- Home
- Library
- Statistical Field Theory
- Critical Scaling through Observable Response
- Scaling Functions and Universal Amplitude Ratios
Scaling Functions and Universal Amplitude Ratios
Two magnets can have the same critical exponents and very different magnetization curves in laboratory units. Scaling compares them after a fixed normalization of the thermal field, ordering field and observable. An amplitude ratio is useful when those nonuniversal factors cancel for a precisely defined pair of measurements.
Preparation: The normalized mean-field potential, the response paths and stable minima of a scalar Landau potential.
Fix the axes before comparing curves
Write an equation of state as , where . A thermal scaling field may itself be , so its normalization must also be fixed. The constants are properties of the system and the observable; they cannot be refitted separately at every data point. After choosing, for example, one coexistence amplitude and one critical-isotherm amplitude, the remaining shape is a test.
The following calculation uses homogeneous mean-field theory, with physical potential
It supplies a complete example of normalization, not a numerical approximation to a three-dimensional Ising scaling function. Set , and
The stable branch minimizes . For it is unique. For it is the positive root with ; at take its limit . Other stationary roots can be metastable or unstable and do not define the equilibrium scaling function. The negative-source branch follows by reflection. At coexistence the equilibrium function jumps between the two selected phases.
Different microscopic parameters, one normalized curve
Compare two illustrative systems in the same declared units: I has and II has . Their metrics are and . At , choose the normalized sources . Direct solution of the cubic gives:
| Stable above | in I | in II | ||
|---|---|---|---|---|
These numbers come from minimizing two different physical potentials, then using the fixed metrics. Comparing at the same physical source would compare different values. Below the transition, the same construction gives at and at .
Susceptibility and its amplitude ratio
Differentiate the stationarity equation at fixed temperature:
Above the transition, gives . Below it, the selected phase has , giving . Therefore
The parameter drops out within each susceptibility amplitude, while cancels only in the ratio. This concerns the scalar longitudinal response with the same physical source on both sides. At finite volume and exactly zero source, fluctuations between both ordered minima produce an additional contribution proportional to volume; that is not .
More generally, if and the same analytic thermal coordinate is replaced by , then for . If the order parameter is renamed , conjugacy requires , so . Both changes cancel in . A ratio of amplitudes belonging to different observable definitions need not cancel anything.
A second ratio and a background test
Add the same gradient term on both sides. Gaussian fluctuations about the scalar minimum give
Here exponential and second-moment lengths agree because the propagator has a single quadratic pole. For an interacting model they are different definitions with different ratios. In a continuous-symmetry ordered phase, a transverse massless mode is not this scalar longitudinal length.
Suppose the measured susceptibilities are . The ratio at equal is . A finite-distance departure from two can therefore reflect regular backgrounds rather than a different asymptotic amplitude ratio. Data collapse must test corrections and a stable limiting window as well as the axis normalization.
Exercises
1. A ratio involving the critical isotherm. In the same model define and for positive source. Evaluate and check its invariance under , .
Solution
The amplitudes are , and , hence . Under the conjugate rescaling, , and for . Numerator and denominator both acquire . The result is invariant, whereas each amplitude separately changes.
2. Quantify a misleading finite-distance ratio. Take , and in the susceptibility-background example. Evaluate the ratio at and and find its first correction near zero.
Solution
Here and . The exact illustrative ratio is , giving and . Its expansion is . The unequal backgrounds are compatible with the limiting ratio two.
Summary
A universal scaling function has a definite normalization convention. Susceptibility ratios compare two limits of the same observable and can remove source and temperature metrics. The exact mean-field ratio two is a benchmark; interaction corrections and the definition of the measured response must be handled before comparing it with a real system.
References
- A. Pelissetto and E. Vicari, Critical Phenomena and Renormalization-Group Theory, v6, Table 2, §1.3 following Eq. (1.43), and §1.5.2, Eqs. (1.62)–(1.69): observable-specific ratios and normalization of scaling functions. Our quartic uses and our susceptibility is a physical source derivative.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.