    Comparing RG and Bootstrap Critical Exponents

    A comparison between renormalization-group and bootstrap exponents is meaningful only after both calculations refer to the same fixed point and the same operators. The useful outcome is an explanation of disagreement or agreement, including the different meanings of their uncertainties.

    We use the three-dimensional Ising universality class as a concrete example. The Reference exponent dictionary and Wilson–Fisher analysis provide the definitions and perturbative background.

    Translate dimensions into physical exponents

    Let σ\sigma be the leading odd scalar and ϵ\epsilon the even scalar coupled to the temperature-like relevant perturbation. At a local critical point in dd dimensions,

    η=2Δσ−(d−2),1ν=d−Δϵ.\eta=2\Delta_\sigma-(d-2),\qquad \frac1\nu=d-\Delta_\epsilon.

    The second relation follows because the coupling in t∫ddx ϵt\int d^dx\,\epsilon has RG eigenvalue yt=d−Δϵy_t=d-\Delta_\epsilon, and the scale at which tLyttL^{y_t} becomes order one is ξ∼∣t∣−1/yt\xi\sim|t|^{-1/y_t}. If the microscopic path varies several relevant couplings, its apparent exponent need not be this ν\nu.

    Chang et al., §1 and §5.2 report

    Δσ=0.518148806(24),Δϵ=1.41262528(29).\Delta_\sigma=0.518148806(24),\qquad \Delta_\epsilon=1.41262528(29).

    Direct conversion at d=3d=3 gives

    η=0.036297612(48),ν≃0.629970975(115).\eta=0.036297612(48),\qquad \nu\simeq0.629970975(115).

    For interval half-widths, the linearized conversion is δη=2 δΔσ\delta\eta=2\,\delta\Delta_\sigma and δν=ν2 δΔϵ\delta\nu=\nu^2\,\delta\Delta_\epsilon. The latter gives 1.15×10−71.15\times10^{-7}. The parentheses propagate the reported marginal dimension ranges. For a derived quantity depending on both dimensions, use their joint allowed region or covariance when supplied. Treating a narrow tilted island as an axis-aligned independent Gaussian can distort the uncertainty.

    Why a low-order estimate is not a competing precision result

    Write δ=4−d\delta=4-d, so the site's regulator notation has δ=2ϵreg\delta=2\epsilon_{\rm reg} at the same dimension. For the Ising fixed point, the leading expansions are

    ν=12+δ12+O(δ2),η=δ254+O(δ3).\nu=\frac12+\frac{\delta}{12}+O(\delta^2), \qquad \eta=\frac{\delta^2}{54}+O(\delta^3).

    Putting δ=1\delta=1 gives ν≃0.5833\nu\simeq0.5833 and η≃0.01852\eta\simeq0.01852. The discrepancy with the bootstrap values illustrates the truncation error when the expansion parameter is of order one.

    There is a subtler ambiguity at the same nominal order. Expanding 1/ν=2−δ/3+O(δ2)1/\nu=2-\delta/3+O(\delta^2) and evaluating its truncated reciprocal gives ν=0.6\nu=0.6 at δ=1\delta=1. The difference from 7/127/12 is formally higher order, but numerically material. Choosing the form that happens to lie closer to a known answer does not supply a controlled uncertainty.

    The six-loop analysis of Kompaniets and Panzer, §§V and VI.2 uses Borel resummation and parameter variations. Their quoted Ising values are η=0.0362(6)\eta=0.0362(6) and ν=0.6292(5)\nu=0.6292(5). These are retained as a specified published comparison, not described as the latest possible perturbative estimates. The difference in central ν\nu from the converted stress-tensor result is about 7.71×10−47.71\times10^{-4}, roughly 1.541.54 of that resummation's quoted uncertainty. A resummation systematic is not automatically a Gaussian standard deviation, so this ratio is diagnostic rather than a significance claim.

    What uncertainty belongs to which method?

    In perturbation theory, loop order, large-order information, analytic continuation and the resummation family matter. A plateau under one resummation parameter may coexist with a bias shared by the entire ansatz. Compare more than one observable and inspect known limits before treating stability as accuracy.

    In the bootstrap, the physical gap assumptions and numerical approximation determine an allowed region. Derivative-order convergence and smaller solver residuals address different questions. For example, the single-correlator calculation in the bootstrap research guide gives 1.23<Δϵ<1.551.23<\Delta_\epsilon<1.55 under its spectral assumptions. Converting the endpoints gives 100/177<ν<20/29100/177<\nu<20/29 if the Ising scaling limit realizes such a CFT. This broader interval is a conditional enclosure, while the narrow mixed-correlator values above are numerical determinations. Reehorst, Theorem 2, Eqs. (8.3)–(8.4)

    In Monte Carlo, irrelevant corrections, volume, thermalization and correlations between sizes dominate different regimes. A useful comparison translates the leading irrelevant scalar into ω=Δϵ′−d\omega=\Delta_{\epsilon'}-d, then asks whether the measured finite-size drift is compatible with that correction. A discrepancy in ν\nu can come from a poorly controlled correction amplitude before it comes from a new fixed point.

    A useful next calculation

    Reproduce a resummation from the published coefficients while withholding one known dimension or exponent from parameter selection. Predict it, and compare the result with a bootstrap region under independently justified spectral assumptions. For a less costly first project, quantify how truncating and then inverting an exponent changes a sequence of approximants; require that the chosen prescription recover the small-δ\delta expansion.

    The retained companion calculates the dimension-to-exponent conversion and synthetic crossing drift. It does not recompute six-loop diagrams, perform their resummation, or generate the Ising island. Download the dimension conversion and finite-size checks (ZIP).

    References

    • C.-H. Chang et al., “Bootstrapping the 3d Ising Stress Tensor,” arXiv:2411.15300v2, §1, §5.2 and Table 6.
    • M. V. Kompaniets and E. Panzer, “Minimally subtracted six loop renormalization of O(n)O(n)-symmetric ϕ4\phi^4 theory and critical exponents,” Physical Review D 96 (2017), 036016, arXiv:1705.06483v2, §§V and VI.2, Eq. (42).
    • M. Reehorst, “Region bounds, error margins and certified positivity in the numerical conformal bootstrap; Or the first mathematically rigorous bounds on the 3d Ising CFT critical exponents,” arXiv:2610.20701v1, §8.

    Scrollable formula. Use Left and Right arrow keys to reveal hidden content.

    Scrollable table. Use Left and Right arrow keys to reveal hidden columns.

    Scrollable figure. Use Left and Right arrow keys to reveal hidden content.