- Home
- Library
- Quantum Information in Field Theory
- Multiscale Circuits and the Cost of State Preparation
- Mixed States and Purification Complexity
Mixed States and Purification Complexity
A thermal oscillator admits many pure states with the same physical marginal. Preparing the familiar thermofield state therefore supplies a cost, but it need not solve the least-cost preparation problem. Here one ancillary oscillator is enough to exhibit the difference: an ancillary squeeze lowers the cost while leaving every physical observable unchanged.
Preparation: Gaussian-state complexity and Gaussian covariance matrices. We use , covariance equal to half the anticommutator, and natural logarithms.
Three preparation questions
Fix a pure reference on the physical system and an ancilla . A circuit that prepares a specified solves a pure-state task. Discarding then prepares . Minimizing over admissible purifications instead defines
The ancilla, its initial state, available gates and cost of discarding belong to this definition. Direct noisy-channel preparation is another problem unless its environment and control costs have been matched to this circuit model. A pure reference cannot become mixed under a unitary acting on alone.
We charge the unitary path on , fix one initially uncorrelated ancillary oscillator, and assign no additional cost to the final trace. We restrict both states and paths below. This is the real Gaussian purification problem studied in Caceres et al., §§2.3 and 7.5, expressed using covariances rather than inverse wavefunction widths.
All purifications in the declared real family
The target is a centered thermal oscillator with frequency :
For two oscillators, order the quadratures as and restrict the pure covariance to
This excludes position-momentum correlations. It is a genuine pure covariance: with , it obeys .
Write . Matching the physical marginal requires
Thus is free and . The determinant is positive. These equations describe every covariance in the stated real, one-ancilla family. The two signs of have identical eigenvalues and costs for the isotropic reference below.
Fix the reference frequency and set
Parameterize . Choosing the positive correlation sign gives
Changing changes only the purification, not .
Minimize the circuit before minimizing the purification
Allowed Gaussian transformations act as and , with in . For , choose the unpenalized speed
The endpoint satisfies . The Euclidean speed of the logarithms of the singular values of is at most . Integrating gives a lower bound on the length. The path
attains it, so for each purification
The trace here is of the squared matrix logarithm. Equal gate weights and the isotropic reference are essential to this argument; it is not a result for arbitrary penalties.
The determinant and trace of imply eigenvalues , where
Consequently the remaining optimization is one dimensional:
This agrees with the squared cost in Caceres et al., Eq. (7.21). Their matrix is the inverse of and their shifted squeezes have the opposite sign; the squared eigenvalue logarithms agree.
For a mixed target, , direct differentiation gives
The cost grows without bound at large . Strict convexity therefore makes its stationary point the unique global minimum within this family. A numerical root solves the remaining equation; the convexity proof, rather than a successful optimizer alone, establishes globality.
A thermal state whose thermofield preparation costs more
The fixed thermofield choice uses equal oscillator frequencies on both sides and corresponds to . In number states it is
Choose , , and , so . The stationary point and target-preserving covariance are
The optimized cost is , compared with . Both prepare precisely the same thermal marginal. The improvement is an ancillary preparation choice, not cooling of the physical state.
Holding this target fixed while changing the reference gives:
| Optimized | Fixed TFD | |
|---|---|---|
The retained calculation in examples/quantum-information/purification-complexity/ checks the stationary root at 70-digit precision, the reduced covariance, full Gaussian purity, matrix eigenvalue cost and actual circuit endpoint. It also checks the pure and matched-reference limits. No optimization over additional ancillas, complex Gaussian states or non-Gaussian gates has been performed. These larger families could change the result.
Summary
For a fixed one-ancilla real Gaussian family, isotropic reference and Frobenius gate cost, purification complexity reduces to a strictly convex scalar minimization. The thermofield state is a candidate and is optimal when its oscillator frequency matches the reference; generally an ancillary squeeze lowers the cost. The target density matrix alone does not determine a preparation cost.
Exercises
1. Two exact limits. Find the minimum for a pure target and for a mixed target with . Explain what happens to the ancilla.
Solution
For , and the squared cost becomes . The minimum is , with cost . The off-diagonal covariance vanishes and : the ancilla remains in its reference state. Choosing the fixed TFD value would unnecessarily squeeze an uncorrelated ancilla and give .
For and , the cost is even in and strictly convex, so . Its value is
The ancilla is entangled with the physical mode. Equal reference and physical frequencies make the symmetric thermofield preparation optimal in this family.
2. Extra free resources. Suppose a second ancilla is admitted. Under what conditions is the old answer an upper bound, and why does this give no monotonicity under arbitrary quantum channels?
Solution
Extend the reference by an uncorrelated ancillary reference state, retain every old gate with the same cost, and allow the new ancilla to remain idle. Each old path is then still feasible at its old cost, so the enlarged infimum cannot exceed the old minimum. This argument fails if the new model changes the reference or charges additional compulsory costs.
A general channel can consume an external pure state or discard information. Unless these resources and their implementation are charged by the same preparation model, applying the channel is not a free operation in this optimization. Set inclusion of purification families therefore implies no universal decrease of complexity under channels.
References
- Caceres, Elena, Shira Chapman, Josiah D. Couch, Juan P. Hernandez, Robert C. Myers, and Shan-Ming Ruan. “Complexity of Mixed States in QFT and Holography.” JHEP 03 (2020), 012. arXiv:1909.10557v1, §§2.1, 2.3 and 7.5, especially Eqs. (2.11)–(2.13), (2.42), and (7.21)–(7.23).
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.