- Home
- Library
- Statistical Field Theory
- Percolation, Random Clusters and Loop Models
- Loop Models and Coulomb-Gas Methods
Loop Models and Coulomb-Gas Methods
A loop fugacity can become a background charge in a height field. The relation is meaningful only after choosing the microscopic loops, their boundaries and a critical branch. We use the medial boundaries of Fortuin–Kasteleyn clusters on the square lattice and derive a two-leg scaling dimension within their dense critical Coulomb-gas description. These heights are not the angle of an XY spin, and their defects are not automatically XY vortices.
Preparation: The random-cluster expansion and logarithmic Gaussian correlations. Gaussian stress-tensor and cylinder facts needed below are introduced explicitly.
A boundary crossing in an open sample can be recorded by tracing occupied clusters. Here we instead follow the interfaces between primal and dual clusters.
A specified medial-loop construction
Embed a connected graph in the plane. For an occupied subset , draw its primal clusters and the dual clusters made from the complementary edges. The interface between them runs on the medial lattice. At each original edge there are two possible noncrossing pairings of the four medial half-edges, determined by whether that edge is occupied. Complete the boundary using the exterior dual face, so all interfaces are closed. They separate primal from dual clusters; no crossing or extra intersection weight is introduced.
Let count primal components and dual components, including the exterior. Euler's formula for a planar spanning subgraph gives . The number of interface loops is , hence
One way to see the loop count is to thicken each occupied cluster to a small planar neighborhood. A tree component has one boundary; each independent cycle adds a further boundary. Summing over components gives the same formula, including isolated vertices.
At the self-dual value , both local medial pairings have equal weight and each closed loop has fugacity . We restrict the following continuum description to the ferromagnetic critical branch , with the endpoint admitting marginal logarithmic corrections. This branch identification is additional critical-model information, not a consequence of Euler's formula alone. The worked case is .
Orientation weights and a height
Choose so that . Orient every loop and give a turn through signed angle the factor . A simple contractible loop turns by . Summing its two orientations therefore gives
On the square medial lattice a quarter-turn has phase ; on a honeycomb realization a turn through would have . The total turning angle, rather than the number of vertices, fixes the fugacity.
Assign a height to regions separated by oriented loops, increasing by on crossing a loop in a chosen oriented-normal direction. Fix the exterior height to zero. Noncrossing closed loops make this assignment consistent on a simply connected domain. Height offsets and allowed defects are part of the boundary data; summing an unrestricted continuous zero mode would not reproduce the original fixed-boundary sum.
A loop winding around a cylinder has zero net turn, so local turn weights alone would give it weight two. Introduce a seam along the cylinder that multiplies an oriented winding crossing by . Products along the seam telescope into endpoint vertex factors with charges and . Omitting them changes the winding-loop weights and the finite-size spectrum. A torus requires compatible winding-sector prescriptions in both cycles; the following cylinder calculation is not a formula for every torus partition function.
The Gaussian continuum input and its charges
Assume the tuned loop model is in a rough, scale-invariant height regime. Locality and height-shift symmetry then motivate the leading bulk gradient action
The microscopic-to-continuum step is an effective-field-theory identification, not an exact integration of every lattice height. Higher-gradient terms are irrelevant at the Gaussian point; periodic locking operators and the loop background charge must still be included. The covariance follows by inverting .
On a curved surface a convenient background-charge convention is
Here is the metric; in is the scalar stiffness. The boundary curvature term includes corner angles. Gauss–Bonnet gives for a constant height, so vertex insertions require total charge when the zero mode is integrated in this representation. In particular the sphere requires . On the cylinder, the seam endpoint charges implement the required winding weighting. The complex orientation factors are a representation of the real loop sum, not an additional positive probability measure on arbitrary charged heights.
The holomorphic stress tensor and its local contractions are
To derive the dimension, use . The quadratic and improvement terms give holomorphic weight ; the scalar dimension is twice this. Double contraction of the two quadratic stress tensors gives , while the two improvements give . Since the identity coefficient in is , the displayed central charge follows. Boundary neutrality still determines which local charge insertions actually define a nonzero correlator.
The discrete heights allow screening fields with charge of magnitude two. On the selected dense branch choose the marginal screening charge . Its dimension must be two, giving
Marginality and the choice of screening branch are part of the Coulomb-gas solution. They cannot be inferred from shift symmetry alone. The alternative dilute branch has and describes different critical loop ensembles; one must not switch branches while keeping an observable identification unchanged.
A two-leg dimension with its vacuum subtraction
In a boundary sector that permits them, consider nonintersecting loop strands constrained to run along a long cylinder of circumference and length . Orient those strands in the same sense. The height winds by around the circumference, so write with periodic . The classical gradient action is .
Without through-strands, winding loops require the seam charges. The long-cylinder loop partition function has the factor . In the through-strand sector, loops wrapping around the circumference are forbidden: they would cross a strand. Its ordinary periodic height fluctuations therefore supply the oscillator factor . Dividing by the no-strand partition sum gives
This derives both the winding cost and the background subtraction. The formula is for the specified nonzero-strand sector; setting would remove the topological obstruction and restore winding loops, so its negative extrapolated value is not the identity dimension.
For critical Ising FK boundaries, gives and dense . Thus
The final relation identifies the two-leg passage probability with the fractal dimension of these FK boundaries. It does not assign to the Ising spin or energy: those dimensions are and one. Geometric Ising spin-domain walls also have a different loop description. The same thermodynamic model supports several distinct geometric observables.
Summary
The planar FK identity fixes , and oriented turning phases fix the height background charge. Cylinder seams and the dense screening branch are essential inputs to the continuum Gaussian representation. A through-strand calculation then derives the two-leg dimension with its vacuum subtraction; it is not a statement about arbitrary height or vortex gases.
Exercises
1. Percolation hulls. Apply the same dense construction at and calculate , the two-leg dimension and hull dimension.
Solution
The loop fugacity is one, so and . Substitution gives and . The hull dimension is . Central charge zero does not make percolation connectivity trivial: its normalized partition sum is one, but its selected interface sectors and correlation functions remain nontrivial.
2. Forgetting the seam. For Ising FK loops, compute the erroneous central charge and two-leg dimension obtained by treating every cylinder sector as an ordinary neutral Gaussian boson at .
Solution
Without the seam the no-strand vacuum has . The oscillator factors cancel in , leaving , rather than . The discrepancy is . Microscopically the missing seam assigns weight two to every noncontractible loop instead of . Thus the error has a concrete finite-boundary origin; it cannot be repaired by rescaling the height after the observable has been chosen.
References
- J. Cardy, Conformal Field Theory and Statistical Mechanics, v1, §§6.1–6.2, printed pp. 24–28: loop orientation, unbounded heights, cylinder endpoint charges and screening. The local Wick derivation above fixes our normalization; the printed Eq. (24) omits a factor two relative to its preceding Gaussian dimension and subsequent screening result.
- J. Cardy, SLE for Theoretical Physicists, v2, §2.4 and §2.4.2, Eqs. (8)–(13), printed pp. 11–13: Gaussian limit and the through-strand cylinder calculation. Its turn parameter obeys ; the square-medial construction and Euler normalization are derived here.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.