Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Scaling Functions and Universal Amplitude Ratios

    Two magnets can have the same critical exponents and very different magnetization curves in laboratory units. Scaling compares them after a fixed normalization of the thermal field, ordering field and observable. An amplitude ratio is useful when those nonuniversal factors cancel for a precisely defined pair of measurements.

    Preparation: The normalized mean-field potential, the response paths and stable minima of a scalar Landau potential.

    Fix the axes before comparing curves

    Write an equation of state as m=m0∣t∣βM±(y)m=m_0|t|^\beta\mathcal M_\pm(y), where y=hphys/(h0∣t∣βδiso)y=h_{\rm phys}/(h_0|t|^{\beta\delta_{\rm iso}}). A thermal scaling field may itself be ctt+O(t2,hphys2)c_t t+O(t^2,h_{\rm phys}^2), so its normalization must also be fixed. The constants are properties of the system and the observable; they cannot be refitted separately at every data point. After choosing, for example, one coexistence amplitude and one critical-isotherm amplitude, the remaining shape is a test.

    The following calculation uses homogeneous mean-field theory, with physical potential

    v(m;t,hphys)=at2m2+u4m4−hphysm,a,u>0.v(m;t,h_{\rm phys})=\frac{at}{2}m^2+\frac u4m^4-h_{\rm phys}m,\qquad a,u>0.

    It supplies a complete example of normalization, not a numerical approximation to a three-dimensional Ising scaling function. Set m0=a/um_0=\sqrt{a/u}, h0=am0h_0=a m_0 and

    x=mm0∣t∣1/2,y=hphysh0∣t∣3/2,y=sgn⁡(t)x+x3.x=\frac{m}{m_0|t|^{1/2}},\qquad y=\frac{h_{\rm phys}}{h_0|t|^{3/2}},\qquad y=\operatorname{sgn}(t)x+x^3.

    The stable branch minimizes sgn⁡(t)x2/2+x4/4−yx\operatorname{sgn}(t)x^2/2+x^4/4-yx. For t>0t>0 it is unique. For t<0,y>0t<0,y>0 it is the positive root with x>1x>1; at y=0y=0 take its limit x=1x=1. Other stationary roots can be metastable or unstable and do not define the equilibrium scaling function. The negative-source branch follows by reflection. At coexistence the equilibrium function jumps between the two selected phases.

    Different microscopic parameters, one normalized curve

    Compare two illustrative systems in the same declared units: I has (a,u)=(2,8)(a,u)=(2,8) and II has (a,u)=(8,2)(a,u)=(8,2). Their metrics are (m0,h0)=(1/2,1)(m_0,h_0)=(1/2,1) and (2,16)(2,16). At t=0.04t=0.04, choose the normalized sources y=0,1,2y=0,1,2. Direct solution of the cubic gives:

    yyStable xx above TcT_cmm in Imm in II(hphys,I,hphys,II)(h_{\rm phys,I},h_{\rm phys,II})
    00000000(0,0)(0,0)
    110.6823278040.6823278040.06823278040.06823278040.2729311220.272931122(0.008,0.128)(0.008,0.128)
    22110.10.10.40.4(0.016,0.256)(0.016,0.256)

    These numbers come from minimizing two different physical potentials, then using the fixed metrics. Comparing at the same physical source would compare different yy values. Below the transition, the same construction gives x=1x=1 at y=0+y=0^+ and x=1.324717957x=1.324717957 at y=1y=1.

    Susceptibility and its amplitude ratio

    Differentiate the stationarity equation at fixed temperature:

    χ=∂m∂hphys=1at+3um2=1a∣t∣1sgn⁡(t)+3x2.\chi=\frac{\partial m}{\partial h_{\rm phys}}=\frac1{at+3um^2}=\frac1{a|t|}\frac1{\operatorname{sgn}(t)+3x^2}.

    Above the transition, m=0m=0 gives C+=1/aC_+=1/a. Below it, the selected phase has m2=a∣t∣/um^2=a|t|/u, giving C−=1/(2a)C_-=1/(2a). Therefore

    C+C−=2.\frac{C_+}{C_-}=2.

    The parameter uu drops out within each susceptibility amplitude, while aa cancels only in the ratio. This concerns the scalar longitudinal response with the same physical source on both sides. At finite volume and exactly zero source, fluctuations between both ordered minima produce an additional contribution proportional to volume; that is not C−C_-.

