- Home
- Research
- Amplitudes and Effective Field Theory
- From Matching to a Precision Prediction
From Matching to a Precision Prediction
At what energy does resolving a heavy virtual particle matter for light-particle scattering? We answer at one loop by comparing a full scalar theory with its low-energy expansion at the same scattering angle. The naively leading correction cancels on shell. Its absence leads to a measurable pattern in the error as the collision energy is varied.
Preparation: Threshold matching and the one-loop reconstruction project. All couplings below are defined in modified minimal subtraction with .
Choose a model in which both sides can be calculated
Let be a real light scalar and a real heavy scalar:
Take positive weak couplings and tune the renormalized light pole mass to zero. The heavy tadpole makes this a nontrivial mass tuning, not a symmetry-protected hierarchy. The parameters are dimensionless; has mass dimension one. At the order considered, does not enter four-light-particle scattering, and replacing the heavy renormalized mass by its pole mass affects the answer only at higher order.
At nonforward massless kinematics, . There are light and heavy bubble diagrams, each with symmetry factor . Define
The full-theory amplitude through one loop is
Inside one-loop terms, using and in place of the running couplings changes only two-loop terms. The light bubbles are infrared finite at the fixed nonzero invariants used here. Forward scattering would require separate treatment of the massless channel.
Match the local terms, including the threshold logarithm
The Taylor coefficients follow by integrating powers of :
The constant heavy contribution fixes the EFT quartic coupling:
At , this one-loop threshold correction vanishes in this scheme. The remaining heavy-particle effects enter through higher-derivative terms and through the change in running across threshold.
The term linear in cancels on shell because their sum is zero. The first nonzero power correction to this particular amplitude is consequently
followed by . This cancellation uses the on-shell condition for this massless four-point observable.
Run below the threshold and check matching-scale independence
The one-loop beta functions relevant to this calculation are
Differentiating the threshold relation subtracts , exactly the difference. The positive beta functions also cancel the scale derivative of the negative tree amplitude against the bubble logarithms. This checks the matching sign and the factor of three from crossing channels.
At fixed one-loop order, writing gives
Solving the one-loop flow equation without expanding instead sums leading logarithms:
This is a useful higher-order improvement when the logarithm is large, but it is not a full two-loop calculation. For and , the fixed-order value is , while the resummed value is . Their difference measures a known subset of higher-order terms, not a rigorous total error bound.
Compare orders at a physical scattering angle
Set , and , corresponding to a right-angle center-of-mass collision. Write . Compare the exact heavy bubble at one loop with its local expansion through , while retaining the same light loop and running in each prediction.
| No power term | Through | Through | |
|---|---|---|---|
| 0.1 | |||
| 0.25 | |||
| 0.5 | |||
| 1 |
Each entry is for the complex one-loop amplitudes. The small- leading behaviors are , and respectively. The pair-production branch point is at ; the table remains below it, but is already a much weaker hierarchy.
For an identical final state integrated over the full solid angle,
At next-to-leading order one must expand the numerator as , where , rather than retain the entire square of the one-loop correction. At , the three corresponding rate errors are , and . These compare consistently truncated rates, not an uncomputed exact cross section.
What the benchmark resolves, and what it leaves open
Changing the evaluation scale among , , and leaves the retained full amplitude unchanged when couplings and logarithms are expanded consistently to one loop. Freezing at while evaluating the light loop at fails that test: at it shifts the amplitude by , much larger than the power error. Conversely, exact scale cancellation at a fixed order cannot imply zero perturbative uncertainty.
A next calculation can retain a nonzero light mass, where the linear power term no longer vanishes, or compute two-loop matching to compare the power error with a genuine higher-loop correction. Gauge theories add operator mixing and redundant-operator choices, but the same discriminant remains: reproduce an observable with shared light physics, vary the hierarchy, and separate the truncation in powers from the truncation in loops.
References
- A. V. Manohar, Introduction to Effective Field Theories, arXiv:1804.05863, §§5.5–5.7, especially Eqs.(5.23)–(5.26): matching as a difference of renormalized quantities, separation of scales and running. The portal model and coefficients on this page are derived explicitly rather than quoted as that source's toy model.
- The scalar-bubble reconstruction supplies the integral normalization and its independent cut check. The Library threshold calculation explains why mass-independent subtraction alone does not decouple heavy fields.
- Download the matching calculation and amplitude comparisons (ZIP). The script retains the exact parameter integral, local moments, both beta functions, matching-scale cancellation, and amplitude/rate comparisons.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.