Which spectral features are determined by a finite noisy Euclidean correlator, and which are supplied by the reconstruction rule? We calculate a synthetic example with known spectral truth. Several reconstructions fit the data well but disagree on a narrow feature, and a small propagated statistical error can coexist with substantial regularization bias.
Preparation: ill-conditioned inversion, regularized least squares and smeared spectra.
Specify a forward problem that can be checked
Use a zero-temperature positive spectral channel,
Compact support and unit normalization define this benchmark; they are not generic QFT sum rules. For a connected Hermitian channel in the site's convention, the positive-frequency commutator density is . No finite-temperature kernel is being approximated by this Laplace kernel.
The truth is an equal mixture of triangular peaks centered at and , each with half-width . A normalized triangle centered at is , and its exact transform is
This follows by writing the triangle as the convolution of two uniform distributions. We use times , with , and independent Gaussian noise of known standard deviation , with retained seed . The exact forward kernel is reused from the inspected Library companion. These are synthetic data, not a hadronic spectrum or a reproduction of a QCD ensemble.
Compare two explicit inverse rules
Represent the density on midpoint nodes in . With spacing , the forward matrix is . Whiten each row by its noise standard deviation , giving and . The whitened data have unit noise covariance. Although the input density has unit integral, neither fit below enforces a unit-area constraint.
The first rule uses a truncated singular-value decomposition. If , retain singular directions:
The second minimizes a nonnegative penalized least-squares objective,
where is the unscaled second-difference matrix on this declared grid. The number is therefore grid dependent. Positivity and smoothness are additional information; a good fit does not demonstrate that their implied peak shape is measured.
For a Gaussian kernel normalized to unit area on , estimate the weighted density . The broad kernel has center and standard-deviation parameter . The narrow kernel is centered on the first peak at with parameter . Their exact smeared densities are and .
| Method | Fit | Broad target | Narrow target |
|---|---|---|---|
| SVD, | 1.267 | 0.59186 | 0.68325 |
| SVD, | 0.627 | 0.53069 | 1.29299 |
| Positive smooth, | 0.908 | 0.67921 | 0.98644 |
| Positive smooth, | 0.940 | 0.67267 | 0.96570 |
| Positive smooth, | 1.009 | 0.67913 | 0.92004 |
The fit statistic is divided by the number of data, not by a claimed effective number of degrees of freedom. The eighth-rank inversion contains substantial negative spectral weight; the nonnegative reconstructions exclude that behavior by construction. Increasing to rank ten improves the fit further while producing enormous oscillations. The full retained output includes these deliberately poor alternatives.
Retained reconstructions from the same noisy data. The lower panel measures residuals in units of the known noise standard deviation . Small residuals coexist with different spectral shapes in the upper panel.
A statistical error is not a resolution error
For a fixed linear reconstruction and target vector , the estimate is . Whitened noise has identity covariance, so its standard deviation is . Its expectation is determined by the actual resolution row , which need not equal the requested target .
At rank six, the broad target has propagated standard error but noiseless reconstruction bias . The narrow target has standard error and bias . Tiny statistical error bars would therefore give a severely misleading impression of precision. At rank eight the broad standard error grows to while its noiseless bias falls to about : resolving more directions amplifies noise.
For this known spectrum the RMS error combines the two effects in quadrature. For the broad target it grows from at rank six to at rank eight. For the narrow target it falls from to . Thus the preferred rank can change with the observable, even using identical data. Ten thousand independent noise realizations verify the rank-six linear-rule standard errors to within . The known triangle's midpoint forward quadrature on nodes differs from its exact transform by at most of a data standard deviation. Grid discretization is checked separately from the exact generation of the noisy data. The positive nonlinear method's table entries are single realizations, with no uncomputed confidence intervals implied.
Formulate the result at a defensible resolution
Hansen, Lupo and Tantalo propose choosing a target smearing function first and approximating it using the Euclidean kernel basis. Their §III, Eqs. (24)–(28), makes the target-versus-achieved resolution distinction explicit. One can hold that target fixed while comparing volumes; taking a zero-width limit before the infinite-volume limit encounters the discrete finite-volume spectrum. arXiv:1903.06476v2.
Lupo and Tantalo's 2026 eigen-space analysis adds a truncation-based stability procedure and studies its combination with the earlier regulator. The authors also identify overly conservative or aggressive choices of truncation. Our elementary SVD experiment illustrates the competing errors, but does not implement their hybrid procedure or reproduce its QCD closure tests. §§III.2–IV, arXiv:2605.14652v1.
A well-posed extension fixes a smeared physical target and measures its bias and coverage across spectra that violate the reconstruction's preferred shape: unequal weights, a threshold continuum, or an extra weak peak. Keep the noise covariance and parameter-selection rule fixed before testing those cases. If only broad integrals survive this challenge, report those integrals rather than a sharp resonance width.
References
- M. Hansen, A. Lupo and N. Tantalo, On the extraction of spectral densities from lattice correlators, §§I, III–IV and Appendix B: finite-volume limits, target kernels and synthetic closure tests.
- A. Lupo and N. Tantalo, Extraction of spectral densities from lattice correlators: decoupling signal from noise, §§III.2–IV and Appendix A: truncation sensitivity and the order of limits.
Extract the noisy correlators and reconstruction code (ZIP) and run python3 examples/research/matter-computation/spectral.py. The retained data, reconstructions, singular values, targets, biases and noise checks are in spectral-results.json.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.