    More generally, if χ=C±∣t∣−γ\chi=C_\pm|t|^{-\gamma} and the same analytic thermal coordinate is replaced by t′=ct+O(t2)t'=ct+O(t^2), then C±′=cγC±C'_\pm=c^\gamma C_\pm for c>0c>0. If the order parameter is renamed m′=smm'=s m, conjugacy requires hphys′=hphys/sh'_{\rm phys}=h_{\rm phys}/s, so χ′=s2χ\chi'=s^2\chi. Both changes cancel in C+/C−C_+/C_-. A ratio of amplitudes belonging to different observable definitions need not cancel anything.

    A second ratio and a background test

    Add the same gradient term κ(∇m)2/2\kappa(\nabla m)^2/2 on both sides. Gaussian fluctuations about the scalar minimum give

    ξ+=κa t−1/2,ξ−=κ2a ∣t∣−1/2,ξ+,0ξ−,0=2.\xi_+=\sqrt{\frac\kappa a}\,t^{-1/2},\qquad \xi_-=\sqrt{\frac\kappa{2a}}\,|t|^{-1/2},\qquad \frac{\xi_{+,0}}{\xi_{-,0}}=\sqrt2.

    Here exponential and second-moment lengths agree because the propagator has a single quadratic pole. For an interacting model they are different definitions with different ratios. In a continuous-symmetry ordered phase, a transverse massless mode is not this scalar longitudinal length.

    Suppose the measured susceptibilities are χ±=C±∣t∣−1+B±+⋯\chi_\pm=C_\pm|t|^{-1}+B_\pm+\cdots. The ratio at equal ∣t∣|t| is 2[1+(B+/C+−B−/C−)∣t∣+⋯ ]2[1+(B_+/C_+-B_-/C_-)|t|+\cdots]. A finite-distance departure from two can therefore reflect regular backgrounds rather than a different asymptotic amplitude ratio. Data collapse must test corrections and a stable limiting window as well as the axis normalization.

    Exercises

    1. A ratio involving the critical isotherm. In the same model define m(t,0+)=B(−t)1/2m(t,0^+)=B(-t)^{1/2} and m(0,hphys)=Bchphys1/3m(0,h_{\rm phys})=B_c h_{\rm phys}^{1/3} for positive source. Evaluate Rχ=C+B2/Bc3R_\chi=C_+B^2/B_c^3 and check its invariance under m′=smm'=s m, hphys′=hphys/sh'_{\rm phys}=h_{\rm phys}/s.

    Solution

    The amplitudes are B=a/uB=\sqrt{a/u}, Bc=u−1/3B_c=u^{-1/3} and C+=1/aC_+=1/a, hence Rχ=1R_\chi=1. Under the conjugate rescaling, B′=sBB'=sB, C+′=s2C+C'_+=s^2C_+ and Bc′=s4/3BcB'_c=s^{4/3}B_c for s>0s>0. Numerator and denominator both acquire s4s^4. The result is invariant, whereas each amplitude separately changes.

    2. Quantify a misleading finite-distance ratio. Take a=2a=2, B+=3B_+=3 and B−=1B_-=1 in the susceptibility-background example. Evaluate the ratio at ∣t∣=0.1|t|=0.1 and 0.010.01 and find its first correction near zero.

    Solution

    Here C+=1/2C_+=1/2 and C−=1/4C_-=1/4. The exact illustrative ratio is (1/2+3∣t∣)/(1/4+∣t∣)(1/2+3|t|)/(1/4+|t|), giving 16/7≈2.28571416/7\approx2.285714 and 53/26≈2.03846253/26\approx2.038462. Its expansion is 2+4∣t∣+O(t2)2+4|t|+O(t^2). The unequal backgrounds are compatible with the limiting ratio two.

    Summary

    A universal scaling function has a definite normalization convention. Susceptibility ratios compare two limits of the same observable and can remove source and temperature metrics. The exact mean-field ratio two is a benchmark; interaction corrections and the definition of the measured response must be handled before comparing it with a real system.

    References

    • A. Pelissetto and E. Vicari, Critical Phenomena and Renormalization-Group Theory, v6, Table 2, §1.3 following Eq. (1.43), and §1.5.2, Eqs. (1.62)–(1.69): observable-specific ratios and normalization of scaling functions. Our quartic uses u/4u/4 and our susceptibility is a physical source derivative.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.