- Home
- Research
- Quantum Fields and Cosmology
- Infrared Dynamics in de Sitter Space
Infrared Dynamics in de Sitter Space
For a light scalar in de Sitter space, a perturbative variance grows with the number of e-folds and eventually departs from its leading expression. Does the interaction amplify the fluctuation or restrain it? A quartic spectator field gives an example where the first secular correction, the long-time distribution and a failure of Gaussian closure can all be calculated.
Preparation: De Sitter zero modes, secular effects, and stochastic inflation. The geometry here is prescribed, , and the scalar is minimally coupled with renormalized potential , where .
Identify the growing expansion parameter
A superhorizon free mode has . A coarse long field retaining modes below a fixed small fraction of gains variance
Start with negligible long-mode variance at . To leading infrared order, , with . This is a finite-time coarse observable; it is not the complete ultraviolet-renormalized coincident composite operator.
The overdamped quartic force gives
Using the free covariance and Wick's three contractions yields
where is the number of e-folds. The relative correction grows as . Its negative sign is the restoring effect of a positive quartic potential. Extending the truncated expression until the variance becomes negative would diagnose a failed approximation, not a negative physical variance.
A resummation with an explicit stationary distribution
At leading long-wavelength stochastic accuracy, diffusion and classical drift give
Setting the probability current to zero determines
The normalization and moments follow from the substitution on the positive half-line:
The companion independently integrates these moments at three couplings. Their normalized fourth moment is , appreciably different from the Gaussian value three. Matching only the variance would conceal this failure of a Gaussian closure. Download the equilibrium-moment quadrature (ZIP).
Indeed, the moment equation is
Replacing the fourth moment by predicts . This coefficient is approximately , about 15 percent below the stationary stochastic result. For a single field, weak coupling does not make this relative discrepancy vanish: both expressions have the same nonanalytic coupling dependence. A controlled large-component limit is a different approximation and must be identified separately.
Compare quantities before comparing “masses”
A useful static diagnostic is the inverse susceptibility scale defined by
This definition reproduces the leading light free-field variance when a small quadratic mass dominates. It does not automatically equal a pole mass, an unequal-time decay exponent, or every eigenvalue of the Fokker–Planck operator. Measuring the late-time autocorrelation requires that operator's nonzero spectrum; a static one-point distribution alone does not determine the full real-time response.
A separate check uses the constant field on the Euclidean four-sphere of radius . Its kinetic action vanishes and its volume is , so the quartic action is
Integrating the constant field with thus reproduces both equilibrium moments at leading order. The radius and the normalization of the quartic coupling fix the coefficient. Relaxation rates require time-dependent information beyond this integral. Beneke and Moch, §§3 and 7
What remains unresolved by this example
The coarse-graining scale, finite-time preparation, and corrections beyond leading infrared order must be controlled in a precision calculation. A massless minimally coupled free scalar has no ordinary de Sitter-invariant Fock vacuum for the full field; derivative observables and restricted algebras pose different questions. Adding a positive quartic interaction changes the infrared problem, so the interacting stationary distribution is not obtained by taking the free vacuum statement out of context.
The spectator calculation holds fixed. To infer a change in the expansion, one would need the renormalized stress and its gravitational response. The semiclassical guide specifies these quantities.
A viable next project compares the first nonzero stochastic relaxation rate with an independently computed long-distance two-point function at the same order in the light-field expansion. The fourth-moment discrepancy above supplies a useful negative benchmark for approximations that retain only a Gaussian effective mass.
References
-
M. Beneke and P. Moch, On "dynamical mass" generation in Euclidean de Sitter space, arXiv:1212.3058 (2012). §§3–4 and 7, the zero-mode integral and comparison with stochastic equilibrium.
-
A. A. Starobinsky and J. Yokoyama, Equilibrium State of a Massless Self-Interacting Scalar Field in the De Sitter Background (PDF), arXiv:astro-ph/9407016 (1994). §III, Eqs. (21)–(23), and §IV. Their quartic coupling in is related by .
-
The Library secular calculation retains the time-expansion derivation and explains why Gaussian closure misses more than one coefficient. The Research companion evaluates the equilibrium integrals.
Scrollable formula. Use Left and Right arrow keys to reveal hidden content.
Scrollable table. Use Left and Right arrow keys to reveal hidden columns.
Scrollable figure. Use Left and Right arrow keys to reveal hidden content.