- Home
- Library
- Nonperturbative Quantum Field Theory
- From a Functional Identity to a Bound-State Observable
- Renormalized Propagator Equations
Renormalized Propagator Equations
A propagator calculated at two subtraction points should describe the same system after its parameters and field normalization are matched. Keeping the same numerical “renormalized mass” at both points usually changes the system instead. We will carry out the matching in a scalar integral equation whose finite-cutoff realization is a positive Gaussian theory, then separate subtraction-point invariance from cutoff convergence.
Preparation: Closure of a functional hierarchy, Gaussian integration and Euclidean covariance. We use four-dimensional Euclidean momentum and write . The model below is exactly soluble for its specified mixing kernel; it is not a self-consistent truncation of an interacting scalar theory.
A propagator equation with a positive microscopic realization
Start with a real scalar and finitely many real scalar fields , all with canonical kinetic terms. Their quadratic action is
Here , , and the real mixing coefficient has mass dimension two. Strip the momentum-conserving delta function from the covariance. Completing each Gaussian square then gives
The minus sign follows from eliminating a coupled Gaussian variable. It is not selected by a convention for a diagram. Equivalently, multiplying the full inverse covariance matrix by its inverse produces this Dyson equation.
A continuum of fields is specified by a positive mixing measure. Choose
The quantities have mass dimension two. The square-root threshold and its location are model inputs. This shape resembles four-dimensional two-body phase space, but the present construction consists of linearly mixed Gaussian fields; it does not derive an interacting two-particle channel. Scalar-tower mixing and inversion of the quadratic matrix are used in van der Bij and Puliçe, §2, Eqs. (4)–(9) (PDF). Their mass distribution and Higgs interactions differ from the explicitly chosen measure here.
Define the dimensionless regulated bath integral
It has a logarithmic mass divergence. The derivative has a finite infinite-cutoff limit, so this Gaussian example needs no divergent wavefunction counterterm.
Fix the system before changing the subtraction point
Choose a physical static normalization and a canonical ultraviolet normalization:
The second condition follows from the canonical kinetic term; is the inverse zero-momentum susceptibility of this normalized field. It is not its pole mass squared. Hold fixed as the regulator changes. The required bare mass is
This also proves positivity of the finite Gaussian model. Its zero-momentum mass matrix has positive bath block and Schur complement . Both are positive, so the full mass matrix is positive. The same construction can be approached through positive quadrature measures as the number of bath fields grows.
For large , the subtracted integrand is . Therefore the covariance has a finite cutoff limit at fixed , with a leading inverse-kernel error of order . Raising the cutoff without retuning would instead change the static susceptibility and eventually violate the assumed positive mass matrix.
Now choose a spacelike subtraction point . Define
Then and . The corresponding field is , so in the inherited notation one has . The renormalized equation reads
The bracket and its first derivative vanish at the subtraction point. Its separately convergent integral is
The identity makes numerical cancellation avoidable. It also shows why changing requires changing all of . In this exact Gaussian model the change in is due to finite field normalization; it is not an interacting vertex beta function.
The distinction between regulator, subtraction point, bare mass and propagator dressing is central to the renormalized quark equation in Maris and Roberts, §2, Eqs. (2.1)–(2.5) (PDF). Our equation supplies a small example where their separation can be tested without the additional gauge or vertex truncation issues.
Two subtraction points, one covariance
Measure masses in one fixed reference unit and choose
At , the two subtraction prescriptions give
Neither mass parameter equals the pole mass squared. Nor should the two agree before restoring a common field normalization. The matched comparison is
The companion evaluates the original once-subtracted equation and the twice-subtracted equation separately on . The largest inverse-kernel disagreement in the selected cutoffs is below . That tests the matching algebra and its numerical implementation. It does not test the cutoff limit, which is a different comparison:
| Difference from infinite cutoff | |||
|---|---|---|---|
The logarithmically growing bare mass accompanies a convergent covariance. Doubling reduces the remaining error approximately fourfold, as the large- tail predicts. For this chosen measure the infinite-cutoff reference is a direct convergent integral, not an extrapolated fit.
