    Correlated Fits and Theory Uncertainties

    Observables can move together through shared couplings or calibration. Ignoring their correlations changes a fit. Our exact example determines one parameter combination sharply while leaving another broad, despite small residuals.

    Preparation: Electroweak input schemes and elementary matrix inversion. Every numerical datum on this page is synthetic and dimensionless. We use a linear response model for the three synthetic observables.

    A complete three-observable example

    Let the predicted residuals of three observables be Aθ+bηA\theta+b\eta, where θ=(θ1,θ2)T\theta=(\theta_1,\theta_2)^T are the parameters of interest and η\eta is a shared calibration offset. Specify the synthetic data and the response:

    y=(1.020.980.20),A=(111.050.951−1),b=(0.100.100).y=\begin{pmatrix}1.02\\0.98\\0.20\end{pmatrix},\qquad A=\begin{pmatrix}1&1\\1.05&0.95\\1&-1\end{pmatrix},\qquad b=\begin{pmatrix}0.10\\0.10\\0\end{pmatrix}.

    The experimental covariance at fixed calibration is

    V=(0.0100.00600.0060.0100001).V=\begin{pmatrix}0.010&0.006&0\\0.006&0.010&0\\0&0&1\end{pmatrix}.

    Its eigenvalues are 0.004,0.016,10.004,0.016,1, all positive. The first two measurement errors have correlation 0.60.6. An independent auxiliary calibration measurement is aaux=0a_{\rm aux}=0 with standard deviation one, conditional mean η\eta. The likelihood is therefore proportional to e−χ2/2e^{-\chi^2/2}, with

    χ2(θ,η)=(y−Aθ−bη)TV−1(y−Aθ−bη)+(aaux−η)2.\chi^2(\theta,\eta)=(y-A\theta-b\eta)^TV^{-1}(y-A\theta-b\eta)+(a_{\rm aux}-\eta)^2.

    The last term is one auxiliary measurement, not an extra error already contained in VV. This explicit construction follows the nuisance-likelihood logic of Cowan et al., §2, Eqs. (5)–(8), while all matrices here are newly chosen examples.

    Eliminate the nuisance by completing the square

    For the displayed aaux=0a_{\rm aux}=0, put r=y−Aθr=y-A\theta. Differentiation with respect to η\eta gives

    η^θ=bTV−1r1+bTV−1b.\widehat\eta_\theta=\frac{b^TV^{-1}r}{1+b^TV^{-1}b}.

    Substitution yields

    χprof2(θ)=rTWr,W=V−1−V−1bbTV−11+bTV−1b=(V+bbT)−1.\chi^2_{\rm prof}(\theta)=r^TWr,\qquad W=V^{-1}-\frac{V^{-1}bb^TV^{-1}}{1+b^TV^{-1}b}=(V+bb^T)^{-1}.

    The final equality is verified by multiplying by V+bbTV+bb^T. Thus an equivalent fixed covariance is

    C=V+bbT=(0.0200.01600.0160.0200001).C=V+bb^T=\begin{pmatrix}0.020&0.016&0\\0.016&0.020&0\\0&0&1\end{pmatrix}.

    One must use either this profiled covariance or the explicit nuisance with its auxiliary term. Using both counts the calibration uncertainty twice. In a probabilistic treatment with a Gaussian measure for the nuisance, integration gives the same θ\theta dependence here because its curvature is constant. With parameter-dependent responses or covariance, that determinant factor can depend on θ\theta, and profiling and marginalization need not agree.

    Solve the two-parameter fit

    The normal equations are obtained by differentiating rTWrr^TWr:

    Fθ^=ATWy,F=ATWA,Cov⁡(θ^)=F−1.F\widehat\theta=A^TWy,\qquad F=A^TWA,\qquad \operatorname{Cov}(\widehat\theta)=F^{-1}.

    The covariance statement refers to repetitions of both the data and auxiliary measurement under the declared Gaussian model. For a nonzero repeated auxiliary value, the equivalent residual data are y−baauxy-ba_{\rm aux}, with covariance V+bbTV+bb^T.

    An exact calculation is especially simple with u=θ1+θ2u=\theta_1+\theta_2 and v=θ1−θ2v=\theta_1-\theta_2. Define yˉ=(y1+y2)/2=1\bar y=(y_1+y_2)/2=1 and d=y2−y1=−0.04d=y_2-y_1=-0.04. The profiled sum and difference errors are independent and have variances 0.0180.018 and 0.0080.008, respectively. The objective becomes

    χprof2=(yˉ−u−0.025v)20.018+(d−0.05v)20.008+(y3−v)2.\chi^2_{\rm prof}=\frac{(\bar y-u-0.025v)^2}{0.018}+\frac{(d-0.05v)^2}{0.008}+(y_3-v)^2.

    Minimizing over uu removes the first residual. The remaining equation is

    v^=(0.05/0.008)d+y30.052/0.008+1=−4105,u^=1−0.025v^=10511050.\widehat v=\frac{(0.05/0.008)d+y_3}{0.05^2/0.008+1}=-\frac4{105},\qquad \widehat u=1-0.025\widehat v=\frac{1051}{1050}.

