    the coefficient of g13g_1^3 in the latter derivative is also 41/1041/10. Substituting g1=5/3 gYg_1=\sqrt{5/3}\,g_Y gives (41/10)(5/3)=41/6(41/10)(5/3)=41/6. Multiplying by an additional two after already converting the squared coupling would give the wrong beta function.

    2. Why a small quartic change matters

    Compare the fixed-quartic bounce actions at ℓ=0.02\ell=0.02 and ℓ=0.025\ell=0.025. At equal prefactors and radii, what is the ratio of the schematic decay rates?

    Solution

    The two actions are B1=1315.947253B_1=1315.947253 and B2=1052.757803B_2=1052.757803. Thus

    log⁡(Γ/V)2(Γ/V)1=B1−B2=263.189451.\log\frac{(\Gamma/V)_2}{(\Gamma/V)_1}=B_1-B_2=263.189451.

    The second rate is exponentially larger, even though both exponents are large. This comparison holds the prefactor and radius fixed by assumption; in an actual running theory those quantities must also be recalculated. It quantifies sensitivity without supplying a cosmological survival probability.

    References

    • D. Buttazzo et al., Investigating the near-criticality of the Higgs boson, §2, Eqs. (1)–(5) (matching); §4.3, printed pp. 19–20 (scheme/gauge distinctions); §6.3, Eqs. (80)–(87) (bounce and spacetime probability); Appendix B.1, B.2 and B.4 (one-loop terms translated above). No historical fit or current stability classification is imported.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.