Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    POVMs, Instruments, and Measurement Records

    Two devices make the same unsharp ZZ measurement. The second also flips the qubit after a minus result. Give either device the state ∣0⟩|0\rangle and set the measurement strength to 0.40.4. Both write a minus with probability 0.30.3. Read ZZ immediately afterward on those minus trials: the first device returns +1+1 with certainty and the second returns −1-1 with certainty. How can their first records agree for every input yet predict different second records?

    Preparation: Channel from a controlled pointer rotation and partial traces. Logarithms are natural, so entropies are in nats.

    Effects predict outcomes; instruments predict what follows

    For outcomes rr, a positive-operator-valued measure consists of effects

    Er≥0,∑rEr=I,pr=tr⁡(ρEr).E_r\geq0,\qquad \sum_rE_r=I,\qquad p_r=\operatorname{tr}(\rho E_r).

    An instrument gives completely positive, trace-nonincreasing maps Ir\mathcal I_r. Its sum E=∑rIr\mathcal E=\sum_r\mathcal I_r is a channel, and

    Ir(ρ)=∑αMrαρMrα†,Er=∑αMrα†Mrα.\mathcal I_r(\rho)=\sum_\alpha M_{r\alpha}\rho M_{r\alpha}^\dagger, \qquad E_r=\sum_\alpha M_{r\alpha}^\dagger M_{r\alpha}.

    When pr>0p_r>0, the conditional state is ρr=Ir(ρ)/pr\rho_r=\mathcal I_r(\rho)/p_r. Keeping the classical record produces the joint state

    ρRQ=∑r∣r⟩⟨r∣⊗Ir(ρ).\rho_{RQ}=\sum_r |r\rangle\langle r|\otimes\mathcal I_r(\rho).

    Discarding RR gives E(ρ)\mathcal E(\rho). The normalization in ρr\rho_r makes the conditioned update nonlinear; the unnormalized instrument and its average remain linear.

    Multiplying a Kraus operator on the left by an outcome-dependent unitary preserves its effect. It generally changes the output state. Thus choosing the positive square root Mr=ErM_r=\sqrt{E_r} is one implementation, not information already contained in the POVM.

    One unsharp measurement, two disturbances

    Measure qubit AA with strength 0≤η≤10\leq\eta\leq1:

    E±=I±ηZ2,p=1+η2,q=1−η2,κ=2pq=1−η2.E_\pm=\frac{I\pm\eta Z}{2},\qquad p=\frac{1+\eta}{2},\quad q=\frac{1-\eta}{2},\quad \kappa=2\sqrt{pq}=\sqrt{1-\eta^2}.

    Compare the two single-Kraus instruments

    M+=(p00q),M−=(q00p),N+=M+,N−=XM−.M_+=\begin{pmatrix}\sqrt p&0\\0&\sqrt q\end{pmatrix},\quad M_-=\begin{pmatrix}\sqrt q&0\\0&\sqrt p\end{pmatrix}, \qquad N_+=M_+,\quad N_-=XM_-.

    Both satisfy completeness and Nr†Nr=Mr†Mr=ErN_r^\dagger N_r=M_r^\dagger M_r=E_r. The second device applies a bit flip after the minus result. This is a local feedback operation whose record can subsequently be erased.

    Start from ∣Φ+⟩=(∣00⟩+∣11⟩)/2|\Phi^+\rangle=(|00\rangle+|11\rangle)/\sqrt2. Each outcome has probability 1/21/2. For the first instrument, discarding the record yields, in the order 00,01,10,1100,01,10,11,

    ρM=12(100κ00000000κ001).\rho_M=\frac12 \begin{pmatrix}1&0&0&\kappa\\0&0&0&0\\0&0&0&0\\\kappa&0&0&1\end{pmatrix}.

    Partial transposition on BB gives eigenvalues 1/21/2, 1/21/2, κ/2\kappa/2 and −κ/2-\kappa/2. Hence its negativity is NM=κ/2\mathcal N_M=\kappa/2.

    For the feedback instrument,

    ρN=12(p00pq0ppq00pqq0pq00q).\rho_N=\frac12 \begin{pmatrix} p&0&0&\sqrt{pq}\\ 0&p&\sqrt{pq}&0\\ 0&\sqrt{pq}&q&0\\ \sqrt{pq}&0&0&q \end{pmatrix}.

