Skip to content
QFT.org

Search QFT.org

Enter a word or phrase.

    You can also browse the main navigation and chapter contents.

    Reconstructing Spectra from Euclidean Data

    Which spectral features are determined by a finite noisy Euclidean correlator, and which are supplied by the reconstruction rule? We calculate a synthetic example with known spectral truth. Several reconstructions fit the data well but disagree on a narrow feature, and a small propagated statistical error can coexist with substantial regularization bias.

    Preparation: ill-conditioned inversion, regularized least squares and smeared spectra.

    Specify a forward problem that can be checked

    Use a zero-temperature positive spectral channel,

    C(τ)=∫04dE s(E)e−Eτ,s(E)≥0,∫04s(E)dE=1.C(\tau)=\int_0^4 dE\,s(E)e^{-E\tau}, \qquad s(E)\geq0,\qquad \int_0^4s(E)dE=1.

    Compact support and unit normalization define this benchmark; they are not generic QFT sum rules. For a connected Hermitian channel in the site's convention, the positive-frequency commutator density is ρ(E)=2πs(E)\rho(E)=2\pi s(E). No finite-temperature kernel is being approximated by this Laplace kernel.

    The truth is an equal mixture of triangular peaks centered at 1.71.7 and 2.32.3, each with half-width a=0.15a=0.15. A normalized triangle centered at cc is a−1max⁡(1−∣E−c∣/a,0)a^{-1}\max(1-|E-c|/a,0), and its exact transform is

    Cc(τ)=e−cτ[sinh⁡(aτ/2)aτ/2]2.C_c(\tau)=e^{-c\tau} \left[\frac{\sinh(a\tau/2)}{a\tau/2}\right]^2.

    This follows by writing the triangle as the convolution of two uniform distributions. We use 2424 times τi=0.15i\tau_i=0.15i, with i=1,…,24i=1,\ldots,24, and independent Gaussian noise of known standard deviation 10−3C(τi)10^{-3}C(\tau_i), with retained seed 731731. The exact forward kernel is reused from the inspected Library companion. These are synthetic data, not a hadronic spectrum or a reproduction of a QCD ensemble.

    Compare two explicit inverse rules

    Represent the density on 160160 midpoint nodes in [0,4][0,4]. With spacing hh, the forward matrix is Kij=he−τiEjK_{ij}=h e^{-\tau_iE_j}. Whiten each row by its noise standard deviation σi\sigma_i, giving Aij=Kij/σiA_{ij}=K_{ij}/\sigma_i and bi=Ciobs/σib_i=C_i^{\rm obs}/\sigma_i. The whitened data have unit noise covariance. Although the input density has unit integral, neither fit below enforces a unit-area constraint.

    The first rule uses a truncated singular-value decomposition. If A=UΣVTA=U\Sigma V^T, retain rr singular directions:

    s^r=∑a=1rvauaTbσa.\widehat s_r=\sum_{a=1}^r v_a\frac{u_a^Tb}{\sigma_a}.

    The second minimizes a nonnegative penalized least-squares objective,

    ∥As−b∥2+α2∥D2s∥2,sj≥0,\lVert A s-b\rVert^2+\alpha^2\lVert D_2s\rVert^2, \qquad s_j\geq0,

    where D2D_2 is the unscaled second-difference matrix on this declared grid. The number α\alpha is therefore grid dependent. Positivity and smoothness are additional information; a good fit does not demonstrate that their implied peak shape is measured.

    For a Gaussian kernel WW normalized to unit area on [0,4][0,4], estimate the weighted density ∫04W(E)s(E) dE\int_0^4 W(E)s(E)\,dE. The broad kernel has center 22 and standard-deviation parameter 0.50.5. The narrow kernel is centered on the first peak at 1.71.7 with parameter 0.150.15. Their exact smeared densities are 0.6633070.663307 and 1.2303811.230381.

    MethodFit χ2/24\chi^2/24Broad targetNarrow target
    SVD, r=6r=61.2670.591860.68325
    SVD, r=8r=80.6270.530691.29299
    Positive smooth, α=1\alpha=10.9080.679210.98644
    Positive smooth, α=10\alpha=100.9400.672670.96570
    Positive smooth, α=100\alpha=1001.0090.679130.92004

    The fit statistic is divided by the number of data, not by a claimed effective number of degrees of freedom. The eighth-rank inversion contains substantial negative spectral weight; the nonnegative reconstructions exclude that behavior by construction. Increasing to rank ten improves the fit further while producing enormous oscillations. The full retained output includes these deliberately poor alternatives.

    Known two-peak spectrum and three reconstructions above their small Euclidean fit residuals, showing that similar data fits need not resolve the same spectral features.

    Retained reconstructions from the same noisy data. The lower panel measures residuals in units of the known noise standard deviation σ\sigma. Small residuals coexist with different spectral shapes in the upper panel.

    A statistical error is not a resolution error

    For a fixed linear reconstruction s^=Bb\widehat s=Bb and target vector ff, the estimate is fTBbf^TBb. Whitened noise has identity covariance, so its standard deviation is ∥fTB∥\lVert f^TB\rVert. Its expectation is determined by the actual resolution row fTBAf^TBA, which need not equal the requested target fTf^T.

    At rank six, the broad target has propagated standard error 0.002940.00294 but noiseless reconstruction bias −0.06692-0.06692. The narrow target has standard error 0.003170.00317 and bias −0.55502-0.55502. Tiny statistical error bars would therefore give a severely misleading impression of precision. At rank eight the broad standard error grows to 0.087820.08782 while its noiseless bias falls to about −0.00913-0.00913: resolving more directions amplifies noise.

    For this known spectrum the RMS error combines the two effects in quadrature. For the broad target it grows from 0.06700.0670 at rank six to 0.08830.0883 at rank eight. For the narrow target it falls from 0.5550.555 to 0.5220.522. Thus the preferred rank can change with the observable, even using identical data. Ten thousand independent noise realizations verify the rank-six linear-rule standard errors to within 1.5%1.5\%. The known triangle's midpoint forward quadrature on 320320 nodes differs from its exact transform by at most 0.0850.085 of a data standard deviation. Grid discretization is checked separately from the exact generation of the noisy data. The positive nonlinear method's table entries are single realizations, with no uncomputed confidence intervals implied.

    Formulate the result at a defensible resolution

    Hansen, Lupo and Tantalo propose choosing a target smearing function first and approximating it using the Euclidean kernel basis. Their §III, Eqs. (24)–(28), makes the target-versus-achieved resolution distinction explicit. One can hold that target fixed while comparing volumes; taking a zero-width limit before the infinite-volume limit encounters the discrete finite-volume spectrum. arXiv:1903.06476v2.

    Lupo and Tantalo's 2026 eigen-space analysis adds a truncation-based stability procedure and studies its combination with the earlier regulator. The authors also identify overly conservative or aggressive choices of truncation. Our elementary SVD experiment illustrates the competing errors, but does not implement their hybrid procedure or reproduce its QCD closure tests. §§III.2–IV, arXiv:2605.14652v1.

    A well-posed extension fixes a smeared physical target and measures its bias and coverage across spectra that violate the reconstruction's preferred shape: unequal weights, a threshold continuum, or an extra weak peak. Keep the noise covariance and parameter-selection rule fixed before testing those cases. If only broad integrals survive this challenge, report those integrals rather than a sharp resonance width.

    References

    Extract the noisy correlators and reconstruction code (ZIP) and run python3 examples/research/matter-computation/spectral.py. The retained data, reconstructions, singular values, targets, biases and noise checks are in spectral-results.json.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.