BKT Renormalization-Group Equations
Small vortex pairs act as polarizable dipoles. Removing them changes the stiffness seen by larger pairs, which in turn changes whether vortices are relevant. This feedback produces a line of algebraic phases, a separatrix and an exponentially large crossover length rather than an ordinary critical power law.
Preparation: The neutral vortex gas and a momentum-shell or real-space RG. We increase the length cutoff ; this infrared flow has the opposite direction to a renormalization-scale flow.
Integrating one shell of dipoles
Use and a dimensionless fugacity per unit vortex, with measure and hard-core separation . Keep external, widely separated vortex charges at , and define
Core and outer-boundary terms are regulated as in the neutral gas. An inserted dipole has charge at and at . Its coupling to the external charges contributes
At order , integrate its separation over . The external-field-independent term shifts the free energy and the linear term averages to zero. The quadratic term changes the logarithm of the partition function by
The angular average is , and the radial shell is
Consequently . Since the effective action is reduced by this logarithm, screening lowers :
This derivation fixes the coefficient for the declared gas measure. It assumes external fields vary slowly over a dipole and works to the first nontrivial fugacity order. Core-overlap corrections, higher multipoles and higher fugacity powers lie beyond this truncation. A constant rescaling of would change the numerical coefficient.
Rescaling the vortex weight
For neutral unit charges, . After changing the cutoff to , the position measures provide while the logarithmic interaction provides . Thus the weight per vortex rescales as :
Equivalently, the vortex operator has Gaussian scaling dimension . These are the normalization of Nelson and Kosterlitz's Eqs. (6)–(8). Tong §4.4.3 explains the phase portrait with a positive scheme-dependent coefficient; the explicit shell calculation above supplies that coefficient here.
At every is a fixed point. For , a sufficiently small fugacity decreases and the infrared theory has algebraic correlations with . For , vortices grow. A trajectory that reaches a chosen small exit fugacity has left the most accurate part of the expansion. Continuing the two displayed beta functions to does not produce a reliable high-temperature stiffness or equation of state.
The separatrix and an exact check of the truncated flow
Within the displayed two-equation truncation, divide the equations to obtain
Thus is constant. It is an invariant of these leading equations, not an exact all-order invariant of the XY model. With , the incoming critical trajectory obeys
The branch matters: the same invariant on the low- side flows away from the fixed point. The companion preserves while integrating the full leading equations and repeats the integration at tighter tolerances. It stops the disordered flows at , and tests changing this exit criterion.
For example, choose and on the disordered side. The numerical exit times are:
| at | ||
|---|---|---|
The last column approaches . Tightening the integration tolerances changes these times by less than ; this controls the ODE solution, not the higher-order fugacity corrections omitted from the beta functions.
Integrating the essential singularity
Define and . The leading equations become , . Near the endpoint , their normal form is
Dots denote . The incoming separatrix is , on which . On the disordered side write . Then , which integrates exactly:
Take a fixed small and a fixed small exit fugacity . The exit coordinate is . As , both arctangents approach opposite endpoints, so
A generic analytic microscopic path through the separatrix has , with and . This yields the leading essential singularity
The constant and the microscopic length normalization depend on matching. The normal form gives in its coordinates; higher-order flows can change subleading terms. Connecting the exit scale to the physical disordered correlation length assumes no additional divergent scale after leaving the dilute region. A path tangent to the separatrix need not have the generic linear relation .
Left: leading gas flows start at ; the disordered curve stops at . Right: the normal form with and approaches . The plotted length corresponds to the chosen fugacity cutoff within the dilute-flow approximation.
Summary
Dipole polarization fixes the screening sign and, for the specified measure, the coefficient . Vortex rescaling completes the coupled flow. Integrating its near-separatrix normal form explains why diverges as and why finite-size crossovers can be exceptionally slow.
Exercises
1. Critical finite-size stiffness
Derive the leading logarithmic approach of the local stiffness to on the incoming separatrix.
Solution
With , , so . Since ,
The correction is positive and decays logarithmically. The integration constant is nonuniversal; omitted higher-order beta functions also generate subleading logarithms. For the fully equilibrated torus helicity estimator, a separate winding-sector conversion is required, as in the jump calculation.
2. A changed exit convention
For , compare the small- exit times at and . Does this alter the leading essential singularity?
Solution
The constant terms are and , respectively. The smaller exit fugacity is reached five RG-time units earlier asymptotically, so the corresponding exit lengths differ by a factor . Both have the same leading divergence. Changing the exit criterion rescales the microscopic prefactor while preserving the leading essential singularity for these generic paths.
References
- David R. Nelson and J. M. Kosterlitz, “Universal Jump in the Superfluid Density of Two-Dimensional Superfluids”, Physical Review Letters 39 (1977), 1201–1205, Eqs. (6)–(10), doi:10.1103/PhysRevLett.39.1201.
- David Tong, Statistical Field Theory, §4.4.3, printed pp. 133–139, Eqs. (4.43)–(4.48), author's notes.