- Home
- Library
- Statistical Field Theory
- From Block Spins to Critical Exponents
- Anisotropy and Fixed-Point Stability
Anisotropy and Fixed-Point Stability
A symmetric minimum does not by itself imply a symmetric critical point. A crystal can have only cubic symmetry while its long-distance fluctuations approach an O(N)-symmetric theory—or a small anisotropy can grow until that description fails. The distinction is determined by an RG eigenvalue.
Preparation: O(N) shell integration, thermal scaling operators and the Landau analysis of several components. We work at the thermally tuned critical surface in spatial , with , and use increasing length-scale RG time .
Specify the anisotropic interaction
For real fields with canonical gradient term, take
Repeated indices in the O(N) term are summed. The second term preserves permutations and independent sign reversals of components, but generally not continuous rotations. For the two quartics coincide, so a two-coupling stability analysis would be redundant.
Writing with gives . Consequently the quartic is strictly positive in every direction precisely when
For , equal component magnitudes minimize the angular quartic; for , an axis minimizes it. These tree-level statements identify preferred directions. They do not determine whether anisotropy survives at the critical point.
Contract the one-loop tensors
Use the dimensionless four-leg vertex
where is one when all four indices are equal and zero otherwise. The connected second cumulant has the same negative sign and factor as the isotropic calculation. Its three bubble channels contract as
The pure contribution was calculated on the shell page. For the mixed term, one channel contains . Summing its three index arrangements produces before the factors and . The pure contraction gives before . Hence
Rescaling supplies the engineering term, so on the critical surface through one-loop order,
Terms cubic in couplings have been omitted. Setting the shell mass to zero in these coefficients is consistent at this order because its critical value is already first order in . The singlet tadpole is shifted as well: , giving the additive mass-flow term . The critical temperature must therefore be retuned when the anisotropy changes.
These coefficients have been checked by constructing the complete rank-four arrays and summing their internal indices for several integer and independent pairs . The check does not infer a tensor identity solely from an already-reduced two-coupling formula.
Test the isotropic fixed point
At and , the quartic stability matrix is
Thus the isotropic radial correction has eigenvalue , while the cubic perturbation has
Positive means growth toward long distances. To this order, anisotropy is irrelevant for and relevant for . The off-diagonal entry shows why varying while holding fixed is not a scaling eigenvector. For the cubic eigenmode one also shifts by at linear order.
For example gives , a very slow decay, whereas gives . For a relevant perturbation with initial scaling coordinate , its order-one crossover length obeys , up to the normalization of that coordinate. A small positive eigenvalue can therefore hide anisotropy over a large range of lengths. This estimate holds only while the flow remains in the linear neighborhood.
Irrelevance at the critical point also does not mean that a microscopic anisotropy cannot select an orientation in the ordered phase. The limit of vanishing anisotropy can be singular there; that question is distinct from critical-point stability.
Locate the other fixed points
Solving the two beta functions gives the Gaussian, decoupled Ising and cubic fixed points, in addition to O(N):
At the cubic point the two quartic eigenvalues are
It is attractive in both quartic directions for at this order and a saddle for . Its quartic satisfies both positivity inequalities for . At the decoupled Ising point, the cross-component coupling has eigenvalue , while the diagonal quartic has eigenvalue . Thus the decoupled point is not generically stable against coupling the components.
This counts quartic directions within the cubic-symmetric subspace, not every possible relevant perturbation. A generic magnetic source or unequal quadratic masses needs additional tuning. The singlet thermal direction remains relevant even at a quartically attractive fixed point.
At the cubic and isotropic points meet and the displayed anisotropy eigenvalue vanishes. Higher orders decide the marginal direction; the one-loop result does not. More generally, setting does not reliably determine a small stability eigenvalue. The higher-order analyses reviewed by Pelissetto and Vicari, §11.3 place the three-dimensional exchange of stability below , illustrating the failure of the naive one-loop extrapolation. Their historical numerical estimates are not used here as a current precision determination.
Summary
Cubic anisotropy supplies a concrete test of emergent symmetry. Its tensor contractions produce a coupled flow, and the linearized eigenvalue decides whether the isotropic critical point attracts or repels that perturbation. The conclusion is controlled near four dimensions and only within the stated symmetry and tuning conditions.
Exercises
1. Rotate the two-component theory
For , set and . Find the transformed quartic couplings and relate the decoupled Ising and cubic fixed points.
Solution
The norm is unchanged and direct expansion gives
Therefore and . The point maps to , exactly the cubic point. The orthogonal rotation preserves their stability eigenvalues and : this is one decoupled theory in different axes, not distinct universality classes. Applying it twice restores the couplings.
2. Allow unequal masses
At the O(N) fixed point, can irrelevance of the quartic cubic perturbation remove the need to tune a traceless quadratic perturbation? Use the thermal-operator calculation to answer.
Solution
For a symmetric mass matrix , the tadpole contraction is . A traceless part therefore has length-flow eigenvalue
for sufficiently small positive . It remains relevant even when . Full cubic symmetry enforces a singlet mass; without it, independent mass splittings also require tuning. Quartic stability supplies no such symmetry.
References
- A. Pelissetto and E. Vicari, Critical Phenomena and Renormalization-Group Theory, v6, §11.3, Eqs. (11.10)–(11.11) and Table 33, printed pp. 102–105: cubic Hamiltonian, fixed points, two-component rotation and first-order extrapolation limits; our coupling normalization and one-loop contractions are derived above.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.