    Transforming back gives

    θ^=(0.481428570.51952381),χmin⁡2=521=0.23809524,\widehat\theta=\begin{pmatrix}0.48142857\\0.51952381\end{pmatrix},\qquad \chi^2_{\min}=\frac5{21}=0.23809524, F−1=(0.18557143−0.18585714−0.185857140.20461905).F^{-1}=\begin{pmatrix}0.18557143&-0.18585714\\-0.18585714&0.20461905\end{pmatrix}.

    The fitted nuisance is zero because its response is exactly along the freely fitted common-mean direction: b=A(0.05,0.05)Tb=A(0.05,0.05)^T. Nevertheless its uncertainty broadens that direction. A zero nuisance pull does not mean the nuisance can be deleted.

    Find the weak direction

    The eigenvalues of FF are approximately 2.623322.62332 and 111.18223111.18223. The weak unit direction in parameter space is

    eweak=(0.688776−0.724974),σweak=12.62332=0.61741.e_{\rm weak}=\begin{pmatrix}0.688776\\-0.724974\end{pmatrix},\qquad \sigma_{\rm weak}=\frac1{\sqrt{2.62332}}=0.61741.

    The strong direction is nearly the sum of the two parameters and has standard deviation 0.094840.09484. The first two observations constrain that sum well but distinguish the difference only through the small coefficient 0.050.05. The third observation measures the difference directly, with a much larger error. Small residuals therefore coexist with a broad family of allowed parameters.

    Long tilted ellipses in the two parameter coordinates show a weak difference direction; including the shared calibration broadens the ellipse across the strong direction.

    Contours of Δχ2=2.30\Delta\chi^2=2.30 for the synthetic model, with the calibration profiled (solid) and fixed (dashed). The arrow marks the weak direction of the profiled fit. This is a two-parameter Gaussian contour, not two independent one-standard-deviation intervals or an electroweak data result.

    The companion compares the analytic result with an augmented least-squares solution using the original nuisance and a Cholesky whitening of VV. It also demonstrates that deleting experimental correlations changes the fitted parameters.

    What an uncertainty means

    An uncertain physical input xx with covariance CxC_x induces JCxJTJ C_xJ^T, where Jia=∂μi/∂xaJ_{ia}=\partial\mu_i/\partial x_a. That is a parametric uncertainty. An experimental calibration can instead be constrained by an auxiliary measurement as above. A missing perturbative order is neither of these automatically: representing it by a Gaussian nuisance is an additional statistical model, requiring a scale and correlation prescription. A scale-variation envelope alone does not supply a repeated-sampling distribution.

    In this exact linear Gaussian model there are four independent whitened data components (three observables plus one auxiliary result) and three fitted parameters. Thus the minimized statistic has one chi-square degree of freedom under the model. Boundaries, estimated or parameter-dependent covariances, nonlinearity, or a data-selected subset can invalidate that simple count. The regular asymptotic likelihood conditions are discussed in Cowan et al., §3.1.

    A good fit establishes compatibility with this specified family; it does not establish uniqueness of the underlying theory. A new observable with a response along the weak direction can discriminate models that the original set cannot.

    Exercises

    1. Remove the auxiliary calibration measurement, retaining the three observables and allowing η\eta to vary freely. Show the exact flat direction. Does the third observable remove it?
    Solution

    Because b=A(0.05,0.05)Tb=A(0.05,0.05)^T, the transformation

    θ⟼θ+t(0.050.05),η⟼η−t\theta\longmapsto\theta+t\begin{pmatrix}0.05\\0.05\end{pmatrix},\qquad \eta\longmapsto\eta-t

    leaves Aθ+bηA\theta+b\eta unchanged for every tt. The third observable depends on θ1−θ2\theta_1-\theta_2 and is also unchanged. Thus the full parameter Hessian is singular without the auxiliary constraint. This exact common-mean/calibration degeneracy differs from the weak but nonzero difference-direction eigenvalue of the constrained fit.

    1. An independent measurement has unit response along eweake_{\rm weak} and standard deviation 0.200.20. Find the updated weak-direction variance and compare with an equally precise strong-direction measurement.
    Solution

    The new information is eweakeweakT/0.202e_{\rm weak}e_{\rm weak}^T/0.20^2. It adds 2525 to the weak eigenvalue without changing the orthogonal eigenvalue. Hence

    Var⁡weak,new=12.62332+25=0.0362013,σweak,new=0.190266.\operatorname{Var}_{\rm weak,new}=\frac1{2.62332+25}=0.0362013,\qquad \sigma_{\rm weak,new}=0.190266.

    Along the strong direction, the measurement changes 111.18223111.18223 to 136.18223136.18223 but leaves the largest uncertainty unchanged. This assumes independence and a known response; shared calibration can reduce the gain.

    Summary

    A profiled covariance identifies the weak direction. Calibration, physical-input and missing-order uncertainties need distinct models; individual pulls do not specify them.

    References

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.