    This state is separable. Define ∣a±⟩=p ∣0⟩±q ∣1⟩|a_\pm\rangle=\sqrt p\,|0\rangle\pm\sqrt q\,|1\rangle and ∣±⟩=(∣0⟩±∣1⟩)/2|\pm\rangle=(|0\rangle\pm|1\rangle)/\sqrt2. Direct expansion gives

    ρN=12∑s=±∣as⟩⟨as∣⊗∣s⟩⟨s∣.\rho_N=\frac12\sum_{s=\pm}|a_s\rangle\langle a_s|\otimes|s\rangle\langle s|.

    At η=0.4\eta=0.4, the first output has negativity 0.45825756950.4582575695, while the second has zero. Their ZZZZ correlations are respectively one and zero. The probability distributions of their records are nevertheless identical for every input state, not only this Bell input.

    For the two-readout example above, M−∣0⟩=q ∣0⟩M_-|0\rangle=\sqrt q\,|0\rangle and N−∣0⟩=q ∣1⟩N_-|0\rangle=\sqrt q\,|1\rangle. The two nonzero joint probabilities on that branch therefore refer to opposite second outcomes, even though both have weight qq. For a longer string of measurements the trajectory rule multiplies the actual Kraus operators in time order.

    What is lost when the record is erased?

    Each conditioned Bell output is pure and has Schmidt weights p,qp,q. The feedback changes it only by a unitary on AA, so both instruments have the same conditional entanglement entropy

    h(p)=−plog⁡p−qlog⁡q=0.6108643021(η=0.4).h(p)=-p\log p-q\log q=0.6108643021 \qquad (\eta=0.4).

    The difference arises when differently oriented branches are mixed. It cannot be inferred from the POVM alone.

    Neither local instrument changes Bob's unconditional marginal: ρB=I/2\rho_B=I/2. In general, for every observable BB on the second subsystem, Kraus completeness gives

    ∑rtr⁡ ⁣[(Mr⊗I)ρ(Mr†⊗I)(I⊗B)]=tr⁡[ρ(I⊗B)].\sum_r\operatorname{tr}\!\left[(M_r\otimes I)\rho(M_r^\dagger\otimes I)(I\otimes B)\right] =\operatorname{tr}[\rho(I\otimes B)].

    Conditional Bob states can differ. Bob needs the record to sort those subensembles; their existence does not supply a message without communication. Relativistic field theory adds the separate requirement that a proposed instrument actually arise from an admissible localized coupling, developed in causal probe measurements.

    Summary

    A POVM fixes outcome probabilities. An instrument also fixes disturbance, and retaining the record differs physically from averaging over it. The two exact instruments above have the same effects and conditional entanglement but different unconditional entanglement.

    Exercises

    1. At η=0\eta=0, what does each device do? Can an uninformative record accompany disturbance?
    Solution

    Both effects are I/2I/2. The first instrument has M±=I/2M_\pm=I/\sqrt2, so its average channel is the identity. The feedback channel is (ρ+XρX)/2(\rho+X\rho X)/2, which can destroy entanglement with a reference even though the record is a fair coin independent of the input. For the Bell input its output is the equal mixture of Φ+\Phi^+ and Ψ+\Psi^+, with the separable decomposition above at p=q=1/2p=q=1/2.

    1. At η=1\eta=1, find the average single-qubit channels and explain why the records still agree.
    Solution

    Now M+=∣0⟩⟨0∣M_+=|0\rangle\langle0| and M−=∣1⟩⟨1∣M_-=|1\rangle\langle1|. Their sum channel removes the off-diagonal elements in the ZZ basis. In contrast, N+=∣0⟩⟨0∣N_+=|0\rangle\langle0| and N−=∣0⟩⟨1∣N_-=|0\rangle\langle1|, so the feedback channel resets every normalized input to ∣0⟩⟨0∣|0\rangle\langle0|. Both record the same two initial populations. Resetting the output does not alter those already generated probabilities.

    References

    • Fewster and Verch, Quantum fields and local measurements, §3.3, Eqs. (3.23)–(3.29), for instruments, conditioning and nonselective evolution in the field–probe setting. The two finite instruments and their spectra above are calculated explicitly here.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.