Diagonalize the fields instead of the scalar equation
A different calculation discretizes the mass measure and diagonalizes the full real symmetric matrix
If and the eigenvectors are orthonormal, the distinguished field has
This constructs positive masses and weights without using the analytic pole or cut formula. At fixed , increasing the bath quadrature from to nodes reduces the lowest-mass-squared errors from to , and . The final maximum Euclidean covariance disagreement is . These are discretization errors at fixed cutoff, not errors relative to the infinite-cutoff theory. All finite matrix weights, including any level near or above the artificial upper bath edge, are retained.
Here the physical inputs fix the inverse static susceptibility and the ultraviolet field normalization. The value and slope used at a subtraction point are related to those same inputs, while a pole residue is determined at the pole. A bound-state current normalized by the pole residue needs the two-body kernel and its symmetry-compatible current as well. Moving the subtraction point is one consistency test on the input to that calculation.
What a matching test can and cannot establish
Subtraction-point independence is meaningful only after specifying what is held fixed. Here the answer is the normalized field's static response, the bath coupling and its threshold measure. A numerical solution with an unchanged mass parameter at a new subtraction point need not describe the same input. Conversely, exact cancellation of a subtraction point does not establish that an ansatz describes a desired interacting theory.
In the chapter's regulated chiral model, the cutoff is part of the effective interaction definition. Its finite-cutoff predictions must not be assigned the continuum limit demonstrated for this different Gaussian model. In a genuine self-consistent field theory, the vertex and interaction parameters also have to be renormalized consistently with the propagator.
Summary
A mass subtraction removes the bath's logarithmic divergence at fixed physical input. Momentum subtraction additionally fixes a finite field normalization, so comparing two propagators requires undoing that normalization. Separate matrix-size, cutoff and subtraction-point checks answer different questions. The same covariance will next be continued to its pole and continuum spectrum.
Exercises
1. Keep the numbers but move the subtraction point
Suppose a calculation imposes the same numerical and unit inverse slope at two distinct subtraction points, while keeping the same numerical . Show why the resulting inverse propagators generally differ even before numerical errors.
Solution
Define
The two equations are . Their difference is
This is an affine function of , with a nonzero slope unless . In the positive bath model for spacelike , so different subtraction points have different slopes. The two numerical mass conditions therefore specify different static responses and field normalizations. Matching requires the finite transformations derived above; the algebra does not permit deleting these terms merely because the bracket is ultraviolet finite.
2. Change the ultraviolet bath density
Replace the asymptotically constant by a positive weight behaving as at large , with fixed normalization scales understood. Determine when zero, one or two subtractions make the bath integral convergent. Can a finite two-subtracted inverse kernel alone establish a positive canonical ultraviolet completion?
Solution
The unsubtracted integrand behaves as , so it is integrable at infinity for . One mass subtraction replaces it by a constant times , requiring . Subtracting the slope as well leaves , requiring . The endpoints are logarithmically divergent.
These power counts concern a fixed external momentum. They do not prove that a positive bare kinetic term can be maintained when the regulator is removed. For example, if a divergent positive contribution to the inverse slope must be canceled while fixing a finite canonical normalization, the bare kinetic coefficient can be driven negative. One must check the full regulated quadratic form and its spectral limit, rather than infer a Hilbert-space interpretation from a formally finite subtraction formula. The original constant-weight model avoids this difficulty because its slope integral converges.
References
- P. Maris and C. D. Roberts, Dyson–Schwinger Equations: A Tool for Hadron Physics, International Journal of Modern Physics E 12 (2003), 297–365, arXiv:nucl-th/0301049v1. Section 2, Eqs. (2.1)–(2.5), fixes the regulator and renormalization-point roles for the quark propagator.
- J. J. van der Bij and B. Puliçe, New Spectra in the HEIDI Higgs Models, Nuclear Physics B 853 (2011), 49–64, arXiv:1104.2062v1. Section 2, Eqs. (4)–(9), constructs the scalar mixing matrix and its continuum propagator. The bath weight and subtraction conditions on this page are defined separately.
The source and selected refinements are in examples/nonperturbative/functional-equations/propagators